12v DC 4.5ah battery back-up UPS Power Supply (Braver LED/LCD)
USD $25 - $99 /Piece
Min.Order:10 Pieces
Shenzhen Helior Technology Co., Ltd.
12v DC 4.5ah battery back-up UPS Power Supply (Braver LED/LCD)
Outstanding Feature
1. Microprocessor control design guarantees high reliability;
2. Equipped with Boost and Buck AVR to Stabilize input voltage;
3. Built-in DC start function enables UPS to be started up without AC power supplied;
4. Auto restart while AC recovery;
5. Compact size, light weight;
6. Provides Modem/Phone line Surge Protection.(Option)
7. Provides Overload protection
Technical Specification
Model&Capacity
MODEL | Braver 400 LCD | Braver 600 LCD | Braver 800 LCD | |
CAPACITY | VA/W | 400VA/240W | 600VA/360W | 800VA/480W |
INPUT
Phase | Single | ||
Voltage | 110/120VAC or 220/230/240VAC | ||
Voltage Range | 81-145VAC / 162-290VAC +/- 5% | ||
Frequency | 50Hz / 60Hz ( Auto Sensing) | ||
Frequency Range | 45~55 Hz / 55~65Hz |
OUTPUT
Phase | Single | ||
Voltage(Btt. Mode) | 110/120VAC or 220/230/240VAC | ||
Voltage Regulation(Batt. Mode) | ±10% | ||
Frequency | 50Hz or 60Hz | ||
Frequency Regulation (Batt. Mode) | +/-1 Hz | ||
Output Waveform | Modified Sinewave |
Battery
Model | Braver 400 LCD | Braver 600 LCD | Braver 800 LCD |
Battery Type & Number | 12V/4.5AH x 1pcs | 12V/28W x 1pc | 12V/34W x 1pc |
Back up Time (at a PC load with 15"monitor) | 10 minutes | 20 minutes | 29 minutes |
Recharge Time | 8 hours to 90% after complete discharge |
Indicator
LCD Indicator with Blue Back Light | The LCD will self turn on when the UPS is functioning including in,off,charging mode and fault mode. |
Audible Alarm
Battery Mode | Sounding every 10 seconds | ||
Low Battery | Sounding every second | ||
Overload | Sounding every 0.5 second | ||
Fault | Continously sounding |
Customer Feedback
Our R&D team have tested your UPS, they are satisfied with the performance of the sample. All the test
results are complying with the specification. We are highly appreciated it. --- N. Raja (from Chennai, India)
We are quite impressive with the IGBT function of this UPS. We are now trying to apply this model on our
telecommunication systems. --- Robert Alles (from Munich, Germany)
Order information
Trade term: FOB Shenzhen / Hongkong
Delivery time: 7-21 days after confirmed the order
Packaging Detail:Standard export carton or OEM package
Warranty
1 years since the date of purchase
Warranty term
1. Under the terms of this warranty, if failure occurs under normal usage within warranty period, Helior Technology will provide free maintenance based on the proof-documents.
2. If Failure or damage occurs due to incorrect operation, wire connection, or any other mis-opeartions, Helior Technology will provide pay maintenance on charge basis.
More detailed info for family UPS & Inverter, please do not hesitate to inquiry now!