Double laser orthogonal optical bench Winner2005A Ceramic materials particle size analysis instruments
USD $1 - $2 /Set
Min.Order:1 Set
Jinan Winner Particle Instruments Co., Ltd.
Stable test China topseller Winner 2000ZDE zirconium particle size analysis Instrument
HE-NE Laser ultrasonic dispersion Winner2000ZD Zirconia particle size Analysis instrument
30Years experience universal Winner2308C Charcoal Particle Size Analysis instrument
Stable test China topseller Winner 2000ZDE coke powder particle size analysis Instrument
Double laser orthogonal optical bench Winner2005A Ceramic materials particle size analysis instruments
Brief Introduction:
Winner2005 is intelligent full automatic laser particle size analyzer. It enables you understand materials well, such as painting,dyes, minerals power, calcium carbonate, kaolin, water-coal-slurry Photosensitive material,Medicine and Metal oxide etc. Industry.
Main Specifications:
Model Name | Winner2005A | Winner2005B | |||
Standard | ISO13320-1:1999,GB/T19077.1-2008,Q/0100JWN001-2013 | ||||
Size range | 0.01-780μm | 0.1-780μm | |||
Channels | 77 | 69 | |||
Accuracy | <1% (Deviation of D50 on national standard sample) | ||||
Repeatability | <1% (Deviation of D50 on national standard sample) | ||||
Laser | He-Ne Laser λ= 632.8nm, p>2mW Auxiliary Laser: semiconductor λ= 650nm,p>2mW | ||||
Wet dispersion | Ultrasonic | Frequency:40KHz Power:35W, Time: ≥1S | |||
Agitator | Revolutions Speed: 0-300RPM (Adjustable) | ||||
Circulation | Rated Flow:8L/min Rated Power:10W | ||||
Sample pool | Volume: 350mL | ||||
Operation mode | Manual and Full automatic | ||||
Optical alignment system | Full automatic optical path alignment system | ||||
Software function | Analysis mode | Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. | |||
Statistic Method | Volume Distribution, Quantity Distribution
| ||||
Statistic Comparison | Several Testing Results of samples Different batches of samples testing result, Samples before and after processing, Test result of samples in different time.
| ||||
User-defined Analysis | Figure out percentage according to the particle size Figure out particle size according to the percentage Figure out percentage according to the particle size range Meet demands of representation of particle test in different industries | ||||
Test Report | Word, Excel,Photo( Bmp), Text etc | ||||
Multi-language Support | Multi-language Support | ||||
Intelligent operation | Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor | ||||
Testing speed | <2min/time | ||||
Outer dimension | L85cm*W39cm*H45cm | ||||
Net weight | 40Kg |
Main Features:
1) Optical light system: Adopt orthogonal double laser beam patented technology, measure range expanded from 0.01-780μm.
2)Intelligent operation mode realize one key test, automatically draw water,ultrasonic dispersion, circulate and drain off water, so it not only could decrease workload, but also get better repeatability after remove human-factors errors.
3) Optical light Calibration System is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state..
4)Sample dispersion system: Full built-in setting mechanical stirring, ultrasonic dispersion, and circulation path in one, Big power-circulating pump and Optimization design of pipeline,effectively prevent large particle sediment.
5)Software support: Original Unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution.
Output parameters: D10/D50/D90, S/V,
Patent Technology:
Wooden box package, G.W.:60KG.
We would ship machine by DHL, FeDex, China express, by sea and by air.
Quality assurance
1. Strictly conforming to ISO9001-2000 quality management system,
2. Strict control from purchasing materials, process inspection to final test,
3. QC department to execute quality control regulations,
4.Only qualified components will be assembled and total equipment must be inspected completely before sale.
5, Machine will be processed preventing -shake test before delivery.
After sale service
1. We will send our technician to install instruments.( operation demo video CD will be offered also.)
2. Offer free-training service.
3. The quality assurance date is 2 years since finishing payment, Technology support in all a life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected).
5. We offer the components with favorable price and perdurable maintenance.
Jinan Winner Particle Instrument Co., Ltd. have been specialized in particle size analyzer for more than 20 years since that we take National science Project-particle size analyzer development in 1985.
High quality assurance is our task and also what we are doing now.
Pursue excellent quality,Provide first-class service,Look for agents from Domestic & Overseas!