Fuel (Oil)Turbine Digital Flow meter
USD $50 - $500 /Piece
Min.Order:10 Pieces
Xian Qin Wei Instrument Factory
digital Flow meter consists of two parts of the sensor and converter. It is based on Faraday's law of electromagnetic induction work, is used to measure the conductivity is greater than 5μS/cm conductive liquid volume flow rate, is a measure of a conductive medium volume flow sensing instrument. In addition to general conductive liquid volume flow can be measured, can also be used to measure the volumetric flow rate of the strong acid and alkali and other strong corrosive liquids and slurries, pulp, pulp homogeneous liquid-solid two-phase suspension liquid.
digital Flow meter Widely used in the industrial sector and the municipal administration of the petroleum, chemical, metallurgy, textile, papermaking, environmental protection, food, water conservancy construction, river dredging and other areas of flow measurement.
digital Flow meter
Technical parameters
Pife lined pipe | 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 | ||||
Rubber lined pipe | 40, 50, 65, 80, 100, 125, 150, 200, 300, 350, 400, 500, 600, 800, 1000, 1200, note: special specifications can be customized | ||||
Flow direction | positive and negative, net flows Turndown | ||||
Measuring range ratio | 150:1 | ||||
Repeatability error | +/-0.1% | ||||
Accuracy | piped: 0.5 class, 1.0 class | ||||
Measured medium temperature |
| ||||
Rated working pressure | pipeline: DN10~DN65: ≤ 2.5MPa;DN80~DN150: ≤ 1.6MPa; DN200~DN1200: ≤ 1.0MPa | ||||
Flow measuring range | flow measuring range corresponding to flow rate range is 0.3~15m/s | ||||
Measured fluid conductivity | 5μs/cm (Most with water as the composition of the medium, its conductivity in the range 200~800 Mu s/cm, optional solenoid flow) | ||||
Output | current :4~20mADC (isolation), pulse frequency 0~1kHz, OCT photoelectric isolation, external power ≤ 35VDC, breakover, collector Max 25mA | ||||
Load resistance | < 600 Ω | ||||
Electrode material | 316L, titanium (Ti), tantalum (Ta), Hastelloy, (h), Platinum (Pt) or other special electrode materials | ||||
Protection grade | standard: IP65; IP68 | ||||
Working power supply | 85~265VAC 45~63HZ | ||||
Straight pipe length | pipe: ≥ 5DN in the upper reaches, downstream of greater than or equal to 2DN | ||||
Connections | flow meter connected to the piping is used between flanges, flange connection dimensions comply with GB9119-88 requirements. | ||||
Explosion-proof mark | mdllBT4 | ||||
environment temperature | -25 ° c ~=60 ° c | ||||
Relative humidity | 5%~95% | ||||
Total power consumption | <20W |