1. Primary network protocol:BACnet MS/TP
2. Sub-network protocol: Modbus RTU
3. read/write access of up to 250 data-points.

Key Specification

 
   
PILOT  Point Expansion unit,  type HPE - BNMOD,  is for integration of Modbus RTU slave devices in to BACnet MS/TP networks. Multiple Modbus RTU devices of any mix may be connected to the HPE-BNMOD for read/write access of up to 250 data-points.
 
All points may be individually scaled and multiple points representing Modbus registers which use multiple Words may be combined so that only one Object Instance representing the scaled multiple Word register value needs to be read up by the BMS.

Application Data 

Primary network protocol:BACnet MS/TP
Sub-network protocol: Modbus RTU 

----------------------------------------------------
Administration points:
Point 1- Diagnostic counter reset

Point 2- BACnet comms error count
 
Point 3- Modbus comms error count
 
Point 1000- BACnet node
 
Point 1001- BACnet baud rate

 Point 1002- Modbus baud rate / config.

DI- BACnet global Device Instance
 
MM- Max Master

SV- System Vendor ID 

------------------------------------------------------------------------
Modbus RTU data points:
250 total, point 4...253 

------------------------------------------------------------------------
Supported Modbus RTU functions:
01- Read (write) Coil status 

02- Read Discrete Input

03- Read (write) Holding Register

04- Read Input Register 

------------------------------------------------------------------------
Comm speed selection, BACnet MS/TP:2400, 4800, 9600 (default), 19200, 38400, 76800

Comm speed selection, Modbus subnet:2400, 4800, 9600 (default), 19200

Modbus subnet comm configuration:7/8 data bits ¨C Odd/Even/No parity ¨C 1/2 stop bits
(default ¨C 8N1) 
 

Payment TermsT/T,  L/C
Minimum Order8
Lead Time / Delivery Time5 Day(s)
Sample AvailableYES
FOB PortGaoxiong,Shenzhen,Zhuhai
Target Market(s)Africa,  Eastern Europe,  Hong Kong/ Macao/ Taiwan,  Japan & Korea,  Latin America,  Mainland China,  Middle East,  North America,  Northern Europe,  Oceania,  South Asia,  Southeast Asia,  Western Europe

 

Modbus RTU to BACnet - Network gateway

Contact Supplier

Mr. Jackey Zhou Director Chat Now
Telephone
86-756-3629673,3629699
Mobile
008613928018523
Fax
86-756-3629600,3629700
Address
No.15, Keji 6 Road, Chuangxin Haian, Tangjia Hi-tech Zone, Zhuhai, Guangdong Zhuhai,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Electronic & Instrument Enclosures
Categories
Hi~