6~20KVA Hot High Frequency Online UPS
Negotiable /Piece
Min.Order:30 Pieces
Shenzhen Santek Power Co., Limited
Pure sine wave 6kva online ups , pure sine wave inverter ups
High quality ups inverter ,ups system,single phase pure sine wave ups 6kva
High quality ups inverter ,10kva ups,single phase pure sine wave ups battery 12v 26ah Quality Choice
High quality ups inverter ,single phase pure sine wave 10kva ups
Hot High Frequency Online UPS
Application:
Computer center, network center, communication system, automation control system or other critical systems
Features:
1. Double conversion online technology
2. MCU intelligent control
3. Wide input voltage range
4. LCD and LED user interface
5. Optional 110/230 output voltage
6. Cold start
7. Short circuit and overload protection
8. Self-test when UPS start
9. Auto restart after utility power restore when UPS shutdown due to battery low
12. Over temperature and over voltage protection
10. Optional extension battery pack
11. EMI/RFI noise filter
12. Smart RS232 communication with monitoring software
13. Optional SNMP card slot
Model | 6KN/6KS | 10KN/10KS | 3P10KS | 3P15KS | 3P20KS |
Power Capacity (VA/W) | 6KVA/4.2KW | 10KVA/7KW | 10KVA/7KW | 15KVA/10.5KW | 20KVA/14KW |
Input | |||||
Rated Voltage | 220V | ||||
Voltage Range | 176~276VAC | 304~478VAC | |||
Phase | Single | 3 phase(4 wires+ ground) | |||
Power Factor | 0.98 | 0.95 | |||
Connection | Hardwired | ||||
Output | |||||
Voltage | 220VAC±1% | ||||
Frequency Range | The same as utility frequency(Line mode), 60Hz/50Hz±0.2Hz(Battery mode) | ||||
Waveform | Pure sine wave | ||||
Power Factor | 0.7 | ||||
Voltage Distortion | <2% under liner load | ||||
Current Crest Ratio | 3:1Max | ||||
Overload Capacity | Line mode:105%<Load<130% for 10mins, Load>130% for 300ms, then transfer to bypass alarm. Battery mode:105%<Load<150% for 30s & load>150% for 300ms, then turn off output & alarm. | ||||
Battery | |||||
Type | Sealed Lead-Acid Maintenance free battery | ||||
Back-up time | 5min | N/A | |||
Recharge Time | 8hrs to 90% of capacity after full load discharge | ||||
Transfer Time | 0ms | ||||
Maintenance Bypass Switch | Yes | ||||
LED/LCD Indicators | |||||
Status | Load Lever/Battery lever,Battery,Utility Power,Inverter,Bypass, Overload,Fault. | ||||
Audible Alarm | |||||
Condition | Bypass,Battery mode,Battery low,Overload, Fault | ||||
Bypass | Alarm beeps every 2 minutes | ||||
Battery discharge | Alarm beeps every 4 seconds; Every second if battery low | ||||
Overload | Alarm beeps twice for every second | ||||
Fault | Alarm beeps continuously | ||||
Acoustic Noise | |||||
At 1 meter distance | <55dBA | <60dBA | |||
Communications | |||||
DB-9 Port | RS232 Serial Interface | ||||
Intelligent Slot | Options:Webpower,AS400 or Winpower CMC | ||||
Environmental | |||||
Operating Temperature | 0~40°C | ||||
Operating Humidity | 20~90% non-condensing | ||||
Net Weight(kg) | 90/46 | 93/38 | 45 | 55 | 55 |
Dimensions(W*D*H)mm | 260*570*717 |