25KW high frequency induction heating for bolts/nuts DD25JQ
USD $500 - $10,000 /Set
Min.Order:1 Set
Shenzhen Dongda Industrial Co., Ltd.
Induction Power
High frequency induction brazing machine DD25JQ
Model | DD-25 II |
Max osc. power | 25KVA |
Input volt. | Three phase 380V-50-60HZ |
Input volt. range | 340V-420V |
Output osc. frequency | 30-80KHZ |
Heating current | 200A-1000A |
Load duration rate | 90% |
Requirement for cooling water | Water pressure ≥0.2Mpa Flow: 2~5L/min. |
Heating, heat keeping current | 200-1000A |
Heating, Cooling Time | 1-99 sec |
Heat keeping time | 1-99 sec |
1. low energy consumption
2. high production efficiency
3. easy operation
3. environment friendly
Main parameters
1. It adopts the latest MOSFET and IGBT frequency conversion control technology. It has Advantages of high efficiency, energy saving and high output power;
2. It has constant current and constant power control function, which significantly optimize metal heating process, so that makes it possible for fast speed heating and brings the superiority of product into full play;
3. It has time setting function of heating, heating preservation and cooling. Moreover, the power of heating and heating preservation could be adjusted respectively. It is applicable for batch and repeated heating places;
4. It has as many as ten types of fault protection and display function including over-current, over-voltage, phase missing, which provides reliability and durability;
5. It is safe and reliable, and do not have ten thousand voltage, thus ensure safe operation;
6. It has full load design, which makes it possible for 24-hour continuous operation. Infrared temperature measurement is available for automatic control of temperature. This improves heating quality and simply manual operation.
Model | DD-25 JQ |
Max osc. power | 28KVA |
Input volt. | Three phase 380V-50-60HZ |
Input volt. range | 340V-420V |
Output osc. frequency | 30-100KHZ |
Heating current | 10A-40A |
Load duration rate | 100% |
Requirement for cooling water | Water pressure ≥0.2Mpa Flow: 6L/min. |
Heating, heat keeping current | 20-40A |
Heating, Cooling Time | 1-99 sec |
Heat keeping time | 1-99 sec |
Installation & Maintenance Guide for Dongda Induction Heating Equipment
Installation & Maintenance of Cooling System
I. Purpose of the cooling water:
II. Requirements to cooling water:
1. Water temperature at the inlet: <40°C;
2. Pressure: >0.2Mpa;
3. Flow: 5-10L/min, the max water temperature at the outlet should be no more than 70°C;
4. Water quality: purified and demineralized.
...