Heat Pump DC
PHNIX Heat Pump DC with compressor and water system in indoor unit, which ensure a better anti-freezing protection and lower heat dissipation or loss. The application of green refrigerant R410A makes the unit do no harm to the ozone layer and environmentally-friendly. Moreover, the unit have a good performance under the low air temperature down to -15 degree and COP still up to 4.0. Wireless controller design is more hommization and more easy control for users. Therefore, it enjoys good sale in foreign and domestic market.
FEATURES
1. The patented high efficiency heat exchangers which with strong countercurrent design, are helpful for improving the efficiency and not easy to freeze and scaling for the heat pumps.
2. Anti-freezing protection of the units ensures stable operation.
3. Automatic compensation technology can adjust the setting temperature according to the ambient temperature to satisfy the heating demand from the customers.
4. The capacity control function ensures the units adjust the actual output capacity according to the real demand required from the terminals to make comfortable temperature for your room.
CERTIFICATIONS
CE, CB, EC, ETL, CETL, C-TICK, WATER MARK, STANDARD MARK, UL, SABS, SANS, SAA, SASO, VDE, RoHS, REACH, EN14511-2:2011, EN14511-2:2007, NFPAC, EURO-VENT, ENERGY-STAR, DOE, ISO9001, ISO14001, Six Sigma, Lean Production and Management
KK Series (Monobloc)
PASRW | 020B-C | 030B-C | 040B-C | 050B-C | 060B-C | 080B-C | |
*Heating Capacity | kW | 6.0 | 8.2 | 14 | 15 | 17 | 24 |
BTU/h | 20400 | 27880 | 47600 | 52000 | 60000 | 81600 | |
*COP | W/W | 4.00 | 4.10 | 4.15 | 4.2 | 4.15 | 4.15 |
**Heating Capacity | kW | 6.1 | 8.3 | 13 | 14 | 16.5 | 22 |
BTU/h | 20740 | 28220 | 44200 | 47600 | 56100 | 74800 | |
**COP | W/W | 3.21 | 3.26 | 3.24 | 3.26 | 3.23 | 3.25 |
Cooling Capacity | kW | 5.1 | 7.1 | 10 | 11.5 | 13.5 | 19.5 |
BTU/h | 17340 | 24140 | 34000 | 39000 | 46000 | 66500 | |
EER | W/W | 2.85 | 2.84 | 2.85 | 2.8 | 2.86 | 2.8 |
Power Supply | V/Ph/Hz | 230V~/50Hz | |||||
Compressor | / | Rotary | |||||
Net Dimensions(L/W/H) | mm | 1160/426/840 | 1110/440/1350 | 1350/515/1450 | |||
Shipping Dimensions(L/W/H) | mm | 1240/446/670 | 1190/460/1380 | 1430/580/1580 | |||
*Heating: Ambient temp.(DB/WB): 7°C/6°C, Water temp.(In/Out): 30°C/35°C; **Heating: Ambient temp.(DB/WB): 7°C/6°C, Water temp.(In/Out): 40°C/45°C; Cooling: Ambient temp.(DB/WB): 35°C/24°C, Water temp.(In/Out): 12°C/7°C. The above data is for reference only: specific data is subject to the product nameplate. |