Rubber Insulated and Jacketed Cable Wire
USD $0.3 - $45.3 /Meter
Min.Order:500 Meters
Hengyang Hengfei Cable Co., Ltd.
4. ISO,SGS..Certificate
5. IEC Standard
6.Response within 12 hours
Rubber Insulated and Jacketed Cable Wire
Application:
This product is appli cable to the AC rated voltage 0.6/1kV and below requires frequent or oil-resistant occasion for power plant or moving lighting electricity power transmission. Product has good flexibility,ageing resistance properties.
Voltage: 450/750V and below.
Standard: IEC60332:1993
Using Features :
Silicon rubber insulation and flat cable
The working temperature of cable conductor is equivalent to insulation materials;
The minimum bending radius of cable:non-shield type cale is 6D;shield type is 8D
Silicon rubber insulation and flat cable
The long-term allowable working temperatute of cable conductor should be not more than 70oC;
The environment temperature for laying cable is below 0oC ,ordinary type cable, the bending radius is not less than 6 times of the thickness of cable, shield-type,the bending radius is not less than 10 times of the thickness of calbe
Reted Voltage 0.6/1kV Silicon Rubber Insuation Flat Cable
When laying the cable, ordinary type bending radius is not less than 6 times of the thickness of cable,shield-type bending radius is not less than 10 times of thickness of cable;
The environment temperature of the cable is -60~+180oC;
Welding Cable
The highest working temperature of cable conductor is 65oC
The minimum bending radius of cable is 4 times of the diameter.
Motor Winding Lead Flexible Cable
The minimum bending radius of cable should be not less than 6 times of cable diameter.
Compound Special Rubber Flexible Cable
The highest working temperature of the cable conductor should be not more than 80oC
The working environmental temperature of cable should be not lower than-40oC
Radio Installation Cable
The long term working temperature is 65oC;
The bending radius for the laying cable should be not less than 10 times of its diameter.
Light-type rubber sheath flexible cable
The long term working temperature of cable should be not more than 65oC;
W-type derived cable has climate-resistant and certain oil-resistant properties , so it is suitable for outdoors or occasions with oily;
The minimum bending radius of cable should be not less than 6D(D is the diameter)
Product description:
Silicon rubber insulation and flat cable
Type | Descripton | Application Temperature |
YVFR | PVC insulation NBR compound sheath flexible power cable | -25~70oC |
YVFRP | PVC insulation NBR compound sheath braided shield flexible power cable | -25~70oC |
YFFR | NBR compound insulation NBR compound sheath flexible power cable | -25~70oC |
YFFRP | NBR compound insulation NBR compound sheath braided shield flexible power cable | -25~70oC |
YGG | Silicom rubber insulation silicon rubber sheath flexible power cable | -60~180oC |
YGGP | Silicom rubber insulation silicon rubber sheath braided shield flexible power cable | -60~180oC |
YGC | Silicom rubber insulation heavy rubber sheath flexible power cable | -35~65oC |
YGCP | Silicom rubber insulation heavy rubber sheath braided shield flexible power cable | -35~65oC |
KGG
Silicon rubber insulation and flat cable :
Type | Description |
YVFB | Copper core PVC insulation acrylonitrile-butadiene PVC compound sheath flat cable |
YVFBP | Copper core PVC insulation braided shield acrylonitrile-butadiene PVC compound sheath flat cable |
YFFB | Copper core acrylonitrile-butadiene PVC compound insulation acrylonitrile-butadiene PVC compound sheath flat cable |
YFFBP | Copper core acrylonitrile-butadiene PVC compound insulation braided shield acrylonitrile-butadiene PVC compound sheath flat cable |
Reted Voltage 0.6/1kV Silicon Rubber Insuation Flat Cable
Type | Description | Application Temperature |
YGGB | Copper core silicon rubber insulation silicon rubber sheath flat cable | -60~180oC |
YGGBP | Copper core silicon rubber insulation braided shield silicon rubber sheath flat cable | -60~180oC |
YGCB | Copper core silicon rubber insulation heavy duty rubber sheath flat cable | -40~65oC |
YGCBP | Copper core silicon rubber insulation braided shield heavy duty rubber sheath flat cable | -40~65oC |
YGFB | Copper core silicon rubber insulation acrylonitrile-butadiene PVC compound sheath flat cable | -20~70oC |
YGFBP | Copper core silicon rubber insulation braided shield acrylonitrile-butadiene PVC compound sheath flat cable | -20~70oC |
Copper core silicon rubber insulation silicon rubber sheath control flexible cable
Type | Desscription |
KGG | Copper core silicon rubber insulation silicon rubber sheath control flexible cable Copper core silicon rubber insulation silicon rubber sheath control flexible cable |
KGGP | Copper core silicon rubber insulation silicon rubber sheath braided shield control flexible cable |
Welding Cable
Type | Desscription |
60245IEC81(YH) | Rubber sheath welding cable |
YH | Welding cable |
Type | Desscription |
FTYKR | Compound special rubber flexible cable |
Cable Structure Schene:
Product picture:
Product Test &