precision LCR meter
precision LCR meter
precision LCR meter

precision LCR meter

USD $0.1 - $1,660 /Set

Min.Order:1 Set

Supply Ability:
5000 Set / Sets per Month
Port:
XIAMEN
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Fujian, China
Brand Name:
SANSHINE
Model Number:
SS1061

Sanshine (Xiamen) Industrial And Trading Co., Ltd.

Credit Member 4 years
Business Type: Trading Company
Xiamen Fujian China
Main Products: winding machine Transformer tester ,toroidal winding machine ,amorphous ribbon produce machine Cable tester ,soldering pot HI-POT tester Glue dispenser ,LCR meter Turns tester

Product Details

 SS1061 precision LCR meter  
Product Description

  

Description of SS1061/1062/1063 LCZ / LCR Meters :
SS1061/ SS1062 / SS1063 precision LCR meter  are a test system for passive components designed for the use in electronic inspection or production process for quality control. They meet any demanding requirement on production speed and precision, discrimination of qualified products from unqualified ones, as well as internal setup, storing and calling function for up to 10 instrument groups, so they are actually optimum test instruments for component incoming and production inspection.

Key Features of SS1061/1062/1063 precision LCR meter :
Test frequency:  40Hz~200kHz
Basic measurement accuracy:  0.1%
Single-function Keys,  LED display,  easy to operate
LCR Nominal Value,  Upper Limit%,  Lower Limit%,  Q / D / R / E Limit thumb switches setting(1062 only).
10 internal Instrument setups store / recall capability(1063 only).
L: 0.0001uH ~19999H;  C: 0.0001pF~199.99mF;  Z: 0.0001Ω~199.99MΩ;  Q/D: 0.0000~10000
θ :  -180deg ~  +179.99deg;  ESR: 0.0001MΩ~19999kΩ,
Testing Voltage: 10mV~1.0V, 10mV/step,

 

Order Items of SS1061/1062/1063 precision LCR meter :
SS1061
SS1062
SS1063
4-terminal test fixture
Test pen
Test box
SMD test wire

Order project of SS1061/1062/1063 precision LCR meter :
1061
1062
1063
Four-terminal Test wire Clamp(within tester)
Test Pen(optional)
Test Box(optional)
SMD Test Cable(optional)

  

Specification of precision LCR meter :

 

 

ModelSS1061SS1062SS1063
Test parameter
Main displayL  , C,   R, Z
Subaltern displayQ  , D  , ESR  , θ
Measure. signal
Meas. Level10mV~1.0V, 10mV/step
Meas. Frequency40HZ~ 200KHZ, 30steps
Frequency accuracy± 0.01%
Out impedance100mA± 5% , (1V seting ), Impedance ≤10Ω,  2Ω± 10%,  ≥ 10Ω  
Measure Range
Main parameterL(0.0001uH ~ 19999H), C(0.0001pF~199.99mF) , Z(0.0001Ω ~199.99MΩ )
Subaltern parameterQ, D(0.0000~ 10000), θ (-180.00° ~ +179.99° ), ESR(0.0001mΩ ~ 19999KΩ)
Base accuracy0.10%
Measure speed  ( 1KHZ )
Fast8 Meas. /S
Slow2.5 Meas. /S
Triggerinternalinternal, external, manual
Display
L, C, Z, R5pcs digitals
Q, D, R, θ5pcs digitals
Frequency, level3pcs digitals
External DC baseDC: 0~35V
Revising functionopen, short
Equivalent circuit modelin series  , parallel
Automatic judgement pass or fail
Memory 10Groups seting
Common spec.
Environmenttemperature  : 10  º C ~ 40  º C, humidity  : 10%~90%RH
Power consumingMax. 55W
Power90~125V or 190~250V, 48HZ~62HZ
Weight≈ 5.5Kg≈ 6.5Kg
Meas.( W× H× L  )270× 105× 350mm405× 130× 365mm

Pictures of  SS1061 precision LCR meter 

precision LCR meter

 

precision LCR meter

 
Our Services

  

Service tenet

 

Provide you the best service with “fast + satisfactory + safe”.

 

Warranty period

 

12 months long after the user received the product.

 

Warranty items

 

Only for abnormal breakdown caused by the machine design or manufacture defect,

 

free repair and accessory will be provided.

 

Technology service ability

 

All service engineers with many years experience are gotten special technology training, who can deal with various breakdown problem.

 

Guide the user to use accurately and how to maintain the product.

 

Provide free consultation about production process technology of electronic products.

 

Service after sell

 

In order to guarantee the machine used normally, we’d have training on how to operate, use and maintain our product by English manual, video, guiding on line.

 

Use instruction

 

Apply for the right complete size of product, otherwise, the wrong dimensions will affect the use effect.

 

Do ensure using the product accord to the use instruction completely.Do not exceed the scope of application of the products.

 

Maintain the product after use,Damp proof, rust proof, leak proof, explosion-proof, regular maintenance and inspection should    

 

be taken care. All done help to extend the use period.

 

User document management

 

Establish perfect user document management in EPR system, Every product running details would be followed to manage.    The users would be taken good care.

 

About product

 

1. Product photo: All product photos are taken by real product, There is the color aberration between the product and photo, which is caused by shoot light, product size, manual technology and computer display etc. It’s not quality problem. Parts of products are changed in appearance due to technology revolutionary and process improvement. SanShine would ensure the parameter of product is unchanged, The product couldn’t affect to use.

 

2.Product size: All parameters are all measured by manual just for reference. There is a small deviation due to the difference of measure tools, lot products and produce process. Real size should be accordance with the final delivery product.

 

3.Quality inspection: All products should be inspected strictly before shipment. Ensure the good function and appearance.

 

 

 

 

Packaging & Shipping

 

Package and transport

 

General package(Paper carton or plastic bag):  For small goods, Package it with form and pack paper to guarantee unbroken during the transport.

 

Wooden case package: For larger scale goods as machine equipment etc, we have special skilled carpenter, who would make the proper wooden case with exact thickness,density,length. The up arrow ↑marked on the outer wooden case. Buffer material would be put in the wooden case to prevent crack and shock. We will inform you the delivery note. You just need to wait for phone call, then pick up the goods at the nearest logistic station .(Please let me know in advance if you want get the goods at home.)

 

precision LCR meter

 

 

 

 

 

Company Information

 

precision LCR meter

 

 


 

Contact Supplier

Ms. Ivy Zhuo Sales manager Chat Now
Telephone
0086-592-6603065
Mobile
008613779958581
Fax
0086-592-3761682
Address
NO.2 XIAMEI ROAD,XINYANG INDUSTRY ZOON,HAICANG Xiamen,Fujian

You May Like

New Products

Find Similar Products By Category

Measurement & Analysis Instruments > Electronic Measuring Instruments > Other Electronic Measuring Instruments
Categories
Hi~