Open cup fully automatic type flash point tester, fire point tester Quality Choice
USD $1,500 - $2,850 /Set
Min.Order:1 Set
Chongqing Assen Power Equipment Co., Ltd.
Low power consumption distribution transformer oil testing equipments Quality Choice
Digital display high precision transformer oil dielectric strength testing meter
ST series automatical type insulating oil breakdown testing instrument
High precision karl fischer titrated instrument,oil water detecting equipment
Flash Point is the lowest temperature at which a liquid can form an ignitable mixture in air near the surface of the liquid. The lower the flash point, the easier it is to ignite the material. Nowadays, Flash point is used to say non-volatile or flammable substances whether exit highly volatile or flammable substances, and has been one of the most important parameters for petroleum products transportation, storage, operations, safety management.
AC-S Open cup flash point tester is designed and made as per the National Standard of People’s Republic of China GB/T261-2008;GB/T21615-2008 & GB/T267- 88; GB/T 3536-2008;European standard;ASTM-D92;ASTM-D93, it is an advanced analytical instrument, mainly used to determine the open and closed flash point of petroleum products. With standardmodular design, a hostcan control thenumber ofopenorclosedtest furnace, be flexibleheaterswhilesharingthe same or differentsamplestesting,and be freelyexchangedbetweenthe testfurnaces, Normal control one to three test furnace at the same time.
1.standardmodular design, one main engine can control thenumber ofopenorclosedtest furnaces, be freelyexchangedbetweenthe testfurnace, According to user needs, , greatly improving the efficiency and economic benefits;
2.High-speed signal processor controlled, high-precision analog / digital converter circuit, the instrument is reliable and high precision;
3. Auto-ignition.
4. Automatic measurement of atmospheric pressure and automatic correction;
5. Adaptive PID control algorithm to automatically adjust the temperature according to standard curve
6. Detection, opening the cover, ignition, alarm, cooling, printing, auto-complete the entire experiment.
7. Automatically stop detecting the temperature value and alarm
8. Thermal micro-printer, making printing more efficient and more beautiful, with off-line printing;
9. save time time stamp & record test results automatically, store up to 256 data
10. Large screen with 320x240 graphical LCD display, showing a rich, full character display, touch screen operation, friendly interface; The screen saver function, extend the life of the LCD;
11. Interface, RS232 interface for printer or downloads on PC
AC-S open cup fully automatical flash point tester is mainly used to determine the open and closed flash point of petroleum products. With standardmodular design, a hostcan control thenumber ofopenorclosedtest furnace, be flexibleheaterswhilesharingthe same or differentsamplestesting,and be freelyexchangedbetweenthe testfurnaces, Normal control one to three test furnace at the same time.
AC-S Open cup flash point tester's technical Data:
| Closed Cup Flash Point Tester | Open Cup Flash Point Tester |
Temperature Range | -59.9°C~299.9°C | -59.9°C~399.9°C |
Control Temperature | ambient…+299.9°C | ambient…+399.9°C |
Repeatability | 0.025X(x=twice successive test average value) | Flash Point(°C) Error ≤150°C 3°C ≥150°C 5°C |
Resolution | 0.1°C | 0.1°C |
Temperature sensors | Level A; PT100 | Level A; PT100 |
Flash Sensor | Thermocouple | Thermocouple |
Power Supply | AC220V ± 20% ; 50HZ ± 10% | AC220V ± 20% ; 50HZ ± 10% |
Power Consumption | approx 400W | approx 400W |
Operational Temp | 0 ~ 40°C | 0 ~ 40°C |
Operating Humidity | ≤ 85% RH | ≤ 85% RH |
Open cup flash point tester's Structure Chart:
Q: What is BDV test for distribution transformer?
A: When you say BDV you might mean the dielectric strength of transformer oil. A new transformer oil should have at lest a dielectric strength of 39 KV. from a British standard.Transformer oils used are normally tested using ASTM D877-82 with the KV strength tester using 1" electrodes spaced 0.1" apart and the test voltage increased at 3,000 volts/min until it breaks down. The average Kv obtained after 8 trials is considered the Oil dielectric strength.
Using this test method,dielectric strength at 30 kv and above is considered good. Dielectric strength between 23 to 29Kv is considered usable, but requires filtering. Below 23 kv, the transformer oil should be replaced. Another method ASTM D18747-82 uses the small radius electrodes but spaced only .o4 inches. The test voltage is 500volts/min and increased until breakdown. The dielectric strength is still the average Kv obtained in 8 trials. The dielectric strength of 28-29Kv is considered good. Below 28 kv, the transformer oil is usable but requires filtering. The latter method is considered a better test method.
Chongqing Assen Power Equipment Co.,LTD, which is professional in design, manufacture, sale of oil purification equipment, relevant testing instruments and provide comprehensive filtering solution, owns advanced production lines and sophisticated detection equipment, first-class R & D staff , professional workers and High-quality sales and service teams
Our Product: Double Stage Transformer Oil Purification system, Vacuum Lubricating Oil Purification, Vacuum Turbine Oil Conditioner, Portable Oil Purifier, Singe Stage Insulating Oil Purifier, Water Oil Separator, Light fuel Oil Purifier, and Fully-auto Dielectric Oil Tester, Turn ratio Tester, Acid Tester, Moisture Detector, Interfacial Tension Tester, etc.
Our Service: special filter technology consulting and solutions sector; fast after-sale service feedback system, well-trained service engineer; hands-on training and large-scale equipments operation myrmidon; regularly visit system, CRM customer relationship management system; rapid Filter wearing parts and spare parts supply system.
We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!