ASTM D2500 Petroleum products pour point cold filter plugging point tester instrument
USD $100 - $30,000 /Set
Min.Order:1 Set
Changsha Friend Experimental Analysis Instrument Co., Ltd.
Petroleum products pour point& cold filter &plugging point tester FDT-0311
Application range
Conforms to standard GB/T510 &SH/T0248”” cold filter plugging point of distillate fuels Determination “” .High precision temperature control, temperature uniformity andstability of The cold bath, suitable for oil exploration, production, anduse of The unit, The relevant institutions, research departments for The determination of The freezing point of petroleum products.
Features
1 imported brandcompressor, The unique metal cold bath, no alcohol andother media, The cooling speed, The cooling effect is good.
2, equipped with a filtration device, The pour point and the cold filter plugging point test can be conducted.
3, digital temperature control technology, precision temperature sensor, accurate temperature control.
4, with automatic timing, when The alarm function.
Specifications
1 Power supply: AC 220V ± 10%; 50Hz.
2 cold trough: single slot two-bath, two-bath temperature.
Single two -bath , two-bath new refrigeration compressor isothermal temperature ~ -35
Petroleum products pour point& cold filter &plugging point tester FDT-0311
Application range
Conforms to standard GB/T510 &SH/T0248”” cold filter plugging point of distillate fuels Determination “” .High precision temperature control, temperature uniformity andstability of The cold bath, suitable for oil exploration, production, anduse of The unit, The relevant institutions, research departments for The determination of The freezing point of petroleum products.
Features
1 imported brandcompressor, The unique metal cold bath, no alcohol andother media, The cooling speed, The cooling effect is good.
2, equipped with a filtration device, The pour point and the cold filter plugging point test can be conducted.
3, digital temperature control technology, precision temperature sensor, accurate temperature control.
4, with automatic timing, when The alarm function.
Specifications
1 Power supply: AC 220V ± 10%; 50Hz.
2 cold trough: single slot two-bath, two-bath temperature.
3, The cold tank temperature control: room temperature ~~ -70 ° C. (It can be customized according to user needs)
4, temperature accuracy: ± 0.5° C
5, The refrigeration system: imported refrigeration compressor.
Ambient temperature: 30° C
7, Relative humidity: 85%.
8 Total power consumption: not more than 700W.
3, The cold tank temperature control: room temperature ~~ -70 ° C. (It can be customized according to user needs)
4, temperature accuracy: ± 0.5° C
5, The refrigeration system: imported refrigeration compressor.
Ambient temperature: 30° C
7, Relative humidity: 85%.
8 Total power consumption: not more than 700W.
Packaging Details: Standard export packing
Delivery Detail: within 10 days
1,warranty period, scope, and warranty conditions
" one year warranty, Product maintenance, software upgrades, installation, Training operators "
2,Speed problem solving
Get a phone call within 2 hours to give back
3,Devices with training, mentoring
Training schedule
NO |
Training Content |
Days | place |
Note | |||
Title | Number | ||||||
1 |
Training of the operating system | 2 | engineer | 1 | scene
|
| |
2 |
Instrument training : system use, test procedures, production of the report
| 2 | engineer | 1 | scene
|
| |
3 |
Introduces the details of the principle and design of software system, system hardware components, external device interface, System maintenance and general Fault Diagnosis and repair
| 2 | engineer | 1 | scene
|
| |
4 | Environmental equipment room requirements and maintenance, basic knowledge of computer hardware, instrument internal structure and external interface of the host, computer hardware and system software maintenance and general troubleshooting
| 2 | engineer | 1 | scene
|
| |
Other after-sales service commitment (installation, regular inspection etc. )
During use of the product to send personnel to visit from time to time, to understand the use of equipment, and stored in user profiles
5,
Service Contacts
Contact: Jiang Haihua
Tel :13974982773
other preferential terms
Each year held user classes in Changsha by experienced technical engineers. To provide users detailed training instrument works, methods of operation and routine maintenance and repairs.
Provide instruments easily worn parts