Amisy Portable SO2(Sulfur dioxide) gas analyzer 008615037127860
Negotiable /Set
Min.Order:1 Set
Zhengzhou Amisy Trading Co., Ltd.
Amisy! NZ-03 Fixed H2 gas monitor/Hydrogen gas monitor website:nicolezhang30
Amisy! NZ-03 Fixed H2 gas alarm/Hydrogen gas alarm website:nicolezhang30
Amisy! NZ-03 industrial Fixed H2 gas leak detector website:nicolezhang30
Amisy! NZ-03 Fixed H2 gas leak detector Hydrogen leak detector website:nicolezhang30
Amisy! NZ-03 Fixed H2 detector Hydrogen gas detector website:nicolezhang30
Amisy! NZ-03 Fixed H2 gas detector Hydrogen gas detector website:nicolezhang30
Amisy Portable SO2(Sulfur dioxide) analyzer
Brief Introduction:
Amisy portable SO2(Sulfur dioxide) gas detector is a inspection tool to inspect the combustible gas concentration and toxic gas concentration in industrial environment
continuously. The instrument is used to detect the gas concentration in the way of
natural diffusion.It adopts the imported electrochemical sensor and has excellent
sensitivity and remarkable repeatability.
Applications:
It is widely used in underground pipeline, mine, petroleum and other spots where
need to prevent fire, explosion and toxic gas from leakage. What's more important is
that it can protect personal safety and equipment safety effectiovely.
SO2(Sulfur dioxide) gas alarm/leak detector
Main functions and features:
Large screen LCD:
English display
Shows the measured gas concentration and real time
Fault under voltage indication
Design:
Ergonomic design,comfortable feel,easy to use
Impact composite materials,Anti - radio interference(RFI)
Small figure, light weight and easy to carry
Large capacity battery:
1900mAh capacity, which can provide the long time for you to use
It is connivent to charge with USB interface
Under voltage tips
Easy maintenance:
It's convenient to maintain and replace with modularized sensor
It has automatic calibration which can reduce the detected error when you open it
It has advanced a self-diagnosis and self-healing capabilities
Main technical parameters:
Measuring gas | SO2(Sulfur dioxide) |
Masuring range | 0-20pm |
Sensor Principle | Electrochemical principle |
Resolution | 0.1ppm |
Accuracy | ±3%F.S |
Response time | ≤30 s |
Temperature | -20 - +50°C |
Humidity | 15% - 95% RH (non-condensing) |
Alarm point | First stage:5ppm,second-stage: 10ppm Users can set the alarm point by theirselves to meet their needs |
Alarm Indication | Alarm with brilliant light, vibration and high-frequency buzz |
Running time | combustible gas < 8h,toxic gas < 80h |
Dimension | 110mm(L)x 65mm(W)x 35mm(H) |
Instrument Net Weight | 163g |
Gross Weight | 0.487Kg |
Explosive-proof Degree | Exia Ⅱ CT3 |
Protection Grade | IP65 |
Gas selection sheet: