WINSUN MQ-2 12V smoke time delay relay module MQ-2 smoke alarm liquefied gas alarm
USD $0.01 - $1,000 /Piece
Min.Order:1 Piece
Shenzhen Winsun Components Co., Limited
The MQ-2 smoke delay module requires a supply voltage of One2V
Product features:
With 1 MCU control, other functions can be customized;
2 to provide a variety of power input connection, to meet a variety of different needs;
3 with anti - power supply connected to anti - protection diodes, effective protection of products;
4 with a high current voltage regulator, to provide adequate power supply;
5, the use of high performance timing CPU design, double PCB board;
6, there is a power indicator (red LED) and switch trigger timing instructions (green LED);
7, the output can be connected to AC 10A 30V or DC 10A 250V load;
9, this module forsmoketouchWhen the hair.smokeAt a certain concentrationtime(the green LED light sensor moduleA),Instant start timing module is closed., green LED light time delay relay, relay, time end, green LED, release relay returned to normally closed end.(such as a direct trigger endSmoke signalLED (green lightA)The relay is always connected,Smoke signal(green LEDOut)After disconnection, start time, delay time to relay off);
11, such as when the triggering end time, continue to receivesmokeThis module will always delay signal, down relay does not disconnect and flash, until the stop trigger, will stop the clock;
12, timing potentiometer adjustment time,The product design for 1-180 seconds adjustable, can also be customized time range;
13, the time error of 5%
Product application:
1, with other kinds of sensors and relay module, can do all kinds of delay switch, directly with AC 220V products;
2, then methane / gas / combustible gas sensor can do all kinds of alarm delay trigger.
Electrical parameters:
Voltage: voltage 12V
Current: greater than or equal to 100mA
Load: 10A 250V AC or 10A 30V DC
Time time:1-180 seconds can be adjusted, can also be customized time range.
12V delay switch wiring instructions:
Delay time adjusting potentiometer:
Time is adjustable,Reverse timeIncrease the time needle,ShunThe needle to reduce the time,1-180 seconds adjustable, can also be customized time range
Time delay switch12V alarm control wiring method:
Time delay switchMethod for controlling connection of alternating current:
The relay output terminal pin is stated as follows:
Relay module control AC equipment wiring diagram:
Relay module control DC equipment wiring diagram: