Low-Smoke Halogen-Free Flame Retardant XLPE Insulation Power Cable
USD $0.3 - $35.6 /Meter
Min.Order:500 Meters
Hengyang Hengfei Cable Co., Ltd.
Low-Smoke Halogen-Free Flame Retardant XLPE Insulation Power Cable
Advantages
1. IEC, ASTM, DIN, BS standard
2. ISO9002,ISO14000:2004 ,CCC,CB ,ROHS,MA,CRCC,TUV, certification
3.Professional QC inspection
4.Purity raw material,99.99% T2
5.Response within 12 hours
6.Free Sample
Applications:
Low-smoke Halogen-free flame retardant Wire and Cable can produce little smoke and innocuous gas without halogen when combustion.
It can extremely reduce the damage to the instruments and body as the fire occurred .So, it was widely used in high-rise building, hospital,
large-sized library, gymnasium, disaster prevention command and dispatchbuilding, station, civil airfield, passenger waiting room,emphases
cultural relic, subway, underground shop or the crowded public concourses.
Standards:
IEC6052:2004 IEC60050:1984 IEC60227:1997 IEC60332:2000
Using Features:
The highest working temperature of cable conductor:XLPE insulation is 90oC;irradiation cross-linked polyolefin insulation is 105oC 125oC; | |
The environment temperature for laying cable should be not less than0oC | |
For Low-smoke Halogen-free Cable:the PH of the cable's combustion gas should be 4.3 or higher; the conductivity is 10us/mm or lower, the lowest light transmittance of the fished cable should be not less than 60% while burning. |
Product Description:
Type | Description | Flame retardant grade |
WDZ-YJY | Copper core XLPE insulation low-smoke halogen-free polyolefin sheath flame retardant power cable | A/B/C |
WDZ-YJY23 | Copper core XLPE insulation steel tape armoured low-smoke halogen-free polyolefin sheath flame retardant power cable | |
WDZ-YJY33 | Copper core XLPE insulation thin steel wire armoured low-smoke halogen-free polyolefin sheath flame retardant power cable | |
WDZ-YJY43 | Copper core XLPE insulation thick steel wire armoured low-smoke halogen-free polyolefin sheath flame retardant power cable | |
WDZ-YJ(F)Y | Copper core low-smoke halogen-free irradiation cross-linked polyolefin insulation low-smoke halogen-free polyolefin sheath flame retardant power cable | |
WDZ-YJ(F)Y23 | Copper core low-smoke halogen-free irradiation cross-linked polyolefin insulation steel tape armoured low-smoke halogen-free polyolefin sheath flame retardant power cable | |
WDZ-YJ(F)Y33 | Copper core low-smoke halogen-free irradiation cross-linked polyolefin insulation steel wire armoured low-smoke halogen-free polyolefin sheath flame retardant power cable | |
WDZ-YJ(F)Y43 | Copper core low-smoke halogen-free irradiation cross-linked polyolefin insulation thick steel wire armoured low-smoke halogen-free polyolefin sheath flame retardant power cable | |
WDZN-YJY | Copper core XLPE insulation low-smoke halogen-free polyolefin sheath flame retardant fire rsistance power cable | |
WDZN-YJY23 | Copper core XLPE insulation steel tape armoured low-smoke halogen-free polyolefin sheath flame retardant fire rsistance power cable | |
WDZN-YJY33 | Copper core XLPE insulation thin steel wire armoured low-smoke halogen-free polyolefin sheath flame retardant fire rsistance power cable | |
WDZN-YJY43 | Copper core XLPE insulation thick steel wire armoured low-smoke halogen-free polyolefin sheath flame retardant fire rsistance power cable | |
WDZN-YJ(F)Y | Copper core low-smoke halogen-free irradiation cross-linked polyolefin insulation low-smoke halogen-free polyolefin sheath flame retardant fire resistance power cable | |
WDZN-YJ(F)Y23 | Copper core low-smoke halogen-free irradiation cross-linked polyolefin insulation steel tape armoured low-smoke halogen-free polyolefin sheath flame retardant fire resistance power cable | |
WDZN-YJ(F)Y33 | Copper core low-smoke halogen-free irradiation cross-linked polyolefin insulation thin steel wire armoured low-smoke halogen-free polyolefin sheath flame retardant fire resistance power cable | |
WDZN-YJ(F)Y43 | Copper core low-smoke halogen-free irradiation cross-linked polyolefin insulation thick steel wire armoured low-smoke halogen-free polyolefin sheath flame retardant fire resistance power cable | |
WDZ-KYJY | Copper core XLPE insulation polyolefin sheath low-smoke halogen-free flame retardant control cable | |
WDZ-KYJYP | Copper core XLPE insulation polyolefin sheath braided shield low-smoke halogen-free flame retardant control cable | |
WDZ-KYJYP2 | Copper core XLPE insulation polyolefin sheath copper tape shield low-smoke halogen-free flame retardant control cable | |
WDZ-KYJYP3 | Copper core XLPE insulation polyolefin sheath Al-plastic composite tape shield low-smoke halogen-free flame retardant control cable | |
WDZ-KYJY23 | Copper core XLPE insulation polyolefin sheath steel tape armoured low-smoke halogen-free flame retardant control cable | |
WDZ-KYJYP2-23 | Copper core XLPE insulation polyolefin sheath copper tape shield steel tape armoured low-smoke halogen-free flame retardant control cable |
About us