2D Laptop Color Doppler iSpark 280
Features
- Electronic linear array/convex array/micro-convex/phased array scanning
- The dynamic color doppler (CFM), color doppler energy figure (CPD)
- Pulsed doppler (PW), continuous doppler (CW)
- The heart, blood vessel function measurement packages measuring software packages
- General adult and children the heart, diagnosis and treatment of abdominal, gynecology and obstetrics, urology, pediatrician, endocrine division, etc
- Peripheral vascular, small organs (breast, eye, esophagus, muscle, etc) transcranial, during, puncture, etc
- Single frame B/double frame B / 4 frame B, M or B + M, CFM + M, CFM + fig. 3 MCAO
- Digital transmit and receive imaging
- Automatic filter out the blood vessels color doppler spillover, make the image more realistic, and bright
- Improve the color doppler CFM and energy CPD sensitivity
- Complete control of the software beam-forming device
- Faster processing speed, more abundant information
- Organization secondary harmonic imaging
- Expand imaging
- USB interface, network transmission function
Technical specifications
Full-digital color ultrasound diagnostic system, the system has the ability to upgrade | |
Frequency Range | 2.0-14MHz |
Probe types | convex array, linear array, heart and cavity probes |
Display | B / M, B / D, B / CD, B / D / CD may be the same screen display, M type and scope of PWD icon size adjustable |
Frequency Probe Specifications | Abdomen convex array probe: 2.0 ~ 5.0MHz electronic convex array broadband probe frequency, the frequency range 2 - 5MHz, 3 selectable frequencies Bandwidth |
E-broadband frequency linear array probe, the frequency range 5 - 14MHz, scan angle: 60 degrees | |
Intracavity frequency convex array broadband probe, the frequency range 4 - 8MHz, scanning angle ≥ 135 ° | |
Optional pediatric cardiac probe, transesophageal probe, laparoscopic probe, tiny protruding array probe, intraoperative probes. | |
probe array element | ≥ 128 |
Image Mode | two-dimensional B-, M-type, pulsed PW , color CFM / power Doppler and direction of the Energy PDM |
B / D use either | B / PWD, B / CD / PWD three simultaneous display |
Digital full anatomical M-imaging techniques, the sampling line can be anywhere in the 360-degree range as the center of arbitrary sampling | |
Organization of second harmonic imaging, harmonic function ≥ 2 groups | |
B / M / CD can be adjusted independently | |
Resolution | Lateral ≤ 2mm, longitudinal ≤ 1mm |
detecting depth | ≥ 240mm |