mppt solar charge controller
USD $1 - $300 /Piece
Min.Order:20 Pieces
Shenzhen South Sunlight Solar Technology Co., Ltd.
model | 30A | 40A | 50A | 60A | 30A | 40A | 50A | 60A | |||||
Rated voltage | 24V | 48V | |||||||||||
Component power | 720 | 960 | 1200 | 1440 | 1500 | 2000 | 2500 | 2800 | |||||
charging | charging (A) | 30 | 40 | 50 | 60 | 30 | 40 | 50 | 60 | ||||
Even charge protection | 28.8V±1% | 57.6V±1% | |||||||||||
floating Charge | 27.6V±1% | 55.2V±1% | |||||||||||
Even charge recover | 26.4V±1% | 42.8V±1% | |||||||||||
Temperature Compensation | -48mV/°C | ||||||||||||
Over Discharge | Shut off | 21.8V±1% | 43.6V±1% | ||||||||||
Resume | 24.6V±1% | 49.2V±1% | |||||||||||
Over voltage | Shut off | 32.0V±1% | 64.0V±1% | ||||||||||
Resume | 30.0V±1% | 60.0V±1% | |||||||||||
No-load Current | ≤0.1A | ||||||||||||
Voltage drop | ≤0.5V | ||||||||||||
Control mode | Maximum power point tracking-MPPT (charging efficiency higher 30% than the ordinary type PWM)
| ||||||||||||
Display | LCD | ||||||||||||
Show parameters | voltage,charge current,battery volumetric | ||||||||||||
Protected type | Lightning protection, solar cells, anti-anti-charge protection, battery open-circuit protection, battery reversal protection, | ||||||||||||
Heat emanation way | radiator | ||||||||||||
Working Temperature | -35°C~+55°C | ||||||||||||
Height | ≤5500m(2000m above the need to reduce power use) | ||||||||||||
Environment humidity | 0~90%,No condensation |
mppt solar charge controller
1.LCD showing system critical parameters
2.PWM charging control
3.CE certification
* Solar prevent reverse charge, at night or the light is bad, the battery voltage may be higher than the solar array voltage. The controller can prevent the generation of solar cells reverse battery charge
* Reverse battery protection, Reversed when the batteries have a huge transient current of the circuit fuse in the fuse will automatically make the battery circuit is disconnected, so as to effectively protect the battery and the device.
* Battery open circuit protection, Long-term use, the battery open-circuit may occur, or poor contact. The controller in the battery open-circuit protection device itself will not be damaged.
* Overload protection, the controller will automatically cut off the circuit.
Mppt solar charge controller safety and protection:
Note: The lightning protection equipment is necessary to protect the last one for the lightning-prone areas; we need a dedicated SPD composed of multi-stage lightning protection system. If you have this requirement, the need to increase the distribution system and the corresponding costs required to indicate when ordering.