PT Value for solar water heater

PT Value for solar water heater

USD $7 - $20 /Set

Min.Order:100 Sets

Supply Ability:
2000 Set / Sets per Month
Port:
Shanghai/Ningbo
Payment Terms:
T/T

Quick Details View All >

Type:
Evacuated Tube
Pressure:
Pressurized
Certification:
CB
Place of Origin:
Zhejiang, China
Brand Name:
Sanneng/OEM
Model Number:
SN-PTV02

Haining Sanneng Solar Water Heater Co., Ltd.

Business Type: Manufacturer,Trading Company
Jiaxing Zhejiang China
Main Products: Solar water heater systemSolar water heater ,Solar collector ,Solar air conditioner ,Air conditioner assemblyNo more than 0.1 MPa ,100 degree centigrade

Product Details

solar water heater PT Value  

PT Value for solar water heater

T/P Valve

1, Use:

P/T Valve for solar water heater, electric heater and so on

2, T&P relief Valve Function:

The T&P valve is designed to relieve the increase in pressure which develops during the normal heating cycle.

This is caused by the water expanding during the heating cycle.The T/P valve then will relieve the increase in pressure by releasing drips of hot water to the drain line. It is recommended that an expansion control valve be fitted to the cold water supply line as it will relieve cold water(not hot water),during the heating cycle expansion,thereby saving energy and increasing the life of the T&P relief valve.Local regulations may make it mandatory to install an expansion control valve in the cold water supply line should the electrical temperature cut-out devices cease to operate correctly,the water will overheat and the temperature probe will then be activated to open the P/T valve,discharging hot water.

3, T/P relief valve for solar water heater

Inlet pressure control:

High pressure may cause excessive discharge and possible premature failure of the operating relief valve.The maximum water pressure usually occurs during the night, at the time of lowest water usage. In any mains pressure water heater installation,if the inlet water pressure exceeds 80% of the nominal set pressure of the operation relief valve,a pressure limiting valve must be fitted to the cold inlet.(If a cold water expansion control valve is fitted it will have a lower set pressure than the T/P relief valve and thus be classed as the "operating"relief valve.)

4,T&P Valve Installation:

T/P Valves should be installed by a licensed plumber.

If the temperature probe protruding from inside the inlet thread is damaged or bent,do not install,and obtain a replacement valve.

Clean out all deposits from the threaded boss on the heater before fitting a replacement valve,otherwise the new valve risks contamination and premature failure.Apply PTFE thread tape to the male taper thread,making sure that the tape does not hang over the outer end of the thread,as this can lead to premature valve failure.Screw the valve into the heater socket.Do not use a wrench on the valve body.Use teh hexagonal spanner flats provided.No valves,taps,or other isolating devices are to be fitted between the P&T relief valve and the water heater.

Install a drain line of the same nominal size as the valve,in accordance with AS3500.4.(The drain line must have a continuous fall.)

MODEL

SIZE

INSTALLATION

INLET

OUTLET

HOT WATER TAKE-OFF

PTV-15D

DN15

  COPING

R1/2"

Rc1/2"

----

PTV-20D

DN20

  COPING

R3/4"

Rc3/4"

----

Contact person: eva he

Tel: 0086-13511390503

Fax: 0086-0573-87869935

Skype: eva201423

Contact Supplier

Mr. junjie Wang General Manager, Cor Chat Now
Telephone
0086-573-87881860
Mobile
0086-13669284146
Fax
0086-573-87882198
Address
Long industrial park Zhejiang

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Home Appliances > Water Heaters > Solar Water Heaters
Categories
Hi~