Specifications
1.LED screen display ups2.True on-line double conversion technology with advanced microprocessor control
3.110V/220V 1-6KVA
Online ups LCD rack mount BS Series adopts to servers, data centers, critical network devices, sensitive electronic equipment, Telecom and so on.
Key Features
- True on-line double conversion technology with advanced microprocessor control
- Wide input voltage range
- Zero transfer time
- Protection against all type of power problems
- Self test while start of the UPS
- Site wiring fault warning
- On-battery power-on function
- Smart RS232 communication interface
- Intelligent slot available
- Sealed lead-acid, maintenance free battery
Technical Specifications
Product Series | Rack Mount 1~6kVA | ||||
Model | BS1KR | BS2KR | BS3KR | BS6KR | |
Rated Power | VA/W | 1kVA/0.7kW | 2kVA/1.4kW | 3kVA/2.1kW | 6kVA/4.2kW |
Input | Nominal Voltage | 110V/220VAC | |||
Voltage Range | 60~138 Vac 115 ~ 300VAC | 176 ~ 276VAC | |||
Frequency Range | 46 ~ 54Hz(default), user adjustable within 40~60Hz | 46 ~ 54Hz | |||
Power Factor | 0.97 | 0.98 | |||
Connection | IEC320-10A inlet | IEC320-16A inlet | Terminal Block | ||
Output | Voltage | 110V/220VAC ± 2% | 110V/220VAC ± 1% | ||
Frequency | 46~54Hz or 50Hz ± 0.2Hz (Line mode) 50Hz ± 0.2Hz ( Battery mode) | 46~54Hz (Line mode) 50Hz ± 0.05Hz ( Battery mode) | |||
Waveform | Sine Wave | ||||
Overload Capability | 108%~150% for 30 sec., ³150% for 300 ms | 105%~130% for 10 min., ³130% for 1 min. | |||
Current Crest Ratio | 3:1 | ||||
Bypass | Automatic Transfer | on overload and UPS failure | |||
Before UPS Power-on | Default NO, user adjustable to YES | Yes | |||
Output Connections | IEC320 -10A * 4 | IEC320-10A * 4 | IEC320-10A and Terminal Block | IEC320-10A * 4 and Terminal Block | |
Transfer Time | 0 ms; less than 4 ms from inverter to bypass and vice versa | Zero | |||
LED indicators | Status | Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault | |||
Audible Alarm | Bypass, On battery mode, Battery low, Overload, Fault | ||||
Communications | RS-232 Serial Interface | ||||
Intelligent Slot; OPTIONS: WEBPOWER SNMP/WEB card, AS400 card or WinPower CMC) | |||||
Network Surge Protection | RJ45 I/O port available for network or Fax/Modem | ||||
Environmental | Operating Temperature | 0 ~ 40°C | |||
Operating Humidity | 20 ~ 90% non-condensing | ||||
Main Unit | Net Weight (Kg) | 15.0 | 9.6 | 10.0 | 18.3 |
Dimensions (W x D x H) mm | 482 x 420 x 88 (2U) | 482.6 x 600 x 130 (3U) | |||
Battery Pack | Type | Internal Batteries | External Battery Pack | ||
Nominal DC Voltage | 36VDC | 96VDC | 240VDC | ||
Backup Time (Full load) | 5 min | 9 min (with 1 BP) | 5 min (with 1 BP) | 7 min (with 1 BP) | |
Net Weight (Kg) | -- | 26.0 | 64.2 | ||
Dimensions (W x D x H) mm | -- | 482 x 420 x 88 (2U) | 482.6 x 600 x 130 (3U) |