50KW Resistive Load bank
USD $3,000 - $4,000 /Set
Min.Order:1 Set
Shanghai Lingguang Electric Apparatus Manufacturing Co., Ltd.
Shanghai Lingguang Electric Apparatus Manfacturing Co.,LTD (Lingo)established in 1991.
Professional industrial electrical products -- resistance box, load box, center grounding resistance, manufacturers in domestic resistor manufacturing enterprises have higher visibility.
With nearly 150 employees, scientific and technical force is abundant, has many national patents (Example: ZX18V type resistors, patent number 03230790).
Had including CNC plate shears, CNC folding machine, CNC punching, more than 60 sets of large-scale processing equipment.
Enterprise through IS09001 quality system, ISO14001.2004 environmental management system and GB/T2800-2001 worker health and safety management system.
LINGO widely used in steel, electric power, ship, railway, electronics, and etc, the products have been exported to Japan, France, Germany, Egypt, etc.
LINGO is located in Shanghai PuDong new area, has a total area of about 9,000 square meters workshops, warehouses and office center.
Excellent ability of research development
The advanced production processing equipment
Complete production assembly processing capacity
Perfect quality guarantee system
Quickly logistic support capacity
Timely and efficient service response
Enterprising management team
With first-class product quality to win the trust of customers
With first-class marketing quality to win the confidence of users
With first-class service quality to win the satisfaction of customers
50 KW load bank :
1 Resistance load equipment: 50KW
2 Power factor: 1.0
3 Test voltage: three phase AC voltage 400V
4 Frequency: 50--60Hz
5 Active power step:
1KW X 5 2KW X 3
3KW X 2 5KW X 3
10KW X 2
6 Normal Operational Conditions
In summer the ambient temperature is 45,humidity is 90%.In winter the ambient temperature is -20, humidity is 50%
7 ventilation power and the control power of the load bank are single phase 3 wire ( 220V + N + PE), total control power is 1 KW.
8 Cooling mode: forced air convection, the fanner with axial-flow, the direction of the air is coming from the bottom and outgoing from the above.
9 Controlling mode: Manual control.
10 Load bank rated power error: thermal state: -4, cold state: -2.
11 Protection device: over-current, short-current, over-load protection for the fanner.
12 the temperature for load bank outlet is 250-300
13 IP for main return circuit: IP23
14 Insulation degree for motor: F
Insulation degree for load main return circuit and control return circuit: F
15 Working mode: continuous
16 Weight: 180KG