The OPTITEMP TRA/TCA-S11 is a temperature assembly without the neck tube. It is predominantly used in the lower temperature range (up to +150degC / +302degF). When it features a neck tube, spatially separating the process connection from the connection head, the connection head cannot heat up as much. This is particularly important when there is a temperature transmitter in the connection head.
Design: DIN-style, welded, multipart thermowells
Process connection: threads: G 1/2, G 3/4, G 1, 1/2" NPT and 3/4" NPT
Neck tube connection: without neck tube
Tip design: straight tip
Diameter: diameter 9, 10, 11 and 12 mm
Features
:: Temperature range from -200degC to ≤ 600degC, depending on the load
:: Different heads available, IP54 to IP68
:: Optional head mounted transmitter
:: Spring loaded mineral isolated RTD or TC insert
:: Inserts sheath material 316 L or Inconel 600
:: Standard and customised length
:: Ex Approvals:
- ATEX II 1G Ex ia IIC T6 Ga
- ATEX II 1/2G Ex ia IIC T6 Ga/Gb
- ATEX II 1D Ex ia IIIC T145degC Da IP65