digital x-ray machine prices/300m X-ray Machine

digital x-ray machine prices/300m X-ray Machine

USD $800 - $1,200 /Piece

Min.Order:1 Piece

Supply Ability:
2000 Piece / Pieces per Month
Port:
SHANGHAI/SHENZHEN/GUANGZHOU
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Type:
Other, Oral Therapy Equipments & Accessories
Brand Name:
ANJUE
Model Number:
AJ-4301
Place of Origin:
China

Anjue Medical Equipment Co., Ltd.

Business Type: Trading Company
Anqing Anhui China
Main Products: Anaesthesia machine ,Ventilator ,Medical Sterilization Packaging ,Syringe Pump ,Hemotology Analyzer

Product Details

Specifications

1.digital imaging system of mouth
2.ight touched button
ntrolled with microcomputer
Type: dental x-ray machine

Category  Product NameModel No.
X-ray Machine  Mobile X-ray Machine 50mA AJ-50IIA
Mobile X-ray Machine 100mA AJ-100BY
X-ray Machine 200mA AJ-4104
X-ray Machine 300mA AJ-4106
Portable X-ray Machine AJ-4301

1. 50mA Mobile X-ray Machine AJ-50IIA

digital x-ray machine prices/300m X-ray Machine

This X-ray machine features full wave rectification and modular X-ray tube head. The frame of the unit, of cantilever construction, is compact in design easy of movement. The machine can be used for radiography in hospital wards or operating rooms.
 Specifications
1. Power requirements
  Voltage: 180-240V Frequency: 50Hz
  Internal resistance: ≤1ΩRating:5k VA
  Current: Maimum15A for radiography
2. Time: 0.08 to 6.32 steps electronic
3. Maximum height from X-ray tube focus to floor>1820mm
4. Minimum height from X-ray tube focus to floor<550mm
5. Collimator: Maximum film size at 1000mm
  Focal distance: 430×430mm
6. Maximum remote control distance: 6m
7. X-ray tube focus 2.3×2.3
8. Unit moving force  <5kg
9. Net weight of the unit 90kg

2.100mA Mobile X-ray Machine AJ-100BY

digital x-ray machine prices/300m X-ray Machine

Take x-ray photography of the head, extremities, chest cavity & other parts of human can be used in the ward or in operation room.

Features
1. Single focus, full-wave rectifier, combined X-ray generator
2. SCM control (easy to maintain and repair)
3. High visual and operational console with LCD monitor
4. Presorted 8 kinds of photography parameters 
and select, modify, store the parameters under 
the condition of choice
5. Power voltage (V), photograph kilovolt (KV) 
infinitely variable control 
6. Premier high voltage with high power SCR zero control circuit 
7. Function of load chains, exposure time control, auto alarm, preheat filament,
subassemblies’ temperature control, and so on 
8. Cantilever structure makes the small volume and easily moving 

 

3. 200mA X-ray Machine AJ-4104

digital x-ray machine prices/300m X-ray Machine
Usages
General Photograph
Ray-filter Photograph
Features
1. Single bed and single bulb
2. Design according to the electric mechanism of middle-size machine.The function is full and reasonable.
3. The high-tension system is of march-past structure. Equipped with full-wave rectification high-voltage generator and independent X-ray tube unit, this machine is with large output power and operation is reliable and stable.
4. Supply voltage V, roentgenoscopy, photography KV and step-less adjustable.
5. Equipped with the manostat for filament of X-ray tube and the space-charge compensator as to ensure the stable and accurate output.
6. Equipped with the capacity limitation and protection circuit and KvmAS interlock limitation and protection.
7. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly
8. High-voltage primary uses the zero controlled circuit of silicon-controlled rectifier of large power.
9. Photographic bed can move in length and breadth
10. The photographic bed, pillar & vibrating ray-filter are in a whole without top & bottom track.


5.300m X-ray Machine AJ-4106

digital x-ray machine prices/300m X-ray Machine
Usages
General Photograph
Ray-filter Photograph

Features
1. Single bed and single bulb
2. Design according to the electric mechanism of middle-size machine. The function is full and reasonable.
3. The high-tension system is of march-past structure. Equipped with full-wave rectification high-voltage generator and independent X-ray tube unit, this machine is with large output power and operation is reliable and stable.
4. Supply voltage V, roentgenoscopy, photography KV and step-less adjustable.
5. Equipped with the manostat for filament of X-ray tube and the space-charge compensator as to ensure the stable and accurate output.
6. Equipped with the capacity limitation and protection circuit and KvmAS interlock limitation and protection.
7. Adopt the digital circuit timer, grade according to R10 priority coefficient and can control time exactly
8. High-voltage primary uses the zero controlled circuit of silicon-controlled rectifier of large power.
9. Photographic bed can move in length and breadth
10. The photographic bed, pillar & vibrating ray-filter are in a whole without top & bottom track.

X-Ray tube model XD51-2040/125
focus small focus 1X1mm big focus 2X2mm
Photographic bed(YZ-I) Bed face(LXWXH) 2000X665X700mm
Moving range of bed face 640mm in length; 200mmin breadth
Ray-filter of bed Travel in length 500mm
Grid density N28
Convergence distance fo 100cm
Grid ratio R8
Pillar of X-ray source unit Moving in length along photographic bed 1800mm or 1600mm
Distance around as moving up and down(along upright post) 650-1800mm
Rotary around the center of cross arm ± 180°
Rotary around the shaft line of X-ray annular tubes -10 ° ~ 60° ~ +120°
Max size of cassette for photograph 356mmX432mm(14”X17”)
6.Portable X-ray Machine AJ-4301

digital x-ray machine prices/300m X-ray Machine

This machine is shock-proof, ray-proof, single focus and self-rectified x-ray unit.
It applies to medical fluoroscopy and radiography on mouth, cavity bone, heart, skull as well as contraceptive ring.

Main Specifications    
* Max fluoroscopy 75KVp 3-5mA (discontinuous use)
* Max radiography 75KVp 10ma 6sec (interval time 3minutes) (Routine fluoroscopy condition: 65KVp 3mA)
* Power Supply  220v±10% ,50hz,1KVA
* Current: For fluoroscopy 2a (discontinuous)
For radiography 6a (instantaneous)
* Size of screen  203mmx 254mm
* Range of movement  vertical: 220mm; horizontal: 130mm
* Tube turning angle: Vertical360, horizontal 320
* Volume: 50cmx 31cmx 18cm
* Weight: 25kg
Mammography X-ray Machine AJ-M030
Features
It is used to diagnose early mamma pathological changes.
Using the Mo. target X-ray tube can show the pathological changes details.
A nipple areola cuticles fat galactophore canals glandular tissue connective tissue and blood vessels can be seen in the picture.
It has high correctness for distinguishing benign tumor and malignant tumor.
It can be moved to sickroom to photograph beside bed.
The unit can also be used to find foreign matters in human body to do nondestructive inspection of right metal and nonmetal materials.

Main Technical Parameter
Main character Shockproof, single focus and full-wave rectification
Max rated capability Current 30mA
Voltage 34kVp
Time sec. 2s

 Power supply Voltage 180-240V
Frequency 50Hz
Power Not lower than 1.3VA
Range of the timer 0.4-2s
Film size 127mm x 178mm
   
The movement of camera head mounting Vertical movement range 630mm Adapt to different part of human
   
Transverse rotation    
±80°
The Camera Head Mounting horizontal range 160mm
Rotating angle of the module of the Camera Head Mounting and pole 180°


7.Vertical Bucky Stand AJ-LS

digital x-ray machine prices/300m X-ray Machine


AJ-LS Vertical Bucky Stand, which Bucky grid can move up and down, is a photograph device. It can be used as a photograph auxiliary device. It can photograph including Breast, Belly, Joint, the foot limbs so on.

Feature
Close Structure, small, and convenient for install
Easy to moved up and down, can lock freely by hand
The short distance from table to film can guarantee photograph high quality and little distortion
Support frame noiseless, cassette could push into directly, easy to operate
Fixed Bucky, no need of power(can also use electromotor oscillating grid)

Construct by
Stand, Adjust Frame and Bucky(fixed)

Specification
Vertical movements: >500mm~1600mm
Size of film: 203mm×254mm(8″×10″) ~356mm×432mm(14″×10″)

Fixed Bucky X-ray Grid Indexes
film: >15″×18″
40L/cm Density N : 40L/cm
Grid proportion r . 8. 1
Converging focus distance fo: 1800mm

Contact Supplier

Mr. Jonathan Dong General Manager Chat Now
Telephone
86-556-5836185
Mobile
13637160963
Fax
86-0556-5836179
Address
Building C3-13, Guangcai Business Garden Anqing,Anhui

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Dental Equipments
Categories
Hi~