Pipeline and Cable Locator
USD $2,600 - $4,700 /Unit
Min.Order:1 Unit
Shanghai Grandway Telecom Tech. Co., Ltd.
Description:
CL1400 Pipeline and Cable Locator consists of a Transmitter, a Receiver and Accessories, used in the underground pipeline & cable route accurate locating, the burial depth measuring, long distance tracing, and insulation fault point detecting. We adopted multicoil electromagnetism technology in CL1400 Pipeline and Cable Locator, enhanced the precision of the pipeline and cable location and the burial depth, and the goal pipeline identification capability. It could accurately carry on tracing and location to the goal pipeline and cable in the crowded pipelines and cables.
CL1400 Pipeline and Cable Locator is widely used in the telecommunication, mobile, electric power, water supply, natural gas, physical prospecting, petrochemical and city construction, etc.
Functions:
1. Detect the route of underground pipeline and cable
2. Measure the burial depth of underground pipeline and cable
3. Detect and locate the insulation fault point of the underground pipeline and cable
4. Identify the goal pipeline and cable under multiple underground pipelines and cables situation
Features:
1. Adopt the advanced signal processing technology and the latest integrated circuit to achieve outstanding test performance.
2. The detecting signal transmission method includes:
(1) Injection method: with injected the spot on the pipeline to detect the route and the burial depth, this method measuring accuracy is high, and good anti-jamming ability.
(2) Clamping method: used in a pipeline with the exposed section and easy to clamp.
(3) Induction method: used in a pipeline without injection point or without exposed section.
3. Many kinds of detecting frequency: 480Hz, 7.7KHz , 31KHz and 61KHz, which are four kinds of active frequency and 50Hz of passive frequency using in electric cable; The user may carry on the choice according to the different environment (need special detecting frequency please indicate specially in order contract).
4. Enhancement test efficiency by different localization pattern and function:
(1) peak value pattern: Determines the position through the maximum route signal.
(2) valley value pattern: Determines the position through the minimum route signal
(3) route direction detection: Direct-viewing, instructs the route rapidly the direction.
(4) insulation fault finding (FF): Detect and locate the insulate fault point of pipeline and cable .
(5) Stethoscope: find loading signal on the pipeline through stethoscope from the multitudinous pipelines.
5. Auxiliary functions:
(1) Automatic control receive gain: The automatic control receiver gain can keep the receiver to be at the optimized status and avoid manual operation.
(2) Sound function: The receiver reflects the detecting signal intuitively through the tonality changing.
(3) Check the detecting condition: When the transmitter in injection mode, first test the insulation resistance and the residual voltage of pipeline, then load the signal to a pipeline. When the value of the insulation resistance too small (almost in short-circuits) the transmitter will withdraw automatic from this mode, when the residual voltage is so large the transmitter will warn, the operator must stop to load signal and shut off the transmitter.
(4) Battery value testing: Real-time detection of battery, when the voltage lower than the protect value, the transmitter will warn and automatic shut-down.
(5) Power save: The machine will be off to save the power if the transmitter is not be operated after booting in 30 second, and if the receiver is not be operated after booting and no other keystrokes about 10 minutes.
Signals Transmitting Method:
1. Injection method:
Injection method is fit for the application that can find the electrical connection points on the goal pipeline and cable, such as optical cable outlet and the bolts of metal pipeline, etc.
2. Induction method:
Induction method is used in a pipeline without injection point or without exposed section.
3. Clamping Method:
Clamping method is used in a pipeline with the exposed section and easy to clamp.
Specification:
Transmitter: | ||||
Signal Frequency for Injection Method | 480Hz, 7.7KHz, 31KHz, 61KHz | |||
Signal Frequency for Induction Method | 31KHz, 61KHz | |||
Signal Frequency for Clamping Method | 31KHz | |||
Signal Frequency for Fault Finding | 480Hz | |||
Output Voltage | 0-400Vp-p adjust according to the insulation condition | |||
Output Wave Shape | sine wave | |||
Power Supply | 11.1VDC 4.4AH Li-battery | |||
Maximum Output Power | 10W | |||
Receiver: | ||||
Power Loss | <1W | |||
Power Supply | 11.1VDC 1.8AH Li-battery | |||
Max. Burial Depth for Detecting | 4.5 meters (normal condition) | |||
Tolerance of burial Depth for Detecting | ±0.05H ±5cm (“H” is pipeline burial depth) | |||
Tolerance of Route for Detecting | ≤5cm | |||
The Effective Length under Detecting Pipeline Route and Depth with Injection Method | ≥10Km (normal condition) | |||
The Effective Length under Detecting Pipeline Route and Depth with Induction method | ≥3Km (normal condition) | |||
The Effective Length under Detecting Pipeline Route and Depth with Clamping method | ≥6Km (normal condition) | |||
Insulated Fault Detecting | ≥2 M* | |||
Environmental: | ||||
Operating Temperature | -20℃~+50℃ | |||
Storage Temperature | -40℃~+70℃ | |||
Relative Humidity | 10%~90% | |||
Atmospheric Pressure | 86~106KPa | |||
Environmental Noise | ≤60dB | |||
Weight and Dimension: | ||||
Name | Weight (Kg) | External Dimensions (mm) | ||
Transmitter | 3.4 | 348×239×175 | ||
Receiver | 2.6 | 648×260×130 | ||
Entire Machine (Gross Weight) | 14 | 790×250×420 | ||
Optional Accessories: | ||||
Name | Weight (Kg) | External Dimensions (mm) | ||
Fault Finding Holder | 1.5 | 525×672×25 |
Remark: Normal condition means that without insulation fault and other interference in the measuring range as detecting the pipeline.
Accessories:
Item | Name | Quantity |
1 | Transmitter | 1pc |
2 | Receiver | 1pc |
3 | Carrying case | 1pc |
4 | User manual | 1pc |
5 | Charger | 2pcs |
6 | Earthing stick | 1pc |
7 | Signal output line | 1pc |
8 | Inductive clamp | 1pc |
9 | Stethoscope | 1pc |
10 | Certificate | 1pc |
Ordering Information:
Model | Name | Description |
CL1400 | Pipeline and Cable Locator | With inductive clamp and stethoscope |
CL1400A | Pipeline and Cable Locator | With inductive clamp, stethoscope and Fault Finding Holder |
CL1400B | Pipeline and Cable Locator | With inductive clamp, stethoscope and GPS |