price electromagnetic/ magnetic flow meter for oil / fuel
USD $100 - $500 /Piece
Min.Order:1 Piece
Xi'an Kacise Optronics Tech Co., Ltd.
price electromagnetic/ magnetic flow meter for oil / water
Description
GXEFM2000 electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.
There are two basic components of electromagnetic flow meter: 1) The Detector, which includes the flow tube, isolating liner and measuring electrodes, and 2) The Converter, which is the electronic device responsilbe for signal processing, flow calculation, display and output signals.
The materials of construction of the wetted parts( liner and electrodes) should be appropriate for the specification on the intended type of of service. Revies of the compatibilities consistent with the shipment of each meter.
Application field
Petroleum, Chemical, Metallurgy, Textile, Papermaking, Environmental protection, Food industry and Municipal administration, Water conservancy construction, Heating heating engineering, River dredging and other fields.
Technical Data
Measuring system
Measuring principle | Faraday’s law
|
Application range | Electircally conductive fluids |
Measured Value | |
Primary measured value | Flow velocity |
Secondary measured value | Volume flow |
Design
Features | Fully welded maintenance-free sensor |
Flange version with full bore flow tube | |
Standard as well as higher pressure ratings | |
Large diameter range from DN15~3000 with rugged liners approved for drinking water | |
Industry specific insertion lengths | |
Modular construction | The measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version |
Compact version | With 511B converter: 110~240Vac Power |
With 521B converter: 18~36V DC Power | |
With W800L/W800W: Battery Power | |
Remote version | In wall mount version with 211B converter (110~240Vac or 221B converter 18~36V DC |
With W800F converter: Battery Power | |
Measurement range | -12…+12m/s /-40...+40ft/s |
Measuring accuracy
Reference conditions | Flow conditions similar to EN 29104 |
Medium: water | |
Electrical conductivity: ≥300μs/cm | |
Temperature: +10~+30℃/+50~+80℉ | |
Inlet setion: ≥5DN | |
Operating pressure: 1Bar/14.5psig | |
Flow Meter Accuracy | Standard: 0.5% of rate |
Optional: 0.2% of rate |
Operating conditions
Temperature | |
Process temperature | Hard rubber liner: -5~+60℃ |
Polypropylene liner: -5~+90℃ | |
PTEF liner: -5~+120℃ | |
Ambient temperature | Standard (with aluminum converter housing) |
-20~+60℃ (Protect electorics againgst self-heating with ambient temperature above 55℃ | |
Stroage temperature | -20~70℃ |
Pressure | |
EN 1092-1 | DN2200~3000: PN2.5 |
DN1200~2000: PN6 | |
DN200~1000: PN10 | |
DN65~150: PN16 | |
DN10~50: PN40 | |
Other pressure on request | |
ISO insertion length | Optional for DN15~600 |
ASME B16.5 | 1~24”: 150lb RF |
Other pressure on request | |
JIS | DN10~1000/ 2~40”: 10K |
Other pressure on request | |
Pressure drop | Negligible |
Fluid | |
Physical condition | Conductive liquids |
Electrical donductivity | ≥5μs/cm |
Permissible gas content (volume) | ≤5% |
Permissible solid content | ≤70% |
Installation conditions
Installation | Take care that flow sensor is always fully filled |
For detailed information see chapter “Cautions for installation” | |
Flow direction | Forward and reverse |
Arrow on flow sensor indicates positive flow direction | |
Inlet run | ≥5 DN |
Outlet run | ≥2 DN |
Process connection
Flange | |
EN1092-1 | DN25~3000 in PN6~40 |
ASME | 1~120” in 150 lb RF |
JIS | 25~1000 in 10~20k |
Design of gasket surface | RF |
| Other sizes or pressure ratings on request |
Product picture