Electronic Vehicle Charger &EV charging station
USD $3,000 - $5,000 /Set
Min.Order:1 Set
Shijiazhuang Tonhe Electronics Technologies Co., Ltd.
Electronic Vehicle Charger &EV charge station
Input 3 phase 380V or single phase 220V, output 30-100,100-750V DC, electric car charging, electric vehicle charger
Parameter | EV Charging Station Power Module | |||||||
TH400Q15NZ-220AC | TH350Q30NZ | TH450Q14NZ-A | TH750Q20NZ | TH90Q130NZ | TH92Q50NZ | TH80Q40NZ-S | ||
Input | Input voltage | 220V AC±15% | 380V AC±15%, 3 phase | 380V AC±15%, 3 phase | 220V AC±15% | |||
AC input frequency | 45Hz ~ 65Hz | 45Hz ~ 65Hz | ||||||
Efficiency | ≥90% | ≥92% | ≥93% | ≥92% | ≥92% | |||
Power factor | ≥0.99 (APFC), or ≥0.93 (PPFC) | ≥0.99 (APFC), or ≥0.93 (PPFC) | ||||||
Output | Output voltage | 50-500V | 150-350V | 300-450V | 40-90V | 60-96V | 30-80V | |
Output current | 5A | 30A | 14A | 20A | 130A | 50A | 40A | |
power | 2.5KW | 10KW | 6KW | 15KW | 12KW | 12KW | 3.2KW | |
Start delay | 3 ~ 8s | 3 ~ 8s | ||||||
Total harmonic current | ≤ 5% (APFC), or ≤ 30% (PPFC) | ≤ 5% (APFC), or ≤ 30% (PPFC) | ||||||
Current stabalization | ≤ ± 1% | ≤ ± 1% | ||||||
Voltage stabalization | ≤ ± 0.5% | ≤ ± 0.5% | ||||||
Inter-rectifier Current sharing imbalance | ≤ ± 3% | ≤ ± 5% | ≤ ± 3% | ≤ ± 5% | ≤ ± 3% | |||
Cooling method | Forced cooling with fan | Forced cooling with fan | ||||||
Protocal | RS485 and RS232, CAN | RS485 and RS232, CAN | ||||||
Protection | Multi-protection | Multi-protection including input over or under-voltage, output over or under-voltage, over-temperature, reverse connection, phase failure, and short circuit protection. The rectifier will shut down without output, and will return to normal operating after fault is cleared. | ||||||
Automatic current limiting | The output current will keep fixed without increase after it exceed the set point. | |||||||
Environment | Operation ambient temperature | -20°C ~ 50°C | ||||||
Storage temperature | -40°C~ 60°C | |||||||
Relative humidity | ≤ 90% | |||||||
Air pressure | 70 ~ 106kPa | |||||||
Safety | Insulation resistance | I/O to chassis and input to output >10MΩ (Test voltage: 500Vdc) | ||||||
Dielectric strength | Impose 2000Vdc between I/O and the chassis aftering shorting the input and output for one minutes. No breakdown or flashover | |||||||
Mechanical | Size (H × W × D) mm | 150×88 ×400 | 482×88 ×500 | 450×85 ×260 | 680×13 ×600 | 482×88 ×450 | 360×260 ×360 | 88×230 ×400 |
Weight | 8kg | 20kg | 10kg | 46kg | 20kg | 10kg | 5kg |
Main Features:
1. Accounts managements. 2. Billing function.
3. Card reading and writing. 4. Man-machine interface
5. Language reading sound 6. Deal data storage
7. Operation monitoring 8. Self-checking
9. Parameter setting 10. Safety protection
11. Time recording 12. Software upgrading
13. Time revise 14. Encryption function
15. Card writing function after power-off.
Parameter | Integrated EV Charging Station | |||
THEV350V300A | THEV500V200A | THEV750V150A | ||
Input | Input voltage | 380V AC±15%, 3 phase | ||
AC input frequency | 45Hz ~ 65Hz | |||
Efficiency | ≥92% | |||
Power factor | ≥0.99 (APFC), or ≥0.93 (PPFC) | |||
Output | Max output voltage | 350V DC | 500V DC | 750V DC |
Max output current | 300A | 200A | 150A | |
power | 105KW | 100KW | 112.5KW | |
Start delay | 3 ~ 8s | |||
Total harmonic current | ≤ 5% (APFC), or ≤ 30% (PPFC) | |||
Current stabalization | ≤ ± 1% | |||
Voltage stabalization | ≤ ± 0.5% | |||
Current sharing imbalance for Rectifiers Parallel | ≤ ± 5% | |||
Cooling method | Forced cooling with fan | |||
Protocal | RS485, RS232, CAN | |||
Protection | Multi-protection | Multi-protection and Warning, including input over or under-voltage, output over or under-voltage, over-temperature, reverse connection, phase failure, and short circuit protection. The rectifier will shut down without output, and will return to normal operating after fault is cleared. Output DC voltage and current adjustable, output over or under-voltage set-point adjustable, output over-current set-point adjustable | ||
Automatic current limiting | The output current will keep fixed without increase after it exceed the set-point, set-point adjustable. | |||
Environment | Operation ambient temperature | -25°C~ 75°C' | ||
Storage temperature | -25°C~ 75°C' | |||
Relative humidity | ≤ 90% | |||
Air pressure | 70 ~ 106kPa | |||
Safety | Insulation resistance | I/O to chassis and input to output >20MΩ (Test voltage: 500Vdc) | ||
Dielectric strength | Impose 2500Vdc between I/O and the chassis aftering shorting the input and output for one minutes. No breakdown or flashover | |||
Mechanical | Cabinet Size (W × D × H) mm | 800×800×2260 | ||