Multifunctional hair removal IPL E-light Permanent Hair Removal,IPL Depilation Machine
USD $100 - $3,000 /Piece
Min.Order:1 Piece
Guangzhou Jimy Facial & Hair Beauty Products Co., Ltd.
L-13 Multifunctional hair removal IPL E-light Permanent Hair Removal,IPL Depilation Machine For IPL Depilatory Pigment Removal
For your safety the designers and manufacturers of IPL Hair Removal & Skin Rejuvenation System tried every means to avoid the strong light hurting people and environment.
Therapeutic theory
Tender skin:The strong Pulse multi-wavelength wide-spectrum colorful light irradiates the surface of skin directly acts on the abnormal pigment under skin and target tissue in blood vessel breaks down the irregular pigment cells closes the abnormal capillary vessel At the same time strong pulse light will be absorbed by the moisture in collagen and the thermo-effect will stimulate the hyperplasia of collagen so as to strengthen the elasticity of tender skin and remove wrinkles
Denuding:Strong pulse light with specific wavelength irradiates hairs and is absorbed selectively by hairs and hair follicles The skin gets high temperature instantaneously and the hair follicles putresce while keep normal skin and sweat gland in good state.
7. Adapting range:
Tender skin: freckle age pigment sunbur inor wrinkle crassitude pore dilation of capillary vessel acne etc.
Denuding:hair on lip beard armpit hair body hair etc.
8.Primary Technical Parameter.
Optical Source | Strong Pulse Light |
Standard Header Therapeutic Equipment | 430530640nm - 1200nm |
Transmission System | Sapphire crystal light-transmitting system |
Energy Density | 1-50J |
Width of Pulse | 1-40ms |
Repetition Frequency | 1P/1S |
Facla | 10 mm x30mm |
Coolant System | Cooling By Touch Approximately 4 centigrade |
Dimension | 45cmx45cmx30cm |
Weight | 30kg |
Power Supply | AC220V/5A 50Hz or AC110V/60Hz |
9. Characteristics of Photons Tender Skin
Treat the face and change the status integrally; denude thoroughly and no rebounding; quick safe little suffering the operation takes little time and dosen’t affect regular work Easy to learn to control and strict in quality the machine is in steady state
10.How to Use
Temperature 10°C-30°C
Relative humidity 40%-60%
IPL oparation Manual
oporation introduction-1.
(Pic.1)
Turn on the power, and a picture will turn out on the screen (pic.1) it takes about 2 seconds to enter into the treatment program platform.
1. treatment program platform
(Pic.2)
After entering into the treatment program platform(pic.2) press up and down to choose haie-removal or skin-rejuvenation treatment Press "ENTER"and the system will automatically choose the responding lighthandle On the other hand we can press "SIMM"first to light the lighthandle and then choose the treatment program Press ‘MEUN’to enter into the system setting,where we can have more treatment modes
recharge
After choosing the treatment mode, press ‘ENTER’ to recharge(pic.3). when recharging finished, the system will automatically enter into the treatment platform(pic 4).
2 1treatment platform
(Pic.4)
After entering into the treatment platform, we can chang the treatment parameters to adjust to the treatee. Press ‘SIMM’ to draw back from the treatment platform and turn out the lighthandle. Press ‘ENTER’ to draw back to the treatment mode menu to choose other treatment mode.
Lighthandle window: show the working treatment mode and the type of lighthandle.
Energy window:show the degree of the energy of the lighthandle.
Treatment parameters: show the parameters of the working treatment
Tips window: tips of function of the button.
change the parameters
(Pic.5)
Changes of the treatment parameters can change the energy emitted by the lighthandle, flency and flences, and to satisfy the needs of different treatment modes.
adjustable treatment parameters: (pic 6)
Energy output: energy can be changed directly during the treatment procesure from 0 J/cm2 to 50J/cm2 , showed in the energy window. Press up or down to increase or reduce the energy. Press them for seconds to speed the adjustment.
Cycle of Pulse: 1,2,3,4s.
Numbers of Pulse: 1-6pcs/s
(First Pulse)Time1: 1-10ms,
Dalay 1:1-100ms.
(Second Pulse)Time2 :1-10ms
Dalay 2:1-100ms
(Third Pulse)Time3:1-10ms
Press or to change the parameters.
On the treatment platform, press ‘MENU’ to ernter into the parameter menu. Press ‘MENU’ to select the treatment parameter options. Press up or down to change the parameters and up for increase and down for reduce. Press ‘ENTER’ to draw back from the parameter menu and to the treatment menu.
Pulse
(pic.6)
treatment
(Pic.7)
After recharging wait for about 10 seconds and the temperature of the lighthandle is reduced and it’s time to start treatin Press on the "work button" on the lighthandle and the tips zone shows"working" At the same time the lighthandle can start working according to the parameters Any botton is unavailable when the "work button" is pressed on During the treatment parameters can be changed After treatment press "SIMM" to draw back from the treatment and turn out the lighthandle and back to the treatment menu.
4. reset and check the parameters
On the treatment menu platform press "MEUN"to enter into the functional parameters platform(pic.8). press or to select the parameters and press "ENTER" to change the function option. Press ‘MEUN’
to draw back from the functional parameters platform to the treatment mode platform
system function setting
language Chinese or english
botton sound on or off
energy adjustment sound on or off
System clock press "MEUN" to enter into the adjustment. Up for hour and downfor second adjustment"ENTER" for confirm the adjustment.
Save setting save the system settings and back the main platform.
14. Contact Us Note
The lifespan of the treatment handle one standard treatment handle can shot 20 000 times.
After shooting 20 000 times, the effect of the pulse light might reduce. The treatment handle getting 20 000 times is out of the service guarantee and need change new treatment handle.
Skin-test (Essential)
Skin test is essential before the treatment for the safety operation The details is as following:
1) Skin test should be performed before the treatment for the client when the first time The test patch should be under the ears or other skins not influencing the facial beauty.
2) Clean the test patch with pure water and wash- milk apply a layer of cold coupling gel at the test patch Take the treatment handle from the
3) supporter and direct the light guide to the test patch Trigger 2-3 shots (1/3 area of the spot size overlapping the treatment site is permitted.) and wait for 2-3 minutes to examine the test patch:
4) For hair-removal with the Hair-removal treatment handle (630-1200nm wavelength)
5) First cut off the hair and leave only 1-2 mm Clean the test patch with pure water and apply a layer of cold coupling gel at the test patch Take the treatment handle from the supporter, and direct the light guide to the test patch. Trigger 2-3 shots (1/3 area of the spot size overlapping the treatment site is permitted) and wait for 2-3 minutes to examine the test patch
Shipping Way:
FEDEX,DHL,TNT,UPS,etc