six in one multi-parameter Water Quality Monitor

six in one multi-parameter Water Quality Monitor

USD $120 - $140 /Piece

Min.Order:1 Piece

Supply Ability:
300 Piece / Pieces per Month
Port:
Shanghai or Ningbo
Payment Terms:
T/T Credit Card PayPal

Quick Details View All >

Place of Origin:
Zhejiang, China
Brand Name:
LOHAND
Model Number:
PHT-027

Hangzhou Lohand Biological Co., Ltd.

Business Type: Manufacturer,Trading Company
Hangzhou Zhejiang China
Main Products: PH meter ,refractometer ,test paper ,TDS meter ,ORP meter

Product Details

 

Product Description

 

six in one multi-parameter Water Quality Monitor


 

 

PHT-027multi-parameter Water Quality Monitor


This monitoris a member ofthe line of qualitymonitors availablefrom ours.
The ContinuousMonitor Seriesfeature microprocessor technology, which gives itmany reliable,user-friendly features.These monitors were designed forlong-term low-maintenance use, justplug inthe  AC adapter, calibrate andthe unit is ready for continuous monitoring. Itincludes therechargeable batteries. It can insure working when powercut.



Specifications
Range:
EC: 0.00 19.99EC                        PH: 0.00 14.00PH
CF: 0.0 199.9CF                           mV: 0~ 1999mV
TDS: 10 ~19990ppm                    Temp:    -50~ 70 ( -58 ~158 )

Operating Information
1. Connectthe power adaptor tothe power supply outlet.
2. Connectthe pH or ORP electrode tothe probe inset of the instrument.Remove theprotective cap.
3. Turn onthe meter .
4. Immersethe electrode in the solution tobe tested.Stir gentlyand wait for the reading to stabilize.
5. Pressthe " / " key , choice the  / for measuring. Press the"EC/CF/ppm " key, choice inturn show EC, CF , TDS for measuring.
6. Whenyou connectthe ORP electrode, Pleasepress the"MV" key . It will showthe ORP value.
7.  After use,turn off the meter . Rinse the electrode with tapwater to minimize contamination.Replace theprotective cap.

 

Calibration
1.PH Calibration
Pour asmall quantityof pH6.86,pH4.01and pH9.18solution into clean beakers.
For aparticularly accuratecalibration, itis advised to use two beakers for each buffer solution; the first is to be usedfor rinsing the electrode,the second is to be usedfor the calibration. Inthis way , the risks of contaminating thebuffer solution are reducedto a minimum.Connect thepower adaptor.Turn on the meter .The calibrationof theinstrument's pH range is now complete.
Immerse the ph electrodein pH 6.86 buffer solution, andgently shakeit.Allow thereading to stabilize andwith thesupplied screwdriver, adjust the "pH6.86" calibration trimmerto read "6.86"pH. Rinse the electrode with distilledwater,and suckit with filter-paper.Immerse the ph electrodein pH4.01 buffer solution, and gentlyshake it.Allow thereading to stabilize andwith thesupplied screwdriver, adjust the "pH4.01" calibration trimmerto read "4.01"pH. Rinse the electrode with distilledwater,and suckit with filter-paper.Immerse the ph electrodepH9.18 buffer solution untilthe display shows"9.18".

 

2.EC CF ppm Calibration
Press the" EC/CF/ppm " key . Choice the "EC" for operating. Immerse the meter in 12880 s/cm(12.88EC) calibrationsolution.
Immerse the meter in1413 s/cm(1.41EC) calibration solution.  

 

Important:Notice
Stir gentlythe meter when using.Don't letsome blebon theelectrode.In case of abnormalphenomena suchas highmeasured deviation,blinking measuredvalue, nozero resetting,etc, pleaseimmerse the electrode inalcohol forcleaning.If the protection caphas beenwithout electrolyte,or ifthe electrode has notbeen usedfor a long time, the electrode must bereactivated by leaving it for several hours ina beakercontaining normaltap water .When withoutusing poweradaptor,If the meter cannot beswitched on
or thedisplay fades.Please connectthe power adaptor tothe power supply outlet.It will charge upthe rechargeable battery. Andit also works on.

 

Warranty
These instrumentsare warrantedfrom all defects inmaterial and manufacturing fora periodof oneyear fromthe date of purchase.
If during this period, the repair or thereplacement of parts isrequired where thedamage isnot dueto negligence or erroneousoperation by user,please returnthe parts to either dealer orour offices, and the repair will be effected free of charge.
Allow thereading to stabilize andwith asmall screwdriverturn the CAL calibration trimmeruntil thedisplay shows"12.88EC". Rinse the electrode withdistilled water, and suck itwith filter-paper. until the display shows "1413(1.41EC)".The instrument'srange must be re-calibratedwhenever:The electrodehas beenused(laid) forlong time from the last calibration.The electrodehas beenused inparticularly taxingconditions.The utmostaccuracy isrequired.

Packaging & Shipping

The normal package is carton box,it also can be packaged according to customers special request.

Our Services

We have experienced and dedicated core members to offer you professional and reliable before-sales and after-sales service.

Company Information

 Hangzhou Lohand Biological Co.,Ltd is a professional company that manufactures and exports laboratory instruments and equipments.We have our own registered brand"LOHAND" and own factory,with strong R&D center,sales team,customer service team and QC team,which grows very fast and obtains good reputation in the markt.

 

Our major products include: Refractometer,Test paper,pH meter,Electrode,TDS meter,Salinity meter, DO meter,ORP meter,Conductivity meter,Turbidity meter,Color comparison tube,test kit etc.Most of the products have CE certificate.All products can be customized according to buyers' special requirements.

FAQ

Q1: Why choose us?
A: 1. We have our own factory with strong R&D center and QA team which can make sure your goods can be sent out on time and in superior quality.
2. We have experienced and dedicated core members to offer you professional and reliable before-sales and after-sales service.
3. We have purveyed customers with the lowest wholesale price.

Q2: How do you guarantee the quality?
A: One year's guarantee from date on B/L. Normally. If it's quality problem, we promise to return goods or funds.

Q3: Is OEM available?
A: Yes, all goods can be custom made by your requirements, including packing, LOGO print, etc.

Q4: Can we buy 1 pc for sample testing?
A: Yes, we are glad to send 1pc for quality testing if we have stock of the model you required.

Q5: How to deliver the goods for trial order or small order?
A : For small order, we prefer to choose international express, such as DHL, TNT, EMS which are faster and more convenient for customer. Also, we cooperate with an express agent that can give us a big discount for express fee which is much lower than that quoted by official. For the goods with detachable battery, the express fee can be lower down if the goods is sent out without battery.

Q6: What kind of payment your company accept?
A : T/T , WEST UNION , PAYPAL , ETC.

Q7: If we have not found the model from website, what should we do?
A: Please email us with description and picture of the product, we research and develop new model every month, and some of them maybe have not been uploaded in website immediately. But If this is a new products for us, we can develop it for you after get all detailed information about your product.

Contact Supplier

Mr. Mike Zhang Deputy General Manag Chat Now
Telephone
86-0571-86418090
Mobile
13732228065
Fax
86-0571-56515259
Address
Floor 2, Bldg. 5, Jianggan Tech Park, No. 63, Jiuhuan Road, Jiubao Town, Jianggan Dist, Hangzhou,Zhejiang

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Analyzers > PH Meters
Categories
Hi~