HYA copper telephone telecommunication cable&wire
Negotiable /Meter
Min.Order:50000 Meters
Shenzhen Runxiang Telecommunication Technology Co., Ltd.
Description of In-city communication cable HYA
1) 0.5 mm pure copper conductor
2) HDPE insulation, The insulated lines are separated by 10 colors according to the standard requirements.
3) Insulated single line: solid polyolefin insulated single line. The insulated lines are separated by 10 colors according to the standard requirements.
4.) Insulated pair lines: wring two single lines together with different pitches according to the chromatogram composition that required.
5). Cable core cover belts: the cable core is covered by polyester film or film belts, and wrapped steadily by the polyester yarn.
6). Shielding: usually use Aluminum belts.
7). Layer: the shielding layer is covered by the low density polyethlene film which contains the 2.5±0.5% carbon black in it, thus formed a good damproof layer.
8). ADSS Cable: add an aerial cable on the base of HYA, can be overhead.
9). Features: aerial cable.
10). Applications: voice communication.
11) Packing: 1,000 meters / box or according to the buyer's requirement
ITEM | UNITS | INDEX | |||||||||||||||||||||||||||||||||
Single-wire DC resistance of Max. +20°C | Ω/km | Conductor Diameter(mm) 0.32 0.40 0.50 0.60 0.70 0.90 236 148 95 65.8 48 29.5 | |||||||||||||||||||||||||||||||||
wire of DC the resistance unbalance +20°C (the average not larger than the maximum) | % | 2.5 1.5 1.5 1.5 1.5 1.5 6 5 5 5 5 4 | |||||||||||||||||||||||||||||||||
Insulation resistance of the minimum +20°C Between each insulated conductor and other grounded and shielded insulated conductors | MΩ.km | Non-filling filling ≥10000 ≥3000 | |||||||||||||||||||||||||||||||||
Insulation electric strength Between the wires(3s/60s) Between the conductor and the shield(3s/60s) | kV | 2.0/1.0 6.0/3.0 | |||||||||||||||||||||||||||||||||
Working capacitance Below 10 pairs of cable:average/maximum over 10 pairs of cabel:average/maxium | nF/km | 52.0+-2.0/57.0 52.0+-4.0/58.0 | |||||||||||||||||||||||||||||||||
capacitive unbalance Between wire and wire:maxium Between wire and ground:small average Between wire and groud: maxium | pF/km | 0.32 0.4 0.5 0.6 0.7 0.9 250 250 250 200 200 200 570 570 570 490 490 490 2630 | |||||||||||||||||||||||||||||||||
Inherent attenuation Cable more than 10 pairs of non-filling: 150kHz Average ≤ 1024kHz Average ≤ Cable more than 10 pairs of filling: 150kHz Average ≤ 1024kHz Average ≤ | db/km | 0.32 0.4 0.5 0.6 0.7 0.9 16.8 12.1 9 7.2 6.2 4.8 33.5 27.3 22.5 18.5 15.8 12.6 16 11.7 8.2 6.7 5.7 4.4 31.1 23.6 18.6 15.8 13.5 10.4 | |||||||||||||||||||||||||||||||||
Near-end crosstalk All the combination between the pairs of wire in 10 pairs and below of cable All the combination between the pairs of wire in 20 or 30 pairs and the basic unit All the combination between the pairs of wire in adjcent to the basic unit Super-unit, two relatively basic units of all combinations Different super-flat line for all combinations of the basic unit FEXT defense degree 150kHz Any wire pairs of combined The basic unit or 30 pairs of the cable inside between groups All the combination between the pairs of wire below in 20 pairs of cable | db |
≥53 ≥58 ≥64 ≥64 ≥79 Minimum ≥58 Power average ≥69 Power average ≥68 | |||||||||||||||||||||||||||||||||
Shielding of the continuity of the ribbon | continue | ||||||||||||||||||||||||||||||||||
Cores mixed wire ,wire break | Not mix,break |