Christmas Warm House Floor Heating Wire Cable System
USD $1 - $3 /Meter
Min.Order:1 Meter
Hefei Minco Heating Cable Co., Ltd.
Christmas Warm House Floor Heating Wire Cable System
Description
Minco heating cable is highly efficient, energy-saving, concealed low-temperature radiant soil warmming system. It is charcterized by green and environment-friendliness, energy conservation, low cost of installation and maintenance,etc. It can be used for roof/gutter/walkway snow melting .Minco it's the best choice for you !
Structure
Heating wire:copper alloy wire
Series structure without voltage drop;the temperature of whole cable is even.
Insulation material:cross linked polyethylene(XLPE)
The long-term working temperature is 105°C,The instantaneous overload temperature is 205°C .
Ground wire:Tin plated copper
8 tin plated copper wires with a diameter of 0.4mm
Shieldinglayer:Luminum foil
Thickened Aluminum composite membrane shielding layer can shield the
electromagnetic radiation effectively which already passed the American
electromagnetic radiation detection and the European U nion CE certification.
Jacket:PVC
Antiseptic,waterproof and anti-aging
Details
Brand Name:Minco
Heating Cable Type:Single/Twin conductor cable
Model:TXLP/1,TXLP/2R
Linear Power:18.5W/M
Voltage:220V
Lifespan:50 years
Warranty:10 years
Certification:CE,GOST,ROHS,FIRE RESISTANT
Specification
TXLP/1 series single conductor Electric Heating Cable(220V 18.5W/M) | |||||
Power(W) | Cable model | Voltage(V) | Standard length(M) | Power per meter(W/M) | Total value of resistance(Ω) |
3150 | TXLP/2R/18.5 | 220 | 170.3 | 18.5 | 15.4 |
2800 | TXLP/2R/18.5 | 220 | 151.4 | 18.5 | 17.3 |
2600 | TXLP/2R/18.5 | 220 | 140.5 | 18.5 | 18.6 |
2400 | TXLP/2R/18.5 | 220 | 129.7 | 18.5 | 20.2 |
2200 | TXLP/2R/18.5 | 220 | 118.9 | 18.5 | 22.0 |
2000 | TXLP/2R/18.5 | 220 | 108.1 | 18.5 | 24.2 |
1760 | TXLP/2R/18.5 | 220 | 95.1 | 18.5 | 27.5 |
1600 | TXLP/2R/18.5 | 220 | 86.5 | 18.5 | 30.3 |
1400 | TXLP/2R/18.5 | 220 | 75.7 | 18.5 | 34.6 |
1200 | TXLP/2R/18.5 | 220 | 64.9 | 18.5 | 40.3 |
1000 | TXLP/2R/18.5 | 220 | 54.1 | 18.5 | 48.4 |
850 | TXLP/2R/18.5 | 220 | 45.9 | 18.5 | 56.9 |
700 | TXLP/2R/18.5 | 220 | 37.8 | 18.5 | 69.1 |
600 | TXLP/2R/18.5 | 220 | 32.4 | 18.5 | 80.7 |
500 | TXLP/2R/18.5 | 220 | 27.0 | 18.5 | 96.8 |
400 | TXLP/2R/18.5 | 220 | 21.6 | 18.5 | 121.0 |
300 | TXLP/2R/18.5 | 220 | 16.2 | 18.5 | 161.3
|
TXLP/2R series twin conductor Electric Heating Cable(220V 18.5W/M) | |||||
Power(W) | Cable model | Voltage(V) | Standard length(M) | Power per meter(W/M) | Total value of resistance(Ω) |
3150 | TXLP/2R/18.5 | 220 | 170.3 | 18.5 | 15.4 |
2800 | TXLP/2R/18.5 | 220 | 151.4 | 18.5 | 17.3 |
2600 | TXLP/2R/18.5 | 220 | 140.5 | 18.5 | 18.6 |
2400 | TXLP/2R/18.5 | 220 | 129.7 | 18.5 | 20.2 |
2200 | TXLP/2R/18.5 | 220 | 118.9 | 18.5 | 22.0 |
2000 | TXLP/2R/18.5 | 220 | 108.1 | 18.5 | 24.2 |
1800 | TXLP/2R/18.5 | 220 | 97 | 18.5 | 26.9 |
1600 | TXLP/2R/18.5 | 220 | 86 | 18.5 | 30.2 |
1370 | TXLP/2R/18.5 | 220 | 74.1 | 18.5 | 35.3 |
1250 | TXLP/2R/18.5 | 220 | 67.6 | 18.5 | 38.7 |
1000 | TXLP/2R/18.5 | 220 | 54.1 | 18.5 | 48.4 |
840 | TXLP/2R/18.5 | 220 | 45.4 | 18.5 | 57.6 |
700 | TXLP/2R/18.5 | 220 | 37.8 | 18.5 | 69.1 |
600 | TXLP/2R/18.5 | 220 | 32.4 | 18.5 | 80.7 |
500 | TXLP/2R/18.5 | 220 | 27.0 | 18.5 | 96.8 |
400 | TXLP/2R/18.5 | 220 | 21.6 | 18.5 | 121.0 |
300 | TXLP/2R/18.5 | 220 | 16.2 | 18.5 | 161.3 |
Application
Advantges
Safe: High efficient and convenient heating system.
Automatism: Heating system can automatically (by thermostat)measure the heating requirement, and timely adjust the heating temperature.
Economical: The cost of installation and operation is relatively low; our heating system can efficiently avoid damage and save maintain fees.
Environmental: Our heating system use the cleanest power which are popular between customers.
Spanlife:Almost 50m years.
Certifiction:CE,ROHS GOST,FIRE RESISTANT
Warranty:10 years
Installation
Tips
1). Heating cable fix materials: Aluminum tape.
2). Cross tube materials: Use steel or PVC tube.
3). Don't damage cable. The bend radius should be more than 6 times of thickness of cable.
4). Heat insulation materials should be dry and the joint of cable should be sealed.
5). The junction box should be sealed.
6). Protective sleeve must not be damaged during installation, and the core wire can not bare.
7). The heating cable should be installed accurately according to the design graphics.
Delivery deatails
We will prepare shipping asap once we receive your money, nd give you the tracking number after we send out your goods. Usually within 5-35 working days you can receive your item. Please wait patiently!
Certifictions
Methods of Payment:
Payment methods | Commission fee | Arriving days afer paying |
| No commission fee | 3-5 working days |
| 3.9%+0.3 usd |
Instant |
| No commission fee |
Instant |
| No commission fee |
Instant |
|
Alibaba calculate it |
Instant |
Welcome! My friend! We are glad to customize your products according to your requests! We can give you a discount accroding to the quantity if you buy a largequantity. Welcome your request for quotation!
More similar products please visit: http://mkheatingcable.en.china.cn/