variable-frequency power source
USD $100 - $999 /Piece
Min.Order:1 Piece
Shenzhen Goter Power Technology Co., Ltd.
MH/BEST6500/TY Program-controlled variable frequency power supply 200KVA
PWM /GTP/ MH /HYProgram-controlled variable frequency power supply 50KVA
TY BEST6500 Program-controlled variable frequency power supply 100KVA
GTP/MH/BEST Program-controlled variable frequency power supply 10KVA
TY/BEST610 Program-controlled variable frequency power supply 100KVA
GTP Program-controlled variable frequency power supply picture
Technical characteristic:
1.High-precision, stable frequency and voltage with knob can quickly adjust the voltage and frequency.
2.High precision, screen digital display: frequency, voltage, current, power, power factor.
3.Quick response for status, regulating voltage response for 100% load/ unload in 2ms.
4.Output frequency: 50Hz, 60Hz, 47 ~ 63Hz (can be a special custom-made to the 35-400Hz) 100Hz (optional), 200Hz (optional), 400Hz, load frequency stability of ± 0.1%.
1. Output voltage: 0 ~ 300V (can be specially customized to 1000V), can simulate the world voltage load regulation accuracy of ± 0.5% (resistive load).
2. with overvoltage, overcurrent, overload, over temperature, such as multiple protection and alarm functions
Voltage filter |
DC/AC inverter |
AC/DC Rectifier filter
|
Input no fuse switch |
Output no fuse switch |
Mains power inpout 50/60HZ |
Quartz oscillator
|
Sine wave Generator |
Feedback circuit
|
Over current detection |
Output current display |
Output voltage display |
Output frequyency display |
Over Temperaturedetection
|
Over voltage detection |
Fuse power-off circuit to detect
|
Output to load |
Techinical data:
(GTP)Models MoMommmmModelMOdels | 6103 | 6105 | 6110 | 6120 | 6130 | 6150 | 6160 | 61100 | 61150 | 61200 | ||||||||||
Capacity(KVA)Capacity | 3 | 5 | 10 | 20 | 30 | 50 | 60 | 100 | 150 | 200 | ||||||||||
Circuit method | IGBT/SPWM method |
| ||||||||||||||||||
AC input | 1Φ2W220V±10% 50Hz/60Hz | 3Φ4W 380V±10% 50Hz/60Hz |
| |||||||||||||||||
AC output | Phases | single phases |
| |||||||||||||||||
V | Low voltag | 0-150V |
| |||||||||||||||||
High voltage | 0-300V |
| ||||||||||||||||||
Frequency | 47 Hz -63Hz,50 Hz,60 Hz,400 Hz |
| ||||||||||||||||||
Max A | A Low voltage | 27.0 | 45.0 | 90 | 180 | 270 | 450 | 540 | 900 | 1350 | 1800 | |||||||||
A High voltage | 13.5 | 22.5 | 45 | 90 | 135 | 225 | 270 | 450 | 675 | 900 | ||||||||||
Frequency stability | ≤±0.1% |
| ||||||||||||||||||
Load regulation | ≤±0.5% |
| ||||||||||||||||||
Waveform distortion | ≤1%( resistive load under test) |
| ||||||||||||||||||
Response time | ≤2ms |
| ||||||||||||||||||
Indicaor/resulution | Frequency | 4 digital resolution 0.1Hz |
| |||||||||||||||||
Votlage | 4 valid digital value resolution 0.1V |
| ||||||||||||||||||
Current | 4 valid digital value resolution 0.1A |
| ||||||||||||||||||
Power | 4 valid digital value resolution 0.1W |
| ||||||||||||||||||
Power factor | 4 digital resolution 0.001 |
| ||||||||||||||||||
Protection device | Over voltage protection, overload protection, over current protection,, over heating, short circuit protection and alarm. |
| ||||||||||||||||||
Cooling method | Forced fan cooling |
| ||||||||||||||||||
safety standard | Insulation resisitance | 500VDC/200MΩ |
| |||||||||||||||||
Voltage resistance insulation | 1800VAC/5mA/1min |
| ||||||||||||||||||
operation environment | Temperature 0°C-45°C, relative humidity 0-90%(no condensation) |
| ||||||||||||||||||
Models
Models | (KVA)Capacity |
Dimension (mm)W*L*H | (kg)Weight |
GTP6103 | 3 | 420*520*600 | 70 |
GTP6105 | 5 | 85 | |
GTP6110 | 10 | 900*450*710 | 180 |
GTP6120 | 20 | 1100*600*820 | 300 |
GTP6130 | 30 | 315 | |
GTP6150 | 50 | 1200*800*1020 | 490 |
GTP6160 | 60 | 600 | |
GTP61100 | 100 | 1500*800*1020 | 850 |
GTP61150 | 150 | 1800*800*1020 | 1200 |
GTP61200 | 200 | 1800 |