LHS Fire Tube 144 KW Hot Water Boiler For Heating
USD $300 - $350 /Set
Min.Order:1 Set
Qingdao East Power Industry Equipment Co., Ltd.
LHS Fire Tube 144 KW Hot Water Boiler For Heating
A: Features
1) The boilers have 2 functions
- Supply Heating for house, apartment. It connect with radiator/floor heating pipe to combine a system to working.
- Shower Hot Water for house, apartment.
These 2 function work separately and work in different temperature range.
2) Heating function has 2 models to select,
- they can change each other easily through "Model changer" on the boiler bottom.
Floor heating: 30~55°C;
Radiator: 30~80°C,
it is free to set up the temperature.
3) Domestic hot water is prior.
- When hot water faucet is opened the gas boiler convert from Heating mode to Domestic hot water mode.
Until user close water faucet the boiler will continue to supply heating.
Above action is controlled automatically by the Microcomputer inside boiler.
4) Anti-freeze protection.
- When the room temperature drop to below 7°C the circulating water pump operate and modulating gas valve allows to warm the water to 30°C then boiler stop working.
Above acton also be controlled by the Microcomputer inside boiler.
5) Pressure release safety valve.
- When the Heating system pressure reach to 3 bar the safety valve will be opened to relief the high pressure automatically.
6) Balance type smoke tube, means Air inlet pipe and Exhaust pipe combined into a concentric circles.
B:Boiler parameter
Small Size Oil (gas)-fired Warm Boiler Parameter | |||||||||
Itemmodel | CLHS0.06-85/60-Q.Y | CLHS0.08-85/60-Q.Y | CLHS0.12-85/60-Q.Y | CLHS0.18-85/60-Q.Y | CLHS0.23-85/60-Q.Y | CLHS0.35-85/60-Q.Y | CLHS0.48-85/60-Q.Y | CLHS0.23-0.4/95/70-Q.Y | |
rated heat capacity kw | 60 | 80 | 120 | 180 | 230 | 350 | 480 | 230 | |
rated heat power Kcal/h | 5x104 | 7x104 | 10x104 | 15x104 | 20x104 | 30x104 | 40x104 | 20x104 | |
rated working pressure MPa | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.4 | |
saturated steam temperature °C | 85/60 | 85/60 | 85/60 | 85/60 | 85/60 | 85/60 | 85/60 | 95/70 | |
design heat efficiency % | >89 | >89 | >89 | >89 | >89 | >89 | >89 | >89 | |
heating area m² | 1.85 | 2.25 | 3.25 | 6.16 | 6.9 | 10.8 | 14.5 | 7.2 | |
boiler water capacity L | 126 | 168 | 222 | 361 | 371 | 783.8 | 818.9 | 571 | |
flue diameter mm | 160 | 160 | 160 | 250 | 250 | 300 | 300 | 250 | |
feed water diameter DN | 40 | 50 | 50 | 65 | 65 | 65 | 65 | 50 | |
blowdown tube diameter DN | 50 | 40 | 50 | 50 | 50 | 50 | 50 | 40 | |
fuel consumption | light oil kg/h | 5.7 | 7.9 | 11.5 | 17.0 | 22.6 | 33.5 | 46.0 | 22.5 |
natural gas Nm3/h | 6.7 | 9.3 | 13.5 | 20.0 | 27.0 | 40.3 | 53.8 | 26.0 | |
liquid gas Nm3/h | 2.6 | 3.6 | 5.2 | 7.8 | 10.3 | 15.7 | 21.2 | 10.3 | |
coal gas Nm³/h | 15.0 | 20.8 | 30.2 | 44.9 | 60.5 | 90.7 | 121.0 | 59.0 | |
transportation weight kg | 200 | 260 | 300 | 450 | 520 | 850 | 920 | 760 | |
outlook size | L mm | 640 | 700 | 700 | 900 | 900 | 1200 | 1200 | 1000 |
W mm | 580 | 660 | 660 | 850 | 850 | 1150 | 1150 | 950 | |
H mm | 1280 | 1300 | 1600 | 1750 | 1850 | 1950 | 2150 | 1970 | |
Notes:This form only for your reference,if any changed,please refer to Ex-factory technical documents. |