laboratory instrument chargeable combination pH electrode

laboratory instrument chargeable combination pH electrode

USD $18 - $22.5 /Piece

Min.Order:100 Pieces

Supply Ability:
5000 Piece / Pieces per Month
Port:
Fob Shanghai or Ningbo
Payment Terms:
T/T Credit Card

Quick Details View All >

Place of Origin:
Zhejiang, China
Brand Name:
Lohand
Model Number:
E-201-F

Hangzhou Lohand Biological Co., Ltd.

Business Type: Manufacturer,Trading Company
Hangzhou Zhejiang China
Main Products: PH meter ,refractometer ,test paper ,TDS meter ,ORP meter

Product Details

Product Description

 

E-201-F pH ELECTRODE MANUAL                        

Introduction

Laboratory PH combination electrode consists of a measuring electrode and a reference electrode.

Technical specifications

Product name:           pH Electrode

Model:                  E-201

Measuring range:        (0-14)PH

Temperature:            (0-80)°C

Theoretic percent slope:   ≥97%     (25°C)

Zero point PH value:      (7±0.25)PH  (25°C)

Inner impedance:         ≤250MΩ    (25°C)

Response time:           ≤1 minute

Alkaline error:             ≤15mv     (25°C)

Operation & maintenance

1. Before in use, the electrode should be calibrated by standard buffer solution with known PH value. In order to improve the accuracy of the measurement, PH value of the buffer of the measurement, PH value of the buffer solution should be reliable and as close to PH value of   sample solution as possible, within 3 PH units normally.

2. The sensing glass bulb in the tip of the electrode can not touch with hard materials. Any damage or scratch will result in the failure of the electrode.

3. BNC socket is adopted. It must be kept clean and dry. If there is any contamination, use absorbent cotton and absolute alcohol to clean and air dry. Absolutely prevent it from short circuit of the output end, otherwise the measurement will be incorrect and disabled. Before the electrode with temperature compensation in use, insert the plugs of BNC and NTC respectively in the correspondent sockets on PH meter.

4.The protective cap is filled with certain electrolyte solution to wet the tip of the electrode and to activate the glass bulb & liquid junction. If it is dried, fill in the solution or distilled water.                                                 

5.The making of the filling solution:

take one pack ofpH4.00 buffer reagent , dissolve it into 250mI deionized water and add 56g potassium chloride(analysis pure grade), heating for some time and agitating to have it dissolved completely.

If the electrode needs to be activated in a shoatime,3.3M potassium chloride solution could be used also, the making Of this solution is:

take 56g potassium chloride (analysis pure grade)and dissolve it into 100ml deionized water

6.Make sure that air bubbles in the glass bulb should be removed before in use.

Otherwise it will lead to measurement error.

The electrode should be Stirred in the sample solution for a while and then stopped so as to shorten the response time

7. Before and after the measurement.

The electrode should be cleaned by deionized water to make sure the accuracy of the electrode. When the measurement is finished in viscous solution,remove the protective cap firstly and clean the electrode repeatedly so as to remove the sample solution which adheres to the glass membrane.

Or use a suitable solvent to clean the electrode firstly and then deionized water.

 

8.The electrode should not be immersed into distilled water, or protein solution and acid fluoride for a long time,and prevent it from contact with organic silica grease.

9.The life of the electrode is about one year, when it is aging,replace it with a new electrode.

 

Application

Suitable for aqueous media in lab in general,water-based emulsion, water-based suspension, paintings and water-based inks,in aquariums, waste water treatment, field measurement, swimming pool and etc .

 

Company Information

 

 

 

FAQ

 

Q1: Why choose us?

A: 1. We have our own factory with strong R&D center and QA team which can make sure your goods can be sent out on time and in superior quality. 

2. We have experienced and dedicated core members to offer you professional and reliable before-sales and after-sales service.

3. We have purveyed customers with the lowest wholesale price.

 

Q2: How do you guarantee the quality?

A: One year's guarantee from date on B/L. Normally. If it's quality problem, we promise to return goods or funds.

 

Q3: Is OEM available?

A: Yes, all goods can be custom made by your requirements, including packing, LOGO print, etc.

 

Q4: Can we buy 1 pc for sample testing?

A: Yes, we are glad to send 1pc for quality testing if we have stock of the model you required.

 

Q5: How to deliver the goods for trial order or small order?

A : For small order, we prefer to choose international express, such as DHL, TNT, EMS which are faster and more convenient for customer. Also, we cooperate with an express agent that can give us a big discount for express fee which is much lower than that quoted by official. For the goods with detachable battery, the express fee can be lower down if the goods is sent out without battery.

 

Q6: What kind of payment your company accept?

A : T/T , WEST UNION , PAYPAL , ETC.

 

Q7: If we have not found the model from website, what should we do?

A: Please email us with description and picture of the product, we research and develop new model every month, and some of them maybe have not been uploaded in website immediately. But If this is a new products for us, we can develop it for you after get all detailed information about your product.

Contact Supplier

Mr. Mike Zhang Deputy General Manag Chat Now
Telephone
86-0571-86418090
Mobile
13732228065
Fax
86-0571-56515259
Address
Floor 2, Bldg. 5, Jianggan Tech Park, No. 63, Jiuhuan Road, Jiubao Town, Jianggan Dist, Hangzhou,Zhejiang

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Analyzers > Other Analysis Instruments
Categories
Hi~