Glass tube gas/water /medical flow meter/ rotameter
Glass tube gas/water /medical flow meter/ rotameter
Glass tube gas/water /medical flow meter/ rotameter
Glass tube gas/water /medical flow meter/ rotameter
Glass tube gas/water /medical flow meter/ rotameter
Glass tube gas/water /medical flow meter/ rotameter

Glass tube gas/water /medical flow meter/ rotameter

USD $19 - $817 /Set

Min.Order:1 Set

Supply Ability:
150 Set / Sets per Month
Port:
DALIAN or TIANJIN

Quick Details View All >

Place of Origin:
Liaoning, China
Brand Name:
BEIXING
Model Number:
LZB

Shenyang Beixing Meter Manufacture Co., Ltd.

Credit Member 4 years
Business Type: Manufacturer,Trading Company
Shenyang Liaoning China
Main Products: glass rotameter ,balanced flow meter ,Flow & Temperature monitor ,plastic pipeline flow meter ,magnetic turning level meter

Product Details

 

 

 

Product Description

Glass tube gas/water /medical flow meter/ rotameter 

 

 

Trade Shows 2

 

Glass tube gas/water /medical flow meter/ rotameterGlass tube gas/water /medical flow meter/ rotameterGlass tube gas/water /medical flow meter/ rotameter

 

 

 

 LZB Glass tube gas water  medical flow meter rotameter

 

General information

LZB glass pipeline flow meter is used for liquid, gas and many other single applications measuring, it’s a low cost measuring equipment and simple in structure, operation and high accuracy in measuring, easy for maintenance and repairing. It is wildly used in chemical industry, chemical fiber, fertilizer, petroleum, pharmaceutical, metallurgy, dyes, paper, food, water treatment and environmental research.

 

Measuring theory

The movable float is fitted in a cone shaped vertical glass pipeline. It will move when application flow through from bottom to the top. It stays at a position when the float is balance on gravity, buoyancy and viscous forces together, and the current position is stand for the current flowing rate.

 

Basic parameters

LZB glass pipeline flow meter main parameter show as blow:

 

Bore

(DN)

Type

Measuring range

Accuracy

Allowed application status

Water (ml/min)

Air(ml/min)

Temp (°C)

Pressure(MPa)

2

LZB-2

0.4-4; 1-10

0.6-6; 1.6-16

6-60; 16-160

10-100; 25-250

4

0~+120

≤0.1

3

LZB-3

2.5-25; 6-60

4-40; 10-100

40-400; 100-1,000

60-600; 160-1,600

 Glass tube gas/water /medical flow meter/ rotameterGlass tube gas/water /medical flow meter/ rotameter

 

Bore

(DN)

Type

Measuring range

Accuracy

Application status

Water

(L/h)

Air

(m3/h)

Temp (°C)

Pressure (MPa)

4

LZB-4

1-10; 1.6-16; 2.5-25

0.016-0.16; 0.025-0.25; 0.04-0.4

4

0

|

|

|

+120

≤1

6

LZB-6

2.5-25; 4-40; 6-60

0.04-0.4; 0.06-0.6; 0.1-1.0

2.5

10

LZB-10

6-60; 10-100; 16-160

0.1-1.0; 0.16-1.6; 0.25-2.5

15

LZB-15

16-160; 25-250; 40-400

0.25-2.5; 0.4-4;

0.6-6; 1-10

≤0.9

25

LZB-25

40-400; 60-600; 100-1,000

1-10; 1.6-16; 2.5-25

1.5

40

LZB-40

160-1,600; 250-2,500

4-40; 6-60

≤0.6

50

LZB-50

400-4,000; 600-6,000

10-100; 16-160

80

LZB-80

1,000-10,000; 1,600-16,000

50-250; 80-400

100

LZB-100

5,000-25,000; 8,000-40,000; 20,000-60,000; 60,000-70,000; 30,000-80,000

120-600; 200-1,000

 

Installation and operation____________________

The installation of the flow meter:

  1. There should be enough room available around the equipment for easier maintenance.
  2. For calibration, repair, changing and cleaning of the equipment, by-pass should be fitted along the equipment. (see below picture for detail)
  3. The pipeline should be cleaned for the first time installation.
  4. The pipeline should be immovable before installation of the equipment to prevent damage.
  5. One way check valve should be installed at downstream of the equipment to prevent equipment damage from countercurrent, especially water v-cone.
  6. Filter should be installed at upstream of the equipment when application content particles and dirt to prevent blocking of the pipeline.
  7. Suitable buffer or amount setting device should be installed at upstream of the equipment when the application is in pulsating flow to prevent shaking of the float.
  8. The flow meter should be installed vertically.
  9. Valve should be fitted at upstream and flow control valve should be installed at downstream at 5~10 times distance of the bore size.
  10. The minimum calibration line should be at the bottom when installing.

Glass tube gas/water /medical flow meter/ rotameterGlass tube gas/water /medical flow meter/ rotameter

 

 

Company Information

Glass tube gas/water /medical flow meter/ rotameter 

 Glass tube gas/water /medical flow meter/ rotameter

 Glass tube gas/water /medical flow meter/ rotameter

    Shenyang Beixing Meter Manufacture Co., Ltd. was founded in August of 1995. We are located at Shenyang Economic & Technological Development Area and our company covers an area of 18,000sqm. Our company is specialized in manufacturing flow & level measuring instruments, chemical glass products, chemical glass pipes and special glass apparatus. Meanwhile, we also act as an agent of mechanical & electrical products, pressure instruments, chemical reagents, chemical materials, laboratory apparatus & science equipment, contract to design the instrument and meter engineering, chemical industry pipeline & laboratory auxiliary projects, process on given materials and take mechanical manufacturing.  Glass tube gas/water /medical flow meter/ rotameter

  Glass tube gas/water /medical flow meter/ rotameter 

Contact Supplier

Ms. Joy Liu International Tradin Chat Now
Telephone
86-24-25861622
Mobile
8613704008846
Fax
86-24-25612029
Address
No.80-2, Jianshe East Road, Tiexi Shenyang,Liaoning

You May Like

New Products

Find Similar Products By Category

Measurement & Analysis Instruments > Flow Measuring Instruments > Flow Meters
Categories
Hi~