medical anaesthesia mnachine/making machine medical
USD $1,800 - $3,500 /Set
Min.Order:500 Sets
Ningbo Safebond International Trade Co., Ltd.
medical anaesthesia mnachine/making machine medical
high-grade type
High- precision evaporator, either Halothane, Enflurane, Isoflurane or Sevoflurane configuration.
Double-tubes O2 flowmeter, standard loop system,
ABS Engineered plastic frame, children or adult bellows, screen display ventilator (IPPV, MANUAL,
ventilation volume, tidal volume, respiratory rate) ,
real-time display of respiratory duct pressure, clear at one glance). Enflurane anesthesia or other
gas anesthesia machine
Main body | High-strength engineering plastic rack, light, beautiful and corrosion resistant |
Scope of application | adult, child |
Gas source | O2: 0.27~0.55MPa |
Flow meter | O2: 0.1~2L/min 2.5~10L/min |
Flow rate of rapid oxygen supply | 25~75L/min |
Low oxygen pressure alarm(Oxygen Alarm) | There will be sound alarm when the oxygen pressure < 0.2MPa |
Vaporizer | It has the function of automatic compensation based on pressure,temperature,and flow rate.The regulation range of evaporator concentration is 0~5 vol%.Among Halothane,Enflurane,Isoflurane and Sevoflurane,one can be chosen for application as required by the customer. |
Respiratory circuit | working mode: all-close, semi-close, semi-open releasing pressure: 0.5~7 kPa |
Respiratory bellows | bellows for adults, bellows for children tidal volume range:0~1500 ml |
Ventilator (Ventilator Definition and Ventilator Function) | |
Display mode | digital screen display |
Ventilation mode | IPPV, MANUAL (Manual monitoring of tidal volume, ventilation volume, respiratory rate) |
Ventilation parameters | Tidal volume 50~1500ml Rate 2~99 bpm SIMV rate 2~20 bpm I:E 2:1~1:8 Inspiratory trigger pressure -1.0~2.0 kPa Pressure range 1.0~6.0 kPa |
Parameters for ventilation monitoring | tidal volume, ventilation volume, IPPV rate, I/E, peak pressure of airway, inspiratory trigger pressure, pressure - time waveform |
Security Alarm System | |
Airway pressure alarm | upper limit setting range 1.0~6.0 kPa low limit setting range 0.4~2.0 kPa |
Per-minute ventilation volume alarm | upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min |
Sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 2.5 kPa |
Suffocation alarm | it will give sound and light alarm if there is no tidal volume input in 15s |
Power alarm Power |
AC 220V±10% 50Hz±1Hz |
Lf you have any question,please contact us.