RF Professional For CLINIC CO2 Fractional Laser Machine For Traumatic Scars K11 Remove Neoplasms
USD $9,000 - $18,000 /Set
Min.Order:1 Set
Shanghai Aomei Laser Technology Co., Ltd.
Fractional resurfacing is a new laser treatment modality that creates numerous microscopic thermal injury zones of controlled width, depth,and density that are surrounded by a reservoir of spared epidermal and dermal tissue,allowing for rapid repair of laser-induced thermal injury. This unique modality, if implemented with proper laser- delivery systems, enables high-energy treatments while minimizing risks.
2.This machine use the RF Tube manufacturerd by Coherent America,the frequency can reach more than5000HZ,the high speed can work more efficiecnt and effectively,it is very good for the ultra pulse incision for the precise surgey,no blood,the treatment area is very clear,andless down time.
CO2 Scanner Laser Machine
1. Principle of treatment
Fractional laser technology is a kind minimal invasive treatment between invasive and noninvasive,which is the latest and hottes skin care technology in USA, and it’s also the most often talked about by dermatology community for these two years in the world. It was first published in 2004 by laser medical expert of Harvard university,Dr. Rox Anderson, who based on the fractional photothermolysis theory.Then it is immediately recognized by experts all over the world and rapidly applied to clinical treatment. fractional photothermolysis theory is an extension of traditional selective Photothermolysis theory. It combines the advantages of invasive treatment and noninvasive treatment, so it is a kind of rapid treatment with prominent effects, little side effects and shorter period of recovery. Fractional laser treatment is by the means of punching every tiny holes in the skin by using laser, then arouse a series of biochemical reactions of skin to achieve skin tighting, skin rejuvention and pigmentation removal. Fractional laser treatment will only cover part of skin tissues, and the newsmall holesare not overlapped mutually, so part of normal skin will be retained and speed up to recover. Patient can return to normal life after 4-5 days.
2. Appilcation
1.Skin resurfacing(wrinkle removal)
2.Acne and acne scars
3.Pigmentation(age spot, sun spot, melasma)
4.Roughness(texture)
3. Advantage
1. Fast
2. Comfortable
3. Variable density and denth
4. One or two treatment
5. Single pass
6. No consumable costs
4. Technical Specification
Model | PC030-B(Ultra Pulse) |
Wavelength | 10600nm |
Mode Structure | TEM00 |
Max Power | 30W |
Peak Ppwer | 800W |
Laser Output Modes | Continuous, Single Pulse,Ultra Pulse |
Aiming Beam | 5mW Diode |
Controls | Touch Screen |
Display | Color LCD |
Cooling | Water Closed Cycle Cooling System |
Beam Delivery | 7Joints Articulates Arm |
Electrical | 230V 50Hz |
Warranty | 1 year |
5. Easy to Operate:
The scanner could be applicable in laser surgery, the doctor who operating with the scanner is not needed to have a complicate training course for operating steps. Instead, the doctor only need to select the figure of treatment, then easy to set up the most basic parameter and to do the treatment. The operation of scanner will be easy and humanized, so that the doctor could serve for each patient more intently.
6. The Scanner Technical Specification:
Spot Size | ≤0.2mm Min 0.1mm at the focus |
Interval Between 2 Spots | 100us-10ms(adjustable) |
Pulse Repetition | 1-1000Hz |
Treatment size | 20x20mm |
Net Weight | 0.7kg/1.5kg(adjustable) |
Size | 60x60x40mm |
Any requirement, pls feel free to let us know!
Amanda Zhang
Features:
1. Reduced thermal damage to surrounding tissues
2. Rapid healing and minimal downtime
3. Stimulate deeper collagen with high pulse energy
4. LCD display panel provides easy operation with the latest microprocessor technology
5. Adjustable scanning patterns and size
6. Adjustable intensity of pilot beam from zero to maximum
7. Adjustable pulse duration
8. Last treatment setting memorization
9. Automatic alarm system for operation and troubles
10. Covers all functions of conventional system
11. No consumable costs