Temperature And Humidity Walk in Environmental Chamber
USD $9,000 - $15,000 /Unit
Min.Order:1 Unit
Xi'an LIB Environmental Simulation Industry Electronics Technology Co., Ltd.
Walk in Environmental Chamber
Walk in Environmental Chamber Application
Walk in Environmental Chamber is widely used in the temperature variation tests, cold resistance tests and storage with low-temperature in the fields of aerospace, aviation, electronics, instrument, electric products, materials, parts and components and equipment to analyze and evaluate the property and performance of the samples under the simulated conditions.
Walk in Environmental Chamber design drawing
Walk in Environmental Chamber Controller
TEMI880 touch-screen type temperature and humidity programmable controller
Setting mode: touching type
Program: 100 groups in 1000 sections
Resolution: temperature: ± 0.1 ℃; humidity: ± 1%RH
Communication function: LAN network interface
Walk in Environmental Chamber Compressor
TECUMSEH from France
Single compressor for the -20°C
Double compressors for the -40°C~-70°C
Temperature test system
Product name | Type | Workroom Dimension (mm) | Volume (m3) | Temperature range ( ℃ ) | standard | |
Temperature Test Room | HTT1003F | 1500×1200×1500 | 3 | R.T.+10~+100℃ | GB11158-89 GB2423.2-89 GB2423.2-89 | |
HTT1005F | 2000×1200×2000 | 5 | ||||
HTT1008F | 2000×2000×2000 | 8 | ||||
HTT1010F | 2500×2000×2000 | 10 | ||||
HTT1015F | 3800×2000×2000 | 15 | ||||
HTT1020F | 4000×2500×2000 | 20 | ||||
HTT1025F | 4000×2500×2500 | 25 | ||||
HTT1030F | 4000×3000×2500 | 30 | ||||
HTT1050F | 5000×4000×2500 | 50 | ||||
HTT1080F | 8000×4000×2500 | 80 | ||||
HTT1100F | 10000×4000×2500 | 100 |
Product name | Type | workroom Dimension (mm) | Volume (m3) | Temperature range ( ℃ ) | Note | standard | |
HRT6003F | 1500×1200×1500 | 3 | HRTR-F Series R.T.+10~+85, HRT0-F Series :-5~+85, HRT2-F Series: -20~+85, HRT4-F Series : -40~+85, | HRTR-F Series Humidity range: 60~95%R.H, Other humidity range:30~95%R.H. | GB10586, | ||
Temperature & humidity test chamber test room | HRT6005F | 2000×1200×2000 | 5 | ||||
HRT4008F | 2000×2000×2000 | 8 | |||||
HRT4010F | 2500×2000×2000 | 10 | |||||
HRT2015F | 3800×2000×2000 | 15 | |||||
HRT2020F | 4000×2000×2500 | 20 | |||||
HRT0030F | 4000×3000×2500 | 30 | |||||
HRT0050F | 5000×4000×2500 | 50 | |||||
HRTR080F | 8000×4000×2500 | 80 | |||||
HRTR100F | 10000×4000×2500 | 100 |
Temperature & humidity walk in room
Product name | Type | workroom Dimension (mm) | Volume (m3) | Temperature range ( ℃ ) | standard | |
High-low temperature test room | HLT0003F | 1500×1200×1500 | 3 | HLT0-F Series -5~+85, HLT2-F Series -20~+85, HLT4-F Series -40~+85, HLT6-F Series -65~+85 | ||
HLT0005F | 2000×1200×2000 | 5 | GB10592-89 | |||
HLT0008F | 2000×2000×2000 | 8 | GB2423.1-89-A | |||
HLT2010F | 2500×2000×2000 | 10 | HEC68-2-1-A | |||
HLT2015F | 3800×2000×2000 | 15 | GB2423.22-89-Nb | |||
HLT2020F | 4000×2000×2500 | 20 | GJB150.3-86 |
Walk in Environmental Chamber Pictures
Walk in Environmental Chamber Package
LIB Industry Waranty
LIB Industry Manufactory
LIB Industry Certification