Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

USD $1 - $2 /Set

Min.Order:1 Set

Supply Ability:
500 Set / Sets per Month
Port:
Qingdao/Hongkong
Payment Terms:
Credit Card PayPal

Quick Details View All >

Place of Origin:
Shandong, China
Brand Name:
Winner
Model Number:
2005

Jinan Winner Particle Instruments Co., Ltd.

Credit Member 4 years
Business Type: Manufacturer,Trading Company
Shandong China
Main Products: Laser particle size analyzer ,Spray laser particle size analyzer ,Image particle size analyzer ,Nanoparticles size analyzer ,Particle counter

Product Details

 

Product Description

 

 

Double laser orthogonal optical bench Winner2005A Mixture emulsion  particle size analysis instruments

 Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

Brief Introduction:    

 

Winner2005 is intelligent full automatic laser particle size analyzer. It enables you understand materials well, such as painting,dyes, minerals power, calcium carbonate, kaolin, water-coal-slurry  Photosensitive material,Medicine and Metal oxide etc. Industry.

 

 

Main Specifications:

 

Model Name

Winner2005A

Winner2005B

Standard

ISO13320-1:1999,GB/T19077.1-2008,Q/0100JWN001-2013

Size range

0.01-780μm

0.1-780μm

Channels

77

69

Accuracy

<1%   (Deviation of  D50 on national standard sample)

Repeatability

<1%   (Deviation of  D50 on national standard sample)

Laser

He-Ne Laser  λ= 632.8nm,  p>2mW

Auxiliary Laser: semiconductor λ= 650nm,p>2mW

Wet dispersion

Ultrasonic

Frequency:40KHz   Power:35W,   Time: ≥1S

Agitator

Revolutions Speed: 0-300RPM (Adjustable)

Circulation

Rated Flow:8L/min    Rated Power:10W

Sample pool

Volume: 350mL

Operation mode

Manual and Full automatic 

Optical alignment system

Full automatic optical path alignment system

Software function

Analysis mode

Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. 

Statistic Method

Volume Distribution, Quantity Distribution 

 

Statistic Comparison

Several Testing Results of samples

Different batches of samples testing result,

Samples before and after processing, 

Test result of samples in different time.

 

User-defined Analysis

Figure out percentage according to the particle size

Figure out particle size according to the percentage

Figure out percentage according to the particle size range

Meet demands of representation of particle test in different industries

Test Report

Word, Excel,Photo( Bmp), Text etc

Multi-language Support

Multi-language Support

Intelligent operation

 Automatically control water inflow, dispersion,test and analysis.Better Repeatability after remove human-factor

Testing speed

<2min/time

Outer dimension

L85cm*W39cm*H45cm

Net weight

40Kg

 

 

Main Features:

 

1) Optical light system: Adopt orthogonal double laser beam patented technology, measure range expanded from 0.01-780μm.      

 

2)Intelligent operation mode realize one key test, automatically draw water,ultrasonic dispersion, circulate and drain off water, so it not only could decrease workload, but also get better repeatability after remove human-factors errors.

 

3) Optical light Calibration System is composed of precise four phase hybrid stepper motor, Its inching precision is reach to micron level, so light path is always in a good state..

 

4)Sample dispersion system: Full built-in setting mechanical stirring, ultrasonic dispersion, and circulation path in one, Big power-circulating pump and Optimization design of pipeline,effectively prevent large particle sediment. 

 

5)Software support: Original Unconstrained free fitting technology make particle analysis not be restricted by any functions, truly reflect particles distribution.

 

Output parameters: D10/D50/D90, S/V, 

 

 

Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

 

 

 

Certifications

  

   Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

 

Patent Technology:

 

  1. optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
  2. Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
  3. Mie scattering principle application patent No.- ZL 2013 2 0812021.4.
  4. Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0
  5. Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2

 

 

 

 

Packaging & Shipping

 Wooden box package, G.W.:60KG.

We would ship machine by DHL, FeDex, China express, by sea and by air. 

 Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

 

Our Services

 

Quality assurance 


1. Strictly conforming to ISO9001-2000 quality management system,  
2. Strict control from purchasing materials, process inspection to final test, 
3. QC department to execute quality control regulations,
4.Only qualified components will be assembled and total equipment must be inspected completely before sale.

5, Machine will be processed preventing -shake test before delivery.

 

Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

After sale service 


1. We will send our technician to install instruments.( operation demo video CD will be offered also.) 
2. Offer free-training service. 
3. The quality assurance date is 2 years since finishing payment, Technology support in all a life. And after that, we will collect the cost if provide repair accessories.
4. Maintenance for equipment failure caused by improper handling (appropriate cost will be collected). 
5. We offer the components with favorable price and perdurable maintenance. 

 

 

Why choose us

 Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

Company Information

 

Jinan Winner Particle Instrument Co., Ltd. have been specialized in particle size analyzer for more than 20 years since that we take National science Project-particle size analyzer development in 1985.

 

High quality assurance is our task and also what we are doing now.  

Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments 

 

 

Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

Contact Cathy

Pursue excellent quality,Provide first-class service,Look for agents from Domestic & Overseas!

 

Double laser orthogonal optical bench Winner2005A Mixture emulsion particle size analysis instruments

 

 

Contact Supplier

Ms. Cathy Feng Overseas Manager Chat Now
Telephone
86-531-88873319
Mobile
0086-13698611832
Fax
86-531-88873392
Address
Building F Unite two, North Area, University & Science Park, NO75 Shunhua Road High-tech Zone, Jinan city. Shandong

You May Like

New Products

Find Similar Products By Category

Measurement & Analysis Instruments > Analyzers > Other Analysis Instruments
Categories
Hi~