ANTI WRINKLE RF MACHINE WITH MASKS LED
USD $10 - $300 /Piece
Min.Order:1 Piece
Guangzhou Jimy Facial & Hair Beauty Products Co., Ltd.
ANTI WRINKLE RF MACHINE WITH MASKS LED
1. Working theory:
This "V" face instrument adopts the modern aesthetic idea of v-shape, which is designed with a new combination technology. Combined with the 5MHZ bipolar & four polar RF and 650nm near infrared light technologies,the energy work on the deep tissue to dissolve the fatness strongly. Meanwhile it accelerates the metabolism, which helps the excretion for the dissolved fatness, to get the good effect of face sliming and sculpture.
2.Machine structure
3. CONTROL PANEL
1,TIME 2,INTENSITY 3,MODE 4,ON/ OFF 5,V-01 for Bi-polar RF probe 6,V-02 Four-polar RF probe 7,V-03 LED mask |
Notes: The control panel is intelligent touch screen; only finger light touch is ok.
4. Technical Parameter:
Voltage: 220/110V
Frequency: 50/60Hz
Power: 110W
Energy Level: 1- 9 Levels
RF Frequency: 5 MHz.
5. Introduction of operating steps
a. Install the spare parts to right position.
b. Insert power plug.Open Power button at back of the machine,
c. Adjust Time (MIN and MAX to adjust time, it will start from 30 minutes, you can adjust it by MIN from 30-1 minutes or MAX from 30-99 minutes) By pressing MIN or MAX to add or minus 1 minutes.(The total treatment time we will suggest 45 minutes)
Intensity: Adjust from 1-9 (Usually we suggest to adju pic 2 st it by 3-5)
Mode: V-01 for Bi-polar RF, V-02 for Four Polar RF and V-03 for LED mask
It will start from V-01, then press the button you can choose the mode V-02 then V-0
ON/ OFF: to ON and OFF the machine
d. After TIME, INTENSITY AND MODE adjustment, please press ON/ OFF to start operating.
e. During operating, we can press INTENSITY to adjust ratio of intensity
6. Fittings
Bi-polar RF probe | 1 pc | Four polar RF probe | 1 pc |
LED Mask | 1 pc | Uniform light membrane | 1 pc |
Straps for LED mask | 1 pc | Power plug | 1 pc |
7. Spare part function and usage:
First Step: V-01 Bi-polar RF (20 Minutes)
Function:
5MHZ high frequency Bipolar RF , the current flows only through the tissue which is between the two electrodes on the handpiece, to penetrate deep into the skin and affect the deeper dermis and subcutaneous layers, causing tightening and improvements to the underlying tissue structure, but with little change in skin texture or fine lines and wrinkling.
n Usage:
1) Before the operation, both the customers and the beauticians should remove all the metal decorations.
2) The customer's hair root part must be protected with gel or towel during the facial treatment, to avoid the static friction between the probe and the hair, which may cause the hair burn.
3) It is advised to use products with higher oil to moist the skin.
4) During the operation, the RF probe must touch the skin firstly, then move the probe around and adjust the energy. The Energy should be adjusted slowly from low to high level until the customer feels comfortable.
Attention:
1) The headpiece can not leave the customer's skin, and can not stay in the same position. It must be moved around on the face during the whole operation process.
2) The headpiece must touch the face totally, not only small part of it keeps working.
3) For the eye, the operation way is advised to make circles.
Second Step: V-02 Four-Polar RF (15 Minutes)
n Function:
Four-Polar’s key advantage is that it utilises 4 electrodes to allows for greater focusing of the RF energy and a broader RF wave density which means that it can achieve variable depths of penetration into the target tissue being treated. Collagen in the tissue is heated and stimulated to create an immediate visible contraction and lifting effect, followed by remodelling with new and accelerated collagen production in the deeper layers over time
Usage
1) After first step, apply more cream or oil on the skin to make it moisten
2) The Four-polar RF probe must touch the skin firstly, then move the probe around and adjust the energy. The Energy should be adjusted slowly from low to high level until the customer feels comfortable
3) The headpiece can not leave the customer's skin, and can not stay in the same position. It must be moved around on the face during the whole operation process.
4) The headpiece must touch the face totally, not only small part of it keeps working.
5) This probe is for face lifting and sculpting use. please move the treatment head and lift the facial skin base on the facial lines.
Third Step: V-03 LED mask (10 Minutes )
Function:
With LED Red light and Infrared light therapy. It can encourages collagen and elastin regeneration by stimulation fibroblast activity in the skin. It also helps to increase blood and oxygen flow to the skin and capillaries, therefore increasing cellular metabolism and strengthening the capillary walls
Usage:
1) Before using the mask, please clean your face and the Uniform light membrane
2) Applying a serum, essence or moisturizer on the face, Use eyes patch or cotton to cover the eyes, then connected the uniform light membrane to the Mask. Then put it to the face. (if using the silk facial mask or Nonwovens facial mask, no need the uniform light membrane )
3) use the straps to fasten the mask
4) Adjust intensity base on the customer’s needs, usually we will suggest 4-5level, Treatment time: 10 minutes.
5) After treatment, please clean the membrane with water, and wipe down the Mask with Alcohol Pad,
Attention:
The LED MASK TREATMENT, WE will suggest the treatment time is 10-15 minutes a day; interval time is not less than 8 hours for the second treatment
Notice: The operation time is decided by professional beautician according to the different skin type of the customer. It is advised to do the operation 10-15 minutes for each probe.
8. Course of treatment:
12times a course:
Treatment period: 3 days/time, total 7 times
Consolidating period: 5 days/time total: 5 times
Clinical trials