SS-EFT for Huawei Optix Metro 500
USD $1 - $1,000 /Piece
Min.Order:1 Piece
Shenzhen Hua Jiahui Technology Co., Ltd.
The release notes describes the update information of the OptiX Metro 500 NE Software (NE5.24.04.10P02), including its principal functions and operations.
n Product name: OptiX Metro 500
n Software version: NE5.24.04.10P02
Table 1 shows the NE and the network management (NM) software of the OptiX Metro 500.
Table 000011 NE and NM software configuration table
Software type | Version |
NE (terminal) software | NE5.24.04.10P02 |
NM software | iManager T2000 V200R001C03 |
Table 2 shows the NE and board software configuration.
Table 000012 NE and board software configuration table
Board type | Board name | Issue No. of new software |
Data characteristic board | SS42ET1D | V130 |
Note 1: The software of the line and tributary boards of the Metro 500 is integrated in the NE software of the FSCC board. So it does not need independent board software.
In V100R004, the software of the ET1D board is independent. It is used with the NE software to support the access of data.
Table 3 shows the OptiX Metro 500 board software configuration.
Table 000011 Board software configuration table
Board type | Board name | Board software version | Board logical version No. | Board BIOS No. |
ISU | SS42ISU | 5.24.04.10P02 | FPGA:V210 | Nebios:8.02.06 Extbios:9.02.02 |
SS43SU | 5.24.04.10P02 | FPGA:V110 | Nebios:8.02.06 Extbios:9.02.02 | |
Data characteristic board | SS42ET1D | V130 | CPLD:V100 FPGA:V100 | V110 |
SS42EFT | None | CPLD:V100 | None |
NE5.24.04.10P02 supports the OptiX Metro 500 V100R004, the OptiX Metro 500 V100R002C02, the OptiX Metro 500 V100R002 and the OptiX Metro 200 V100R001. By presetting the type of equipment, you can select what functions are contained in this NE software. You can preset device-type to the OptiX Metro 500 or the OptiX Metro 200. On the basis of the previous versions, V100R002C02 adds CAU and transparent transmission of network management (NM) information (V5) through the serial port. The V100R003 adds the EFT board, and report of T1AIS alarms of the PM1 boards. The V100R004 supports System Self-test, 2M Pseudo Number test, improvement the Single Station Data Backup of Web Lct, Soft Tools of test Single Station, PS Alarm switching process and improvement of SNC protocol, the Form of return the Command Line is: basic ID + extended ID, supports inquire all of the Impedance of Tributary Card from Network, the Attribute of Single Byte DCC, supports Step-down Switching in SSM Mode and E3/T3 board.
In NE5.24.04.10P02, the OptiX Metro 500 NE software has the following features:
Note:
(*) means it is the special functions for the OptiX Metro 500 preset to be of V100R002.
n Managing modules, memory and tasks.
n distributed loading of NE software.
n uploading and downloading hardware manufacturing information.
n loading FPGA and extended BIOS to the FSCC board.
n presetting the type of equipment.
n configuring NE ID and extended NE ID.
n Embedded control channel (ECC) communication.
n Ethernet communication.
n Communications through the serial port (used to access the NM system, command line, transparent transmission of the NM information and the CAU board).