singal phase 8000va ups power supply
USD $582.00 - $582.00 /Piece
Min.Order:1 Piece
Shenzhen Apcups Power Co., Ltd.
High quality online ups 10kva 220vac ,230vac ,110vac
True double-conversion on line UPS
DSP technology guarantees high performance
Output power factor 0.8
Standard backup UPS and long backup UPS in one integrated unit
Adjustable battery number from 16 pcs to 20 pcs
Adjustable charging current via LCD or software (0.5A~6A)
Wide input voltage range (110-300 VAC)
Active input power factor correction 0.99
50Hz/60Hz frequency converter mode
Emergency power off function (EPO)
3-stage extendable charging design for optimized battery performance
Maintenance bypass available
SNMP/USB/RS-232 communications
MODEL | 6K(L) | 10K(L) | |
PHASE | 1 phase in / 1 phase out | ||
CAPACITY | 6000 VA / 4800 W | 10000 VA / 8000 W | |
INPUT | |||
Nominal Voltage | 208/220/230/240VAC | ||
Voltage Range | Low Line Loss | 110 VAC ± 3% at 50% Load 176 VAC ± 3% at 100% Load | |
Low Line Comeback | 120 VAC ± 3% at 50% Load 186 VAC ± 3% at 100% Load | ||
High Line Loss | 300 VAC ± 3% | ||
High Line Comeback | 290 VAC ± 3% | ||
Frequency Range | 46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz | ||
Power Factor | 0.99 @ 100% load | ||
OUTPUT | |||
Nominal Voltage | 208/220/230/240VAC | ||
AC Voltage Regulation | ± 1% | ||
Frequency Range (Synchronized Range) | 46 Hz ~ 54 Hz or 56 Hz ~ 64 Hz | ||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||
Current Crest Ratio | 3:1 (max.) | ||
Harmonic Distortion | 3 % THD (Linear Load) 6 % THD (Non-linear Load) | ||
Transfer Time | Bypass to Inverter (Line mode) | Zero | |
Inverter to Bypass (Line mode) | Zero | ||
Waveform (Batt. Mode) | Pure Sinewave | ||
EFFICIENCY | |||
Line Mode | 89% | 90% | |
Battery Mode | 88% | 89% | |
BATTERY | |||
Standard Model | Battery Type | 12 V / 7 AH | 12 V / 9 AH |
Numbers | 16 | 16 | |
Typical Recharge Time | 9 hours recover to 90% capacity | ||
Charging Current | Default:1.0 A ± 10%, Max.:2.0A ± 10% | Default:1.0 A ± 10%, Max.:2.0A ± 10% | |
Float Charging Voltage | 218.4 VDC ± 1% | ||
Long-run Model | Battery Type | Depending on applications | |
Numbers | 16-20** (adjustable) | ||
Charging Current | Default:4.0 A ± 10%, Max.:6.0A ± 10% | Default:4.0 A ± 10%, Max.:6.0A ± 10% | |
Float Charging Voltage | 273 VDC ± 1% (based on 20 pcs batteries) | ||
INDICATORS | |||
LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||
ALARM | |||
Battery Mode | Sounding every 4 seconds | ||
Overload | Sounding twice every second | ||
Fault | Continuously sounding | ||
PHYSICAL | |||
Standard Model | Dimension, D X W X H (mm) | 369 x 190 x 688 | 442 x 190 x 688 |
Net Weight (kgs) | 60 | 75 | |
Long-run Model | Dimension, D X W X H (mm) | 369 x 190 x 318 | 442 x 190 x 318 |
Net Weight (kgs) | 21 | 23 | |
ENVIRONMENT | |||
Operation Humidity | 0-95 % RH @ 0- 40°C (non-condensing) | ||
Noise Level | Less than 55dBA @ 1 Meter | Less than 58dBA @ 1 Meter | |
Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | ||
Optional SNMP | Power management from SNMP manager and web browser |