high efficency pure sine wave ups 10kva to 30kva 3p/3p
USD $1269.00 - $1269.00 /Piece
Min.Order:1 Piece
Shenzhen Apcups Power Co., Ltd.
3 phase in 3 phase out long time back up online ups
True double-conversion
DSP technology guarantees high performance
Output power factor 0.8
Wide input voltage range (110-400 VAC)
Active power factor correction in all phases
50Hz/60Hz frequency converter mode
Eco mode operation for energy saving (ECO)
Accepts dual power inputs
Emergency power off function (EPO)
Generator compatible
SNMP+USB+RS-232 multiple communications
3-stage extendable charging design for optimized battery performance
Adjustable battery numbers
Maintenance bypass available
Optional N+X parallel redundancy
Optional isolation transformer offers full isolation and complete common mode noise rejection
MODEL | 3/3-10K (L) | 3/3-15K (L) | 3/3-20K (L) | 3/3-30K (L) | |
PHASE | 3 phase in / 3 phase out | ||||
CAPACITY | 10000 VA / 8000 W | 15000 VA / 12000 W | 20000 VA / 16000 W | 30000 VA / 24000 W | |
INPUT | |||||
Nominal Voltage | 3 x 400 VAC (3Ph+N) | ||||
Voltage Range | 305-478 VAC (3-phase) @ 100% load 190-520 VAC (3-phase) @ 50% load | ||||
Frequency Range | 46~54 Hz or 56~64Hz | ||||
Power Factor | 0.99 @ 100% load | ||||
OUTPUT | |||||
Output Voltage | 3 x 400 VAC (3Ph+N) | ||||
AC Voltage Regulation (Batt. Mode) | ± 1% | ||||
Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | ||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||
Current Crest Ratio | 3:1 (max.) | ||||
Harmonic Distortion | 2 % THD (Linear Load) 5 % THD (Non-linear Load) | ||||
Transfer Time | AC mode to Battery mode | zero | |||
Inverter to Bypass | zero | ||||
Waveform (Batt. Mode) | Pure Sine Wave | ||||
EFFICIENCY | |||||
AC Mode | 89% | 89% | 89% | 90% | |
Battery Mode | 86% | 88% | 87% | 89% | |
BATTERY | |||||
Standard Model | Battery Type | 12 V / 9 AH | |||
Numbers | 20 pcs (18 - 20 adjustable)** | 20 pcs (18 - 20 adjustable)**x 2 strings | 20pcs (18-20adjustable)** x 3 strings | ||
Typical Recharge Time | 9 hours recover to 90% capacity | ||||
Charging Current (max.) | 1A | 2A | 2A | 4A | |
Charging Voltage | 273 VDC ± 1%(based on 20 pcs batteries) | ||||
Long-run Model | Battery Type | Depending on the capacity of external batteries | |||
Numbers | |||||
Charging Current (max.) | 4A | 4A | 4A | 12A | |
Charging Voltage | 273 VDC ± 1%(based on 20 pcs batteries) | ||||
INDICATORS | |||||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||
ALARM | |||||
Battery Mode | Sounding every 4 seconds | ||||
Low Battery | Sounding every second | ||||
Overload | Sounding twice every second | ||||
Fault | Continuously sounding | ||||
PHYSICAL | |||||
Standard Model | Dimension, D X W X H (mm) | 815 x 250 x 826 | 815 x 250 x 826 | 815 x 250 x 826 | 815 x 300 x 1000 |
Net Weight (kgs) | 109 | 164 | 164 | 233.5 | |
Long-run Model | Dimension, D X W X H (mm) | 592 x 250 x 826 | 592 X 250 X 826 | 592 X 250 X 826 | 815 x 250 x 826 |
Net Weight (kgs) | 38 | 40 | 40 | 64 | |
ENVIRONMENT | |||||
Operation Humidity | 0-95 % RH @ 0- 40°C (non-condensing) | ||||
Noise Level | Less than 60dB @ 1 Meter | Less than 65dB @ 1 Meter | |||
MANAGEMENT | |||||
Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | ||||
Optional SNMP | Power management from SNMP manager and web browser |