Theodolite Electronic Magnification 30X Code: DT02
USD $400 - $450 /Set
Min.Order:1 Set
L&T Mechanical & Electrical Equipment Co., Ltd.
Theodolite Electronic Magnification 30X Code: DT02
We Manufacture. Distribute. Service
L&T 20-Year Export Experience
Reliable and accurate angle measurement is easy with the DT-02 electronic theodolite, it benefits from simple operating functions and a large, clear display.
Ÿ Accurate to 2 sec of arc. You also can choose 5 sec / 10 sec /20 sec
Ÿ Reads to 1 sec of arc
Ÿ Erect image
Ÿ Stadia hairs for distance measuring
Ÿ Built in optical plummet
Ÿ Dual backlit displays
Ÿ Horizontal and vertical tangent drives
Ÿ Zero set and hold function
Ÿ Percent or degrees on vertical circle
Ÿ Rechargeable batteries
Ÿ RS-232C port allows data to be transferred by cable
Specification
Technical data | DT-02 | |||
Telescope | Erect Image | |||
Objective aperture | 45mm | |||
Magnification | 30× | |||
Resolution power | 3.5" | |||
Shortest focussing distance | 1.4m | |||
Field of view | 1° 30' | |||
Display(s) | 2 | |||
Angle measurement | 360° | |||
Incremental minimum reading | 1" | |||
Accuracy (DIN18723) | 2" | 5" | 10" | 20" |
Level Sensitivity | ||||
Plate level | 30" per 2mm | |||
Circular level | 8" per 2mm | |||
Optical plummet | ||||
Magnification | 3x | |||
Focussing range | 0.5m to infinity | |||
Output standard | RS-232C | |||
Power supply | NiMH | |||
Operating time | 14hrs | |||
Temperature range | -20°to + 50 ℃ | |||
Weight | 4.5kg | |||
Dimensions | 165 x 155 x 320mm |
Sample Picture
Mode Setup Procedures
Before the instrument is delivered, initial set mode is: 360º system in angle unit, minimum reading
of 1″, disabled power off, zenith angle for vertical angle mode, and enabled vertical axis tilt
compensation function.
Assume the modes to be set as follows: 400 Gon system in angle unit, minimum reading of
1 mGon (5″), automatic power off in 30 minutes, height angle for vertical angle mode, and disabled
vertical axis tilt compensation function. Proper setup procedures are described as follows:
1. Start up the instrument, and vertical angle crosses zero.
2. Press key and key simultaneously, and the instrument will go to the state of mode setup. In LCD,
the upper left row is minimum reading, for instance, 1″ or 5″ in 360º system, and 0.5 or 1.0 mGon in 400
Gon system. The lower left row is automatic power off constant, for instance, 0 for disabled power off, 20
for 20 minutes, 30 for 30 minutes. The lower right row is vertical angle measurement modes, for instance,
Ua for zenith angle, Ub for vertical angle, and Uc for height angle. The middle part indicates enabled
compensation function. When the function is disabled, no indication exists.
3. Press key to change the number (400 Gon) in the upper right row. Repeatedly press it to alternate 360
and 400.
4. Press key to change the number (1.0 Gon) in the upper left row. Repeatedly press it to alternate 0.5
and 1.0 (Gon) or 1 and 5 (″).
5. Press key twice to change the symbol of Ua into Uc in lower right row. Repeatedly press it display Ua,
Ub and Uc by turn.
6. Press key twice to change the number 30 in lower left row. Repeatedly press it display 0, 20 and 30
by turn.
7. Press key, and the TILT will disappear and the tilt compensator will be shut down. Repeatedly press
it to disable or enable the compensation function.
8. After completing the above settings, press key and key simultaneously, and the instrument will record
new settings and return to the state of angle measurement.
Theodolite Electronic Magnification 30X Code: DT02