Light and Portable Multipara Monitor with Build-in Rechargeable Battery
Negotiable /Unit
Min.Order:1 Unit
We offer cms 8000 model are known for their wide functionalities. These are used to report respiration, SPO2, ECG, Temperature, RESP,monitor, essential measurement parameters such as SpO2, TEMP, ECG, PR/HR, RESP and NIBP. These monitors are designed by latest digital technology which gives excellent accuracy.
We have with us CMS 8000 Multipara Monitors that are designed using latest technology and as per the international standards. Procured from our reliable vendors, these monitors are compact in size and are easily portable. These monitors are incorporated with adjustable audible and visual alarm and other safety features. Further, our monitors are available in different specifications and at industry leading prices.
Features: -
Some features of the products are as follows :
Color TFT Screen, waveform up to 8 channels
Light and portable with build-in rechargeable battery
UP to 10 kinds of monitor parameters
Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
72 hour storage and review of trend grams and tables, 40 second review of olographic wavefo RMS.
Built-in recorder(option)
All-round monitor of adult, pediatric and neonatal.
Electrosurgical unit and defibrillation protected
Standard parameters: ECG, NIBP, SpO2, Respiration, Temperature, Pulse rate
Option parameters: EtCO2, CO, IBP, Thermal Printer
ECG
5-lead or 3-lead selectable
Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
Lead selection: I; II; III; AvR; AvL; AvF; Vx; CAL
Gain selection: 12.5mm/s, 25mm/s, 50mm/s
Accuracy: ± 1bpm or ± 1%, whichever is greater
Protection: Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
Calibration signal: 1mV± 5%
Operation modes: Diagnostic, Monitor, Surgery
Alarm range: Adult: 15-300bpm
Pediatric/Neonatal: 15-350bpm
Alarm range: -2.0mV~2.0mV
S-T detection: YES, Arrhythmia analysis: YES
Alarm: YES, audible and visual alarm, alarm events recallable
NIBP
Method: Oscillometry
Operation modes: Manual/Automatic/STAT
Measurement unit: MmHg/KPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10-270mmHg
Over-pressure protection: YES
Resolution: 1mmHg
Accuracy: Mean error and standard deviation per ANSI/AAMI SP-10
Alarm: Systolic, Diastolic, Mean
SpO2
Measurement range: 0-100%
Accuracy: ± 2digit (70~100%);
0~69% unspecified
Alarm range: 0-100%
Respiration
Method: RA-LL impedance
Pediatric/Neonatal: 6-150rpm
Alarm range: Adult: 6-120rpm
Pediatric/Neonatal: 6-150rpm
Apnea alarm: YES
Temperature
Resolution: 0.1
Channel: Dual-channel
Alarm range: 0-50
Option
EtCO2
Measurement Mode: Side-stream or mainstream
Measurement range: EtCO2: 0-99mmHg
Accuracy: CO2 concentration
Apnea alarm: YES
CO
Method: Thermo-dilution
Measurement range: CO: 0.1-20 lit. /min.
IBP
Channel: 2 channels
Pressure transducer: Sensitivity: 5( mV/V/mmHg)
Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Alarm range: -10~300mmHg