Three Phase 40KVA Online UPS
USD $50 - $2,000 /Piece
Min.Order:1 Piece
Shenzhen Goter Power Technology Co., Ltd.
1. Product presentation:
HR9330 series of three in single out high-frequency intelligent online UPS is designed for high-reliability and high availability requirements of data center and computer network. The products adopt digital control technology to implement parallel expansion and parallel redundant features which will provide users with flexibility and higher security of power supply planning. This series product is from 6 KVA to 20KVA, the inputs can be single or three phases. UPS will automatically adapt the input voltage.
HR9330 series uses double-conversion architecture of pure line, which is the best architecture and the most effective solution to all power problems. This architecture is capable of effectively blocking the impact of abnormal power to the load, while maintaining the stability and reliability of the output power to ensure running safely with load.
2. Technical characteristics:
High-reliability design concept
All-digital controlled technology
Excellent performance
Comprehensive and reliable protection measures
Human-based information processing technology
Advanced digital control technology
3. Technical data:
Input voltage | Three phases 380VAC±20% Or single phase 220VAC±25% | Three phases 380VAC±20% |
Input frequency | 50(60) Hz ±5% adaptive | |
Frequency tracking rate | 1Hz/s | |
Power factor | >0.98( full load) | |
Output voltage | Single phase 220VAC | |
Output frequency | 50(60) Hz | |
Voltage stability | ±1% | |
Frequency stability | ±0.5% (mains power failure) | |
Waveform | SPWM sine wave | |
Distortion | <3% (linear load) | |
Transient response | Voltage change ≤4%(100% load on or take off) | |
Frequency of device | >90% | |
Switch time | 0ms: switch between mains modes and bypass modes <1ms:switch between mains modes and bypass modes | |
Mains power failure | Buzzer sounds for each 4s. | |
Overload | Overload indicator is lighting, buzzer is sounding. | |
Over temperature | UPS inner temperature >85°C, automatically switch to bypass. | |
Output short circuit | Limit current, automatically turn off, miniature circuit breaker protection | |
UPS failure | Automatically switch to bypass, mains power supply. | |
LCD screen | Display UPS running status, input/ output voltage, input/output frequency, output power(%)l inverter temperature; set up UPS parameter menu; failure code and history record etc. | |
Communication interface | RS232 interface, can inner build SNMP card, AS400 card | |
Environment temp. | 0~40°C | |
Environment humidity | 20~90% no condensation | |
Elevation | Less than 1000m, (when the elevation increases 500m, UPS output will reduce 5%) | |
Noise | <58dB (1m to cabinet) |
4. Model:
Models | Capacity | Dimension L*W*H (mm) | Weight |
HR9306 | 6KVA | 260×570×700 | 35 |
HR9310 | 10KVA | 38 | |
HR9315 | 15KVA | 300×580×800 | 55 |
HR9320 | 20KVA | 58 |