self regulating 220V heating cable
USD $0.15 - $0.55 /Meter
Min.Order:10000 Meters
Shenzhen Runxiang Telecommunication Technology Co., Ltd.
self regulating 220V heating cable
Electrical parameters
1.Rated voltage: 220V 50Hz (voltage can be customized)
2.Pressure:300/500V
3.Linear power:17W/M,18W/M,20W/M
4.Cold wire length:2 Root × 2.25m
5.Minimum bending radius:5×Cable diameter
Product structure
Heating Conductor | Shield | ||
Material | Copper-nickel alloy | Outside insulation | |
Form | Patch | Polyester belt form | Longitudinal layer of polyester |
Number | 7 Root | Polyester material | PET |
Diameter | Φ 0.30±0.02 mm | Polyester belt specifications | 0.25×12 mm |
Cable Core | 1 Core | Braid material | TC - Tinned Copper |
Insulation | Braid | 16×3×TCΦ0.10 mm | |
Material | Silicone rubber | Covered | ≥ 35% |
Thickness | 1.00±0.05 mm | Braid outside | |
Diameter | Φ 3.00±0.10 mm | Polyester belt form | Longitudinal layer of polyester |
Number and color | 1 Root:Transparent Color | Polyester material | PET |
Marking | Per Customer Request | Polyester belt specifications | 0.25×14 mm |
Outer Jacket | |||
Material | PVC - Polyvinyl Chloride | Thickness | 1.35±0.05mm |
Color | Blue & Red | Diameter | 6.50 +/- 0.30 mm |
Electrical Performance
Reference Standard:
1.JGJ 142—2004 Technical specification for floor radiant heating
2.IEC 60800:1992 Rated voltage 300/500V heating cable for life
facility heating and guards against
Test Items Unit Spec
1.Product temperature cable voltages 2.0 kV/5min No breakdown
2.Product temperature cable voltages (100 °C) 1.5 kV/15min No breakdown
3.Min.Subsequent insulation resistance (100°C) MΩ·km 0.03
4.Standard resistor errors (20°C) Ω/m -5% ~ +10%
5.Temperature coefficient of resistance Should be a positive number
6.Maximum grounding resistance (20°C) Ω/m ≤0.0181
7.Continuity of conductors, shielded — Continuous