NetApp FAS2500 Series FAS2552
Negotiable /Piece
Min.Order:1 Piece
Guangzhou Suenyuet Technology Ltd.
NetApp FAS2500 hybrid storage arrays deliver superior ROI, reduce your operational cost, and minimize risks for growth.
Whatever the size of your enterprise, you need powerful, flexible storage that manages growth while maximizing the long-term value of your IT investment. The NetApp FAS2500 series running clustered Data ONTAP simplifies storage operations and connection to the cloud. Its unified architecture supports a broader set of SAN and NAS workloads—with faster setup than any other entry-class hybrid array.
Get more from your investment. Leverage up to 20x more of the industry’s most efficient flash technology—accelerating workloads by up to 46%. Boost hard-disk utilization further with enhanced partitioning and storage efficiencies.
Reduce IT operational costs. Deploy a single unit or a complete cluster faster with System Setup. Automate storage management (provision, protect, monitor) with the click of a button.
Minimize risk and disruption. Start small to minimize upfront costs. Scale up to eight nodes—without disruption—as your data requirements grow. Connect to the cloud without vendor lock-in.
FAS2552 | ||
---|---|---|
Single Controller | Dual Controller | |
Max. Raw Capacity | 759TB | 759TB |
Internal Drives | 24 | 24 |
Supported Internal Drives | ||
Performance HDD | 600GB, 900GB, 1.2TB | |
Capacity HDD | N/A | |
SSD | 200GB, 400GB, 800GB,1.6TB | |
Self-encrypting Drives | 900GB at 10K RPM,800GB SSD AES-256, FIPS 140-2 compliant | |
Max. Drives (Internal + External) | 144 | 144 |
ECC Memory | 18GB | 36GB |
Controller Form Factor | 1 or 2 controllers in a single 4U chassis | |
Maximum Flash Pool | 16TB[1] | 16TB[1] |
NVMEM/NVRAM | 2GB | 4GB |
Onboard I/O: UTA 2 (8Gb FC/16Gb FC/FCoE/10GbE/1GbE[2]) | 4 [3] | 8 [3] |
Onboard I/O: 10G Base-T | N/A | N/A |
Onboard I/O: 6Gb SAS | 2 | 4 |
Onboard I/O: GbE | 2 | 4 |
Notes
[1] 16TB for Data ONTAP 8.3, 4TB for Data ONTAP 8.2 (cluster mode and 7-mode).
[2] 1GbE optical and copper SFP support starts with the release of Data ONTAP 8.3.1RC
[3] FAS2552 and FAS2554 onboard UTA2 ports can be configured as either 8Gb/16Gb FC port pair or 10GbE/1GbE port pair and mixed combinations.
[4] FAS2520 onboard ports are 10GBASE-T only that can autorange to 1GbE.
FAS2552 | |
---|---|
NAS/SAN Scale-out | 1–8 nodes (4 HA pairs) |
Maximum Drives | 576 |
Maximum Raw Capacity | 3.0PB |
Maximum Flash Pool | 64TB |
Maximum Memory | 144GB |
Cluster Interconnect | 10GbE |
FAS2554 | ||
---|---|---|
Thermal Rating | 1,218 BTU (typical) 1,737 BTU (worst case) | |
Weight | 55.4 lbs | |
Height | 3.35" (8.5 cm), fits into 2U space | |
Width | 19" IEC rack-compliant (17.6", 44.7 cm) | |
Depth (without cable management brackets) | 19" (48 cm) | |
Operating Temperature, Altitude, and Relative Humidity | 50°F to 104°F (10°C to 40°C); at ≤ 3,000m (at ≤ 10,000') elevation; 20% to 80% relative humidity, noncondensing | |
Nonoperating Temperature and Relative Humidity | -40°F to 158°F (-40°C to 70°C); at ≤ 12,192m (at ≤ 40,000') typical of unconditioned airplane cargo bay, 8% to 80% relative humidity, noncondensing, in original container | |
Operating Acoustic Noise | FAS2520:
| |
Compliance | RoHS-compliant (PDF) | |
Safety/Emissions/Immunity | Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, CU, BIS, BSMI, SONCAP, NRCS LOA (South Africa) Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI |
Relative goods:
FAS 2554, FAS 2552, FAS 2520
Our Service
Why to Choose SuenYuet?
* 100% New and Original CISCO Packing.
* Answer your enquiries, questions and emails in 24 hours.
* Flexible Payment terms ranged at different quantity.