Digital pulse output heavy fuel oil flow meter
USD $80 - $200 /Piece
Min.Order:1 Piece
Xi'an Kacise Optronics Tech Co., Ltd.
Digital pulse output heavy fuel oil flow meter
Description of fuel oil flow meter
GXUF6000 series ultrasonic flow meter is ideal for flow surveys and closed pipe application where non-invasive measurement of liquids is required.
The advantages of high measurement accuracy, good consistency, battery power supply, easy operation and portability, make this meter the smallest and lightest flowmeter in domestic and a significant portable ultrasonic flow meter.
Features of fuel oil flow meter
Parameter of digital pulse output fuel oil flow meter
Handheld ultrasonic flow meter
Category | Performance | |
Host parameters | Principle | Transit time measure, 4 bytes of IEEE754 floating point arithmetic |
Accuracy | 1 % | |
Display | 320X240 pixel LCD, 4 x 8 or 4 x 16 Character matrix backlight LCD, support English, Italian, Chinese etc. | |
Output | 1 channel pulse output OCT (pulse width is adjustable | |
Data port | 1 channel isolated RS232 serial port. | |
Pipe request | Tube material | Steel, stainless steel, copper, aluminum, FRP, PVC, etc. |
Pipe diameter | 15~6000mm | |
Installation | If there is a bend, the sensor should be installed at a distance of 10D at least from the upstream bend, 5D at least from the downstream bend, and should be installed at a distance of 30D at least from the pumping hole. | |
Medium | Description | Clean water, sea water, industry water. Corrosive acid liquid and alkaline liquid, alcohol, beer, etc. |
Temperature | -30°C~160°C
| |
Turbidity | 10000ppm not so much baubles | |
Flow speed | 0 ~±10m/s | |
Working ambient | Temperature | Host: -20~60°C, Sensor:-30~160°C |
Humidity | Host: 85%, Sensor: IP67 | |
Electric source | 3 built-in 1.2V capacity rechargeable Ni-MH battery 2000mAH, each is full of electricity sustainable work more than 12 hours, the use of AC90 ~260V power adapter, can realize continuous measurement | |
Power dissipation | 1.5W | |
Shell material | Inflaming retarding ABS | |
Main engine weight | 390g |
Integral ultrasonic flow meter
Parts | Detail | |
Host part | Theory | Ultrasonic time gap |
Accuracy | ±1.0% | |
Option method | 4-keyboard support magnetic | |
Signal output | 1 channel 4~20mA @ 0.1% current loop back, the maxim load resistor up to 1000 ohm | |
1 channel OCT pulse output (default pulse width is 200ms, and can be modify between 6 to 1000ms) | ||
1 channel relay output (3A@220V) | ||
Signal input | 3 channel 4-20mA current loop back @0.1% circuit used to collect Temp. Pressure and liquid level etc. | |
1 channel mV input use to pt100 for calorimeter | ||
Digital port | RS485 support Mod-bus protocol and support firmware update | |
Cable | Special cable for RS485 the range up to 1000m | |
Suit pipe | Pipe material | Steel, cast iron cement, copper, PVC, Aluminum, glass, etc. |
Dimension | 15~6000mm | |
Sensor position | It is better the sensor fix at the position of at least 10D far away to stream, or 5D far away to stream, at least 20D far away from the pump outlet. | |
Suit flow | Medium | Water, sea water, waste water, liquid alcohol, beer, gas, oil, etc. |
Temperature | -30~160°C | |
Turbidity | 10000pm not so much baubles | |
Flow speed | 0~±10m/s | |
Environment | Temperature | Host: -20~60°C; Sensor: -30~160°C |
Humidity | Host: 85%RH; Flow sensor: IP68, less than 2m under water | |
Power supply | DC8~36V or AC85~265V(optional) | |
Consumption | 1.5W |
Ultrasonic flow Module&RTU
Parts | Parameters in detail | |
Host part | Theory | Ultrasonic time gap |
Accuracy | ±1% | |
Option method | 4-keyboard support magnetic rod operation | |
Signal output | 1 channel 4~20mA @ 0.1% current loop back, the maxim load resistor up to 1000 ohm | |
1 channel OCT pulse output (default pulse width is 200ms, and can be modify between 6 to 1000ms) | ||
1 channel relay output (3A@220V) | ||
Signal input | 3 channel 4-20mA current loop back @0.1% circuit used to collect Temp. Pressure and liquid level etc. | |
1 channel mV input use to pt100 for calorimeter | ||
Digital port | RS485 support Mod-bus protocol and support firmware update | |
Cable | Special cable for RS485 the range up to 1000m | |
Suit pipe | Pipe material | Steel, cast iron cement, copper, PVC, Aluminum, glass, etc |
Inner DN | 15~6000mm | |
Sensor position | It’s better the sensor fix at the position of at least 10D far away of upstream, or 5D far away of upstream, at least 20D far away from the pump outlet(D is the inner diameter of the pipe) | |
Suit flow | Media | Water, sea water, waste water, liquid alcohol, beer, gas, oil, etc |
Temperature | -30~160℃ | |
Turbidity | 10000pm not so much baubles | |
Flow speed | 0~±10m/s | |
Environment | temperature | Host: -20~60℃; Sensor: -30~160℃ |
Humidity | Host: 85%RH; Flow sensor: IP68, less than 2m under water | |
Power supply | DC8~36V or AC85~265V( optional) | |
Consumption | 1.5W |
Our Services
Sensor can be customized by your special request, We can supply technical consulting service for your user.
The quality principle: Quality is the best sales
Payment: We accept T/T, PayPal, Western Union, MoneyGram , Escrow
Shipping:
1. All parts will be shipped out within 1 - 3 working days after confirm the payment
2. DHL / FEDEX / UPS / EMS / TNT / China Post /Aramex
3. We are not responsible for force majeure accidents, delays or other issues, like the shipping service.
After-sales service
We can offer good technical support and good warranty for you after service as professional manufacturer.
Warranty: One year
During the warranty, if the goods after delivery are damaged with error caused only by itself quality problem, the goods can be returned for free repair and maintenance. however, if the goods is damaged with error caused by user’ s man-made and force majeure factor, we will be not responsible for free repair and maintenance.