10KVA to 200KVA three phase low frequency ups for industrial use
1, Features
High reliability
True on-line static bypass technology, to provide strong overload and fault protection device.
Internal manual maintenance bypass, further improve the reliability of continuous operation of the load.
Network management humanity
Communicate with PC by RS232.
Use SNMP adapter, UPS can realize remote network management function.
Parallel redundancy
Can parallel 8 units UPS;
Parallel UPS units can share a battery pack;
Non-fixed master/slave parallel
2,Product specification:
MODEL-HT | 10KS | 20KS | 30KS | 40KS | 60KS | 80KS | 100KS | 120KS | 160KS | 200KS |
RATED POWER | 10KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA |
(VA/W) | 8KW | 16KW | 24KW | 32KW | 48KW | 64KW | 80KW | 96KW | 128KW | 160KW |
INPUT | ||||||||||
INPUT VOLTAGE | 380VAC(3 phases) or 190VAC(3 phase) | |||||||||
VOLTAGE RANGE | 304-456VAC or 152-228VAC | |||||||||
FREQUENCY | 50/60Hz±5% | |||||||||
Power Factor | >0.97 | |||||||||
Max. input current | 18A | 37A | 55A | 72A | 108A | 130A | 160A | 190A | 245A | 310A |
OUTPUT | ||||||||||
Voltage | 380VAC/190VAC±1% | |||||||||
Frequency | Sync to input(line mode),50Hz or 60Hz±0.05 | |||||||||
Waveform Type | pure sinewave | |||||||||
Power Factor | 0.8 | |||||||||
THD | <3% with linear load | |||||||||
Overload Capability | 110% for 300mins /125% for 10mins /150% for 1min then transfer to bypass & alarm | |||||||||
Current Crest Ratio | 3:1(max) | |||||||||
overall efficiency | >90% | |||||||||
Transfer Time | ||||||||||
From inverter to battery | 0ms | |||||||||
Bypass | ||||||||||
Voltage | 380VAC | |||||||||
bypass voltage range | ±10%,±15%,±20% adjustable | |||||||||
Battery | ||||||||||
Voltage | 384VDC | 432VDC | 480VDC | |||||||
Recharge Time | 8~10 hrs to 90% of capacity after full load discharge | |||||||||
LED /LCD Indications | ||||||||||
LED | Battery level,utility power,inverter,bypass,Fault, overload | |||||||||
LCD | Input/output voltage,Frequency,battery voltage,load percent,Tempreature | |||||||||
Communications | ||||||||||
interface | RS232 SNMP(optional) | |||||||||
Intelligent Slot | Dry Contact/EPO/SNMP Card (optional) | |||||||||
Working conditon | ||||||||||
Temperature | 0~40°C | |||||||||
Humidity | 0~95%°C non-condensing | |||||||||
Storage tempreature | -25°C~55%°C | |||||||||
Acoustic Noise | <55dB | <60dB | <65dB | <70dB | ||||||
Weight | ||||||||||
N.W(Kg) | 223 | 260 | 336 | 351 | 497 | 556 | 756 | 901 | 1300 | 1350 |
G.W(Kg) | 280 | 317 | 393 | 408 | 574 | 633 | 856 | 1001 | 1400 | 1450 |
W×D×H mm | 555*725*1220 | 800*745*1400 | 1070*745*1400 | 1420*745*1810 | ||||||
S: long backup | ||||||||||