LCD Display Online UPS Power Protection for networks(Centrio-LCD)
USD $1 - $2 /Piece
Min.Order:10 Pieces
Shenzhen Helior Technology Co., Ltd.
1-3kva single phase Rack &Tower design online ups (Sigma 1-3KVA)
20kva ups online protection for electronic device(Centrio DSP 6-20KVA)
20kva ups protection for electronic data storage(Centrio DSP 6-20KVA)
Online LCD Display UPS Power Protection for Data(Centrio-LCD)
Online UPS Power Protection for telecommunication system(Centrio-LCD)
LCD Display Online UPS Power Protection for networks(Centrio-LCD)
Outstanding Feature
CENTRIO UPS protects against:
1. Power failures
2. Voltage Amplitude Variations
3. Frequency Variations
4. Voltage Surges
5. Interference
6. Intermittent Voltage
Technical Specification
Model&Capacity
Model | C1KL | C1KSL | C2KL | C2KSL | C3KL |
Capacity | 1000VA/800W | 2000VA/1600W | 3000VA/2400W |
INPUT
Voltage | 80~300VAC | ||||
Frequency Range | 40Hz ~ 60Hz (Software adjustable) | ||||
Phase | Single phase with ground | ||||
Power Factor | equal or greater than0.95 |
OUTPUT
Voltage | 220/230/240VAC | ||||
Voltage Regulation | ± 2% | ||||
Frequency | 40~60Hz | ||||
( Synchronized Range) | |||||
Frequency | 50 ± 0.2 Hz | ||||
( Battery Mode) | |||||
Current Crest Ratio | 3:01 | ||||
Output Waveform | Pure Sinewave |
EFFICIENCY
Model | C1KL | C1KSL | C2KL | C2KSL | C3KL |
To AC Mode | 85% | 86% | |||
To Battery Mode | 83% | 83% |
BATTERY
Model | C1KL | C1KSL | C2KL | C2KSL | C3KL |
Battery Type | 12V/7.2Ah | Depending on the capacity of external batteries | 12V/7.2Ah | Depending on the capacity of external batteries | 12V/7.2Ah |
Numbers of Batteries | 3 | 8 | 8 | ||
Backup Time | more than6 minutes | more than10 minutes | more than6 minutes | ||
(Full Load) | |||||
Recharge Time | 5 hours to 90% | 5 hours to 90% | 5 hours to 90% | ||
Charging Current (Max.) | 1.0A | 7.0A | 1.0A | 8.0A | 1.0A |
Charging Voltage | 41.1Vdc ± 0.6V | 110Vdc ± 0.4V |
TRANSFER TIME
AC to DC | 0ms | ||||
Inverter to Bypass | 2.5ms (Typical ) |
CENTRIO protects PCs and networks:
*personal computers
*Workstations
*Networks, Server applications (LAN, WAN. etc)
*Telecommunication systems
Switch | Function | |
ON - Switch | 1. 1. Turn on UPS system:By pressing the ON-Switch “I” the UPS system is turned on. | |
1. 2. Deactivate acoustic alarm:By pressing this switch an acoustic alarm can be deactivated. | ||
| When mains power is normal, the UPS system “. It is then switched to Bypass and the inverter is off. At this moment, the output sockets are supplied with voltage via the bypass if the mains power is available.switches to Standby mode by pressing OFF-Switch “ | |
Display | Function |
LINE LED | 1. The green LINE LED lights up if mains voltage is applied to the UPS input. |
2. LINE LED blinks when the phase and neutral conductor have been reversed at the input of the UPS system. | |
3. If LINE LED and BATTERY-LED light up, the mains power supply is out of tolerance. | |
BATTERY LED | The orange-coloured BATTERY-LED lights up when the mains power has failed and the inverter is being powered by the batteries. |
BYPASS LED | The orange-coloured BYPASS LED lights up when the UPS system is supplying voltage provided by the mains power via the bypass. |
INVERTER LED | The green-coloured INVERTER LED lights up if the UPS system is supplying voltage provided by the mains power via the inverter. |
Customer Feedback
Our R&D team have tested your UPS, they are satisfied with the performance of the sample. All the test
results are complying with the specification. We are highly appreciated it. --- N. Raja (from Chennai, India)
We are quite impressive with the IGBT function of this UPS. We are now trying to apply this model on our
telecommunication systems. --- Robert Alles (from Munich, Germany)
Order information
Trade term: FOB Shenzhen / Hongkong
Delivery time: 7-21 days after confirmed the order
Packaging Detail:Standard export carton or OEM package
Warranty
1 years since the date of purchase
Warranty term
1. Under the terms of this warranty, if failure occurs under normal usage within warranty period, Helior Technology will provide free maintenance based on the proof-documents.
2. If Failure or damage occurs due to incorrect operation, wire connection, or any other mis-opeartions, Helior Technology will provide pay maintenance on charge basis.
More detailed info for family UPS & Inverter, please do not hesitate to inquiry now!