Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)

Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)

USD $200 - $10,000 /Unit

Min.Order:5 Units

Supply Ability:
5000 Unit / Units per Month
Port:
Guangzhou China
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Type:
Air Source Heat Pump
Installation:
Freestanding
Storage / Tankless:
Instant / Tankless
Housing Material:
Other, Stainless Steel/Powder Coated Steel
Use:
Other, Houses, Villas
Certification:
CB, CE, EMC, EMF, Other, SASO, UL, CB, CE, EMC, EMF, RoHS, SASO, UL, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, SABS, SANS, SAA, VDE

Guangdong PHNIX Eco-Energy Solution Ltd.

Business Type: Manufacturer,Trading Company
Guangzhou Guangdong China
Main Products: Swimming Pool Heat Pump ,Room Heating Heat Pump ,Fan CoilOnly Sales ,Spare Parts Of Heat PumpOnly Sales

Product Details

Geyser Heat Pump Water Heater

Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)

 

PHNIX Air Source Heat Pump is specially designed for house heating in cold area. The evaporator is 30% bigger than normal, which could ensure high efficiency and better performance in low ambient temperature. According to the test, it could work safely in -15oC, and reach COP 3.5 in practical working condition.

 

FEATURES

1) Base frame and external panels made of galvanized powder coated steel

2) Extremely compact structure, easy demountable for access

3) High efficiency compressor with R410A Refrigerant

4) Reverse cycle valve

5) Intelligent controller and adjustment by quickmind microprocessor with possibility of remote control(Carel controller for standard)

6) Water side equipped with EST high efficiency exchanger

7) Air exchanger (fins-coil) with hydrophilic coating

8) Automatic defrosting function included

9) Thermostatic heating element for evaporator anti-frosting protection

10) Thermostatic expansion valve

11) General testing and operational test carried out for every unit before package in the factory

 

Optional

Additional water storage tank

Stainless steel case

Wireless controller

 

CERTIFICATIONS
CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, SASO, VDE, RoHS, REACH, EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, ISO9001, ISO14001, Six Sigma, Lean Production and Management   

 

Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL) 

KK Series (Monobloc)

 

PASRW

020B-C

030B-C

040B-C

050B-C

060B-C

080B-C

*Heating Capacity

kW

6.0

8.2

14

15

17

24

 

BTU/h

20400

27880

47600

52000

60000

81600

*COP

W/W

4.00

4.10

4.15

4.2

4.15

4.15

**Heating Capacity

kW

6.1

8.3

13

14

16.5

22

 

BTU/h

20740

28220

44200

47600

56100

74800

**COP

W/W

3.21

3.26

3.24

3.26

3.23

3.25

Cooling Capacity

kW

5.1

7.1

10

11.5

13.5

19.5

 

BTU/h

17340

24140

34000

39000

46000

66500

EER

W/W

2.85

2.84

2.85

2.8

2.86

2.8

Power Supply

V/Ph/Hz

230V~/50Hz

Compressor

/

Rotary

Net Dimensions(L/W/H)

mm

1160/426/840

1110/440/1350

1350/515/1450

Shipping Dimensions(L/W/H)

mm

1240/446/670

1190/460/1380

1430/580/1580

*Heating: Ambient temp.(DB/WB): 7°C/6°C, Water temp.(In/Out): 30°C/35°C;

**Heating: Ambient temp.(DB/WB): 7°C/6°C, Water temp.(In/Out): 40°C/45°C;

Cooling: Ambient temp.(DB/WB): 35°C/24°C, Water temp.(In/Out): 12°C/7°C.

The above data is for reference only: specific data is subject to the product nameplate.

 

Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)Geyser Heat Pump Water Heater(EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, CE, ETL, CETL)

 

All PHNIX heat pumps are processed with strict management system to ensure the quality and consistency. All the products like swimming pool heat pumps, heat pump water heaters, sell well in the global market.

There are processing documents for each operating post in detail and all the daily manufacture dates will be analysed through the manufacture data base system and shown on the white board set in the workshops to improve the operation skills of our workers.

As the development of company, more and more advanced production modes were adopted in PHNIX, such as 7S and lean manufacturing, which made the production more exact and efficient.

The leading manufacturing methods from Europe and North America are applied to our production line and we always focus on the detailed processing steps such as welding, cutting and insulation to ensure superior quality of our products.

 

Formulated the following quality policy and quality objectives, is now officially promulgated, all staff have to study and understand clearly, and effectively implement

 

The company's quality policy is: scientific management and ensure quality; to be the best and make customer satisfied.

The company's quality objectives are: to ensure that the finished product qualification rate reached 100%; strive to major quality accidents to zero.

 

Every unit wll be well packaged before stuffing to ensure there is no shaking during the shipping.Before shipping the packaged unit will stored in the factury storage where has

In order to ensure the company's quality management system operated effectively, and continuously improve  our product quality and services.

  

 

 

 

Contact Supplier

Mr. Forrest Mo Oversea Dept Directo Chat Now
Telephone
86-20-34990472
Mobile
0086-13711380759
Fax
86-20-34990473
Address
NO.3 Tianyuan Road,Dagang Town,Nansha, Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Home Appliances > Water Heaters > Heat Pump Water Heaters
Categories
Hi~