High Frequency Mobile C-arm System AJ-112E (Small C Arm System)
Negotiable /Set
Min.Order:1 Set
Anjue Medical Equipment Co., Ltd.
High Frequency Mobile C-arm System
(Small C Arm System)
Usage
Orthopedics: restore bone translocation, reset, fixing
Surgery: taking foreign bodies out of the body, cardiac catheterization, implantable pacemakers, some of angiography and local photography etc.
Features
1. New integrated design of TV system and mainframe, it does not need to connect electric cable, so the operation is more convenient.
2. High-quality combined HF-HV X-ray generator with our high voltage cable, it reduces loss and the quality of x-ray and image are good.
3. Electric rotating lead piece iris beam limiting device, it can satisfy multi-angle and multi-direction anatomical display.
4. The machine adopts imported image intensifier, matching with high-definition and high-resolution CCD and progressive scan display system, which matches with image system better.
5. With the perspective KV, MA automatic tracking feature, the image brightness and definition are automatically set at optimal function.
6. Graphical colorfully LCD touchable screen console interface, the operation is convenient and intelligent.
7. Unique hand-held remote controller, the doctor can operate it a far distance, so it’s more convenient.
Standard Configurations
1. New integrated C-arm mainframe 1set
2. Combined high-frequency high-voltage X-ray generator and high-frequency power supply (5.0kW, 40 kHz, 120kV) 1 set
3. Imported 9 inch image intensifier 1 set
4. Imported ultra-low illumination CCD radiography 1 set
5. High-definition progressive output CCU control system 1 set
6. Imported dense grain grids 1 set
7. Electrical adjustable beam limiting device 1 set
8.14-inch high-definition medical dedicated monitor 1 set
9. Unique hand-held controller 1set
Specifications
Category | Items | Content | |
Model | AJ-112E | ||
Electrical Performance | High frequency inverter power supply | Power:3.5KW | |
Automatic fluoroscopy | Tube voltage :40 kv~120kv Tube current: 0.3mA~~4mA | ||
Manual fluoroscopy | Tube voltage :40 kv~120kv | ||
Pulse fluoroscopy | Tube voltage:40 kv~120kv, continuous | ||
Photography tube voltage, tube current mAs | 40KV~120KV, 20~100mA , 1~180 mAs | ||
X-ray Tube | X-ray tube special for high frequency | Large focus:1.5,Small focus :0.3 Thermal capacity: 650kJ (867 kHu) | |
Imaging System | Image intensifier | Imported TOSHIBA 9 inch image intensifier | |
CCD photography | 470,000 Pixel | ||
Monitor | 1 sets of 14 inch High definition medical CRT | ||
CCU (central control) | HD progressive output, continuous adjustable recursion, many images storage, upright image, horizontal image, positive & negative image, image patching, LIH(last image freeze), OSD (monitor display). | ||
Structure and performance | Direction wheel and main wheel | Direction wheel can rotate in any direction, and main wheel can rotate in ±90°. | |
C-arm | The up and down electrical stroke of pillar is 400mm. | ||
Plate holder size | 200mmx250mm(8”x10”) or 250mmx300mm(10”x12”) |